Steps
Align the slots on the control panel board with the metal
standoffs on the control panel and slide the control panel board into
the control panel.
When firmly seated, the KVM connectors on the control
panel board align with the slots on the control panel.
Attach the two screws to secure the control panel board
to the control panel.
Reconnect the power cable to the control panel board.
Reconnect the LCD module cable to the control panel board.
Reinstall the LCD cable holder.
Reinstall the control panel.
Reconnect the control panel cable to its connector on the
system board.
Reinstall the cooling fan assembly.
Reinstall the cooling shroud.
Close the system.
If applicable, place the system upright on a flat, stable
surface and rotate the system feet outward.
Reinstall the hard drives.
Reinstall the server modules.
Reconnect the enclosure to its electrical outlet and turn the enclosure on, including any attached peripherals.
Turn on the server modules using the operating system commands
or the CMC.
If applicable, install the front bezel.