Prerequisites for M1000e (with MXL), Cisco Nexus, and Compellent

The following table describes the prerequisites for the FCoE solution offered using M1000e (with MXL), Cisco Nexus, and Compellent. For more information, see http://en.community.dell.com/techcenter/extras/m/white_papers/20387203

Resource Prerequisites
MXL
  • DCB needs to be enabled.

  • VLT needs to be disabled.

  • FIP Snooping feature needs to be enabled on the MXL.

    conf
                                                          Feature fip-snooping
                                                       
  • Port-channel member interfaces needs to have below configuration.

    interface range tengigabitethernet 0/33 – 36
                                                          port-channel-protocol lacp
                                                          port-channel 128 mode active
                                                          exit
                                                          
                                                          protocol lldp
                                                          no advertise dcbx-tlv ets-reco
                                                          dcbx port-role auto-upstream
                                                          no shut
                                                          exit
                                                       
  • Port-channel connecting Cisco Nexus switch needs to have following configuration.

    interface port-channel 128
                                                          portmode hybrid
                                                          switchport
                                                          fip-snooping port-mode fcf
                                                          
                                                       
  • Server facing ports needs to have following configuration.

    portmode hybrid
                                                          switchport
                                                          protocol lldp
                                                          dcbx port-role auto-downstream
                                                          no shut
                                                          exit
                                                       
Cisco Nexus

Following is the prerequisite for Cisco Nexus.

  • Enable required features.

    feature fcoe
                                                          feature npiv
                                                          feature lacp
                                                       
  • Create a new VSAN - instantiate it in the VSAN database.

    conf
                                                          vsan database
                                                          vsan <vsan id>
                                                       
  • Configure regular ethernet VLANs, and then the FCoE VLAN is created with an assignment to its respective VSAN.

    vlan <fcoe vlan>
                                                          fcoe vsan <vsan>
                                                       
  • Instantiate but do not configure the upstream port-channel (LAG) to the core /aggregation switch.

  • Instantiate but do not configure the downstream port-channel (LAG) to the IOA4.

  • Create the VFC interface to bind to the servers CNA FIP MAC address. This can be located in the CMC WWN table or the IDRAC page for the server.

    Example

    interface vfc101
                                                          bind mac-address 5C:F9:DD:16:EF:07
                                                          no shutdown
                                                          
                                                          interface vfc102
                                                          bind mac-address 5C:F9:DD:16:EF:21
                                                          no shutdown
                                                       
  • Move back into the VSAN database and create entries for the new VFC just created and create entries for the FC port(s) that will be used.

    vsan database

    vsan 2 interface vfc101

    vsan 2 interface vfc102

    vsan 2 interface fc2/1

    vsan 2 interface fc2/2

    • NOTE: All the Compellent ports needs to part of the same VSAN.
Compellent

Create fault domain as per Compellent best practices.


Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"