Skip to main content
VxRail E660F image

VxRail E660F

Connectivity:  Generate Access key
VxRail E660F

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 1382 shown
1382 out of 1382 shown

This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated:  August 10, 2026 ID: 000205512

This article introduces the VxRail VxVerify tool and how to successfully run VxVerify in a VxRail environment.
Updated:  July 31, 2026 ID: 000021527

Software-Defined Data Center (SDDC) Manager precheck failure Multi-Site Service fails due to pantheon service in a failed state. Service Availability: Check if the service is up and running using command "systemctl status pantheon." As root user, restart the service if required using command "systemctl restart pantheon" from SDDC Manager VM.
Updated:  August 13, 2026 ID: 000420702

Event code: VXR508STOR5 This event code indicates "Redundancy lost.<VD/Enclosure Name>"
Updated:  August 13, 2026 ID: 000011745

Event code: VXR508RDU0013 This event code indicates "Power supply redundancy is degraded."
Updated:  August 13, 2026 ID: 000011744

Event code: VXR508PSU0002 This event code indicates "A predictive failure detected on power supply <number>."
Updated:  August 13, 2026 ID: 000011743

Event code: VXR508SWC4004 This event code indicates "A firmware or software incompatibility detected between iDRAC in slot <number> and CMC."
Updated:  August 13, 2026 ID: 000011742

Event code: VXR508VLT0302 This event code indicates "CPU <number> <name> voltage is greater than the upper warning threshold."
Updated:  August 13, 2026 ID: 000011716

Event code: VXR508VLT0230 This event code indicates "The mezzanine card <number> <name> voltage is less than the lower warning threshold."
Updated:  August 13, 2026 ID: 000011715

Event code: VXR508TMPS0100 This event code indicates "Inlet temperature is above warning level for extended duration."
Updated:  August 13, 2026 ID: 000011712

Event code: VXR508VDR54 This event code indicates "<VD Name> initialization is terminated."
Updated:  August 13, 2026 ID: 000011711

Event code: VXR508PDR211 This event code indicates "<physical disk name> has encountered storage medium error."
Updated:  August 13, 2026 ID: 000011710

Event code: VXR508MEM6003 This event code indicates "Memory device status is non-critical. Memory device location: <location>, Possible memory module event cause: <cause>."
Updated:  August 13, 2026 ID: 000011709

Event code: VXR508VLT0208 This event code indicates "The memory module <number> <name> voltage is greater than the upper warning threshold."
Updated:  August 13, 2026 ID: 000011707

Event code: VXR508VLT0206 This event code indicates "The memory module <number> <name> voltage is less than the lower warning threshold."
Updated:  August 13, 2026 ID: 000011706

Event code: VXR508VDR8 This event code indicates "<virtual disk> is degraded either because the physical disk drive in the drive group is removed or the physical disk drive added in a redundant virtual drive has failed."
Updated:  August 10, 2026 ID: 000011696

Event code: VXR508FAN0025 This event code indicates "The <sensor name> sensor state has changed to a warning state with a value of <fan speed> RPM."
Updated:  August 10, 2026 ID: 000011695

Event code: VXR508TMPS0101 This event code indicates "Inlet temperature is above critical level for extended duration."
Updated:  August 10, 2026 ID: 000011693

Event code: VXR508VDR100 This event code indicates "<virtual disk> is unavailable because of incompatibilities with the current controller."
Updated:  August 10, 2026 ID: 000011692

Event code: VXR508VLT0232 This event code indicates "The mezzanine card <number> <name> voltage is greater than the upper warning threshold."
Updated:  August 10, 2026 ID: 000011690

Event code: VXR508RFL2002 This event code indicates "Internal Dual SD Module <name> is offline."
Updated:  August 10, 2026 ID: 000011689

Event code: VXR508VLT0214 This event code indicates "The disk drive bay <name> voltage is greater than the upper warning threshold."
Updated:  August 10, 2026 ID: 000011687

Event code: VXR508VLT0220 This event code indicates "The <name> voltage is greater than the upper warning threshold."
Updated:  August 10, 2026 ID: 000011686

License fails to apply due to insufficient capacity.
Updated:  August 10, 2026 ID: 000054981

Explore the Dell End of Service Life (EOSL) and End of Life (EOL) list for converged infrastructure, storage, and storage networking products. Access End-of-Life documents for hardware, software, and firmware release and service dates
Updated:  August 10, 2026 ID: 000185734

Dell Samsung Serial Attached SCSI (SAS) PM1653 and PM1655 solid state drives may report excessive Sense Key faults 0x3, 0x11, 0x0, or 0x4, 0x29, 0x4. These faults have the potential to cause unexpected drive issues.
Updated:  August 10, 2026 ID: 000222201

This document describes how to validate, install, and manage custom third-party components in VxRail environments using VxRail vLCM. It outlines supported upgrade scenarios, common misconfigurations, and best-practice workflows to ensure reliable VxRail life cycle operations.
Updated:  August 10, 2026 ID: 000419960

Event code: VXR508VDR53 This event code indicates "The consistency check logging of inconsistent parity data is disabled for <virtual disk>."
Updated:  August 07, 2026 ID: 000011684

Event code: VXR508PSU0914 This event code indicates "A predictive failure detected on power unit <number>."
Updated:  August 07, 2026 ID: 000011683

Event code: VXR508VDR99 This event code indicates "<virtual disk> is unavailable because of an ID conflict in the fault-tolerant pair."
Updated:  August 07, 2026 ID: 000011682