Dell PowerEdge RAID Controller 11 User’s Guide PERC H755, H750, H355, and H350 Controller Series

Memory errors

Memory errors can corrupt cached data, so the controllers are designed to detect and attempt to recover from the memory errors. Single-bit memory errors can be handled by the controller and do not disrupt normal operation. A notification is sent if the number of single-bit errors exceeds a threshold value.

Multi-bit errors are more serious as they result in corrupted data and data loss. The following are the actions that occur in the case of multi-bit errors:

  • If a multi-bit error occurs while accessing data in the cache when the controller is started with dirty cache, the controller discards the cache contents. The controller generates a warning message to the system console to indicate that the cache was discarded and generates an event.
  • If a multi-bit error occurs at run-time either in code/data or in the cache, the controller stops.
  • The controller logs an event to the controller’s internal event log and a message during POST is displayed indicating a multi-bit error has occurred.
NOTE:In case of a multi-bit error, contact Global Technical Support.