Translation of ID to physical NVDIMM-N in host system can be seen below.
ID (Hex) | Decimal | Physical Location (L->R) | Silk screen slot name |
---|---|---|---|
0x1 | 16 | Socket 0 , IMC0, Channel 0 , Slot 1 | A7 |
0x11 | 17 | Socket 0 , IMC0, Channel 1 , Slot 1 | A8 |
0x21 | 33 | Socket 0 , IMC0, Channel 2 , Slot 1 | A9 |
0x101 | 257 | Socket 0 , IMC1, Channel 0 , Slot 1 | A10 |
0x111 | 273 | Socket 0 , IMC1, Channel 1 , Slot 1 | A11 |
0x121 | 289 | Socket 0 , IMC1, Channel 2 , Slot 1 | A12 |
0x1001 | 4097 | Socket 1 , IMC0, Channel 0 , Slot 1 | B7 |
0x1011 | 4113 | Socket 1 , IMC0, Channel 1 , Slot 1 | B8 |
0x1021 | 4129 | Socket 1 , IMC0, Channel 2 , Slot 1 | B9 |
0x1101 | 4353 | Socket 1 , IMC1, Channel 0 , Slot 1 | B10 |
0x1111 | 4369 | Socket 1 , IMC1, Channel 1 , Slot 1 | B11 |
0x1121 | 4385 | Socket 1 , IMC1, Channel 2 , Slot 1 | B12 |