Dedicated hot spare disk fails during rebuild

Issue:
A hot spare disk fails during rebuild while using a dedicated hot spare.
Probable Cause:
The dedicated hot spare assigned to the virtual disk fails or is disconnected while the rebuild is in progress.
Corrective Action:
If there is a global hot spare available with enough capacity, rebuild will automatically start on the global hot spare. Where there is no hot spare present, you must insert a physical disk with enough capacity into the system before performing a rebuild.