Dell PowerVault MD 32XX/36XX Series Storage Arrays CLI Guide

PDF

Creating SSD Cache

To create ssdCache command SSD read cache:
create ssdCache userLabel="
                                 ssdCacheName"
                                 physicalDisks=(
                                 enclosureID1,drawerID1,slotID1 ... enclosureIDn,drawerIDn,slotIDn)
                                 [updateExistingVirtualDisks=(TRUE|FALSE)]
                              

The ssdCacheName parameter names the cache group. Setting the updateExistingVirtualDisks parameter to TRUE enables SSD caching for all virtual disks in the storage array.

The following restrictions apply:
  • A storage array can have only one SSD cache.
  • Only virtual disks created using physical disks can use the SSD cache. You cannot enable SSD cache on snapshot (legacy) virtual disks or snapshot images.