Ga naar hoofdinhoud
  • Snel en eenvoudig bestellen
  • Bestellingen en de verzendstatus bekijken
  • Een lijst met producten maken en openen
  • Beheer uw Dell EMC locaties, producten en contactpersonen op productniveau met Company Administration.

Dell Chassis Management Controller Version 1.3 for PowerEdge FX2/FX2s User's Guide

Configuring power budget and Redundancy using RACADM

  • NOTE: To perform power management actions, you must have the Chassis Configuration Administrator privilege.
To enable and set the redundancy policy:
  1. Open a serial/Telnet/SSH text console to CMC and log in.
  2. Set properties as needed:
    • To select a redundancy policy, type:
      racadm config -g cfgChassisPower -o
                                                cfgChassisRedundancyPolicy <value>
                                             

      where < value> is 0 (No Redundancy), 1 (Grid Redundancy), and 3 (Redundancy Alerting Only). The default value is 3.

      For example, the following command sets the redundancy policy to :

      racadm config -g cfgChassisPower -o
                                                cfgChassisRedundancyPolicy 1
                                             
    • To set the power budget value, type:
      racadm config -g cfgChassisPower -o
                                                cfgChassisPowerCap <
                                                value>
                                             
      where < value> is a number between the Current runtime Chassis Burden and 3371, representing the maximum power limit in Watt. The default is 3371.

      For example, the following command sets the maximum power budget to 3371 Watt:

      racadm config -g cfgChassisPower -o
                                                cfgChassisPowerCap 3371
                                             
    • To view the upper bound and the lower bound, type:
      racadm getconfig -g cfgchassispower -o cfgchassispowercap <
                                                   lower,upper> bound
                                                   
                                                
      where < lower, upper> is the lower bound and the upper bound limit.
      racadm config -g cfgChassisPower -o
                                                   cfgChassisPowerCap 3000
                                                
    • To enable the maximum power consumption mode, type:
      racadm config -g cfgChassisPower -o
                                                cfgChassisMaxPowerConservationMode 1
                                             
    • To restore normal operation, type:
      racadm config -g cfgChassisPower -o
                                                cfgChassisMaxPowerConservationMode 0
                                             
    • To enable the power remote logging feature, enter the following command:
      racadm config -g cfgRemoteHosts -o
                                                cfgRhostsSyslogPowerLoggingEnabled 1
                                             
    • To specify the desired logging interval, enter the following command:
      racadm config -g cfgRemoteHosts -o
                                                cfgRhostsSyslogPowerLoggingInterval 
                                                n
                                                
                                             
      where n is 1-1440 minutes.
    • To determine if the power remote logging feature is enabled, enter the following command:
      racadm getconfig -g cfgRemoteHosts -o
                                                cfgRhostsSyslogPowerLoggingEnabled
                                             
    • To determine the power remote logging interval, enter the following command:
      racadm getconfig -g cfgRemoteHosts -o
                                                cfgRhostsSyslogPowerLoggingInterval
                                             
      The power remote logging feature is dependent on previously configured remote syslog hosts having been . Logging to one or more remote syslog hosts must be enabled, otherwise power consumption is logged. This can be done either through the web GUI or the RACADM CLI. For more information, see the remote syslog configuration instructions.
    • To restore CMC power management, type:
      racadm config -g cfgChassisPower -o
                                                cfgChassisServerBasedPowerMgmtMode 0
                                             
    For information about RACADM commands for chassis power, see the config, getconfig, getpbinfo, and cfgChassisPower sections in the Dell Chassis Management Controller for PowerEdge FX2/FX2s RACADM Command Line Reference Guide .

Beoordeel deze inhoud

Nauwkeurig
Nuttig
Eenvoudig te begrijpen
Was dit artikel nuttig?
0/3000 characters
  Geef een beoordeling (1-5 sterren).
  Geef een beoordeling (1-5 sterren).
  Geef een beoordeling (1-5 sterren).
  Selecteer of het artikel nuttig is of niet.
  Opmerkingen mogen geen speciale tekens bevatten: <>() \