Dell Chassis Management Controller for Dell EMC PowerEdge FX2 Version 2.20 Release Notes

PDF

Error occurs while importing CMC configuration file

Description
An error occurs while importing CMC configuration file using local or remote RACADM.
Resolution
This issue occurs when IPv6 is enabled or disabled from the configuration file. Enable or disable IPv6 using the command, racadm config -g cfgIPv6LanNetworking -o cfgIPv6Enable 0.
Versions/Systems affected
CMC for PowerEdge FX2 1.10 or later