Manually configuring a Unity VMware VMFS datastore
About this task
NOTE If the VMware datastore is created in Unisphere, no additional action is required on the VMware side, the datastore will appear automatically. If a LUN is provisioned to the ESXi host, a datastore must be manually created on the VMware side.
Steps
Log in to the vSphere client as an administrator
Rescan for new storage devices:
From
Hosts and Clusters, select the server.
Select the
Configure tab.
Under
Storage, click
Storage Adapters.
Select the Fiber Channel adapter from the list of adapters.
Select
Rescan Storage....
Add each VMFS datastore to the ESXi host:
FromHosts and Clusters, select the host.
From the
Actions drop down list, select
Storage > New Datastore....
The
New Datastore wizard appears.
In the
New Datastore wizard, do the following:
Select VMFS as the datastore type.
Specify a datastore name and a disk/LUN for provisioning the datastore.
Specify the VMFS version for the datastore.
Review the disk layout and specify the partition configuration details.
Review the datastore information, and click
Finish.
Results
The Unity VMFS datastores are configured for the ESXi host.