Omitir para ir al contenido principal
  • Hacer pedidos rápida y fácilmente
  • Ver pedidos y realizar seguimiento al estado del envío
  • Cree y acceda a una lista de sus productos
  • Administre sus sitios, productos y contactos de nivel de producto de Dell EMC con Administración de la empresa.

Server Administrator Version 7.4 Messages Reference Guide

PDF

Event ID — 2310

Description
A virtual disk is permanently degraded.
Severity
Critical / Failure / Error
Cause and Action
Cause: A redundant virtual disk has lost redundancy. This may occur when the virtual disk suffers the failure of multiple physical disks. In this case, both the source physical disk and the target disk with redundant data have failed. A rebuild is not possible because there is no redundancy.

Action: Replace the failed disks and restore from backup.

Related Alert Information
Clear Alert Number: 1204

Related Alert Number: None

Local Response Agent (LRA) Number: 2081

SNMP Trap Numbers
1204