Omitir para ir al contenido principal
  • Hacer pedidos rápida y fácilmente
  • Ver pedidos y realizar seguimiento al estado del envío
  • Cree y acceda a una lista de sus productos
  • Administre sus sitios, productos y contactos de nivel de producto de Dell EMC con Administración de la empresa.

Active System Manager Release 8.1.1 Installation Guide

PDF

Prerequisites for Rack Server, Cisco Nexus, Brocade, and Dell Compellent

The following table describes the prerequisites for the FCoE solution offered using Rack Server, Cisco Nexus, Brocade, and Dell Compellent. For more information, see http://en.community.dell.com/techcenter/extras/m/white_papers/20387203

Resource Prerequisites
Cisco Nexus

Following is the prerequisite for Cisco Nexus:

  • Enable “npv” feature on the switch. You need to reboot the switch and delete the old configuration. (Ensure to back up the configuration before enabling the feature).

    conf
                                                          feature npv
                                                       
  • Enable required features.

    feature fcoe
                                                          feature npiv
                                                          feature lacp
                                                       
  • Create VSAN-instantiate it in the VSAN database.

    conf
                                                          vsan database
                                                          vsan <vsan id>
                                                       
  • Configure regular Ethernet VLANs, and then the FCoE VLAN is created with an assignment to its respective VSAN.

    vlan <fcoe vlan>
                                                          fcoe vsan <vsan>
                                                          
                                                       
  • Instantiate but do not configure the upstream port-channel (LAG) to the core /aggregation switch.

  • Instantiate but do not configure the downstream port-channel (LAG) to the IOA4.

  • Create the VFC interface to bind to the servers CNA FIP MAC address. This can be located in the CMC WWN table or the iDRAC page for the server.

    For Example:

    interface vfc101
                                                          bind mac-address 5C:F9:DD:16:EF:07
                                                          no shutdown
                                                          
                                                          interface vfc102
                                                          bind mac-address 5C:F9:DD:16:EF:21
                                                          no shutdown
                                                       
  • Move back into the VSAN database and create entries for the new VFC just created and create entries for the FC ports that are used.

    vsan database

    vsan 2 interface vfc101

    vsan 2 interface vfc102

    vsan 2 interface fc2/1

    vsan 2 interface fc2/2

    • NOTE: All the Dell Compellent ports need to part of the same VSAN.
Brocade

Alias needs to be created having Compellent fault domain WWPN, accessible on Brocade switch.

Dell Compellent

Create fault domain as per Dell Compellent best practices.


Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"