Skip to main content

VxRail Software

VxRail Software

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 1633 shown
1633 out of 1633 shown

This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated:  July 13, 2026 ID: 000205512

A guide to Dell customers on how to prepare for an upgrade of their VxRail cluster with the Remote Proactive Support Team.
Updated:  July 08, 2026 ID: 000200768

VxRail upgrade on some releases encounters error code 1. Logs show a PBM error adding a disk, and the vSphere Storage Service reports ‘Healthy with errors’, blocking profile access.
Updated:  July 14, 2026 ID: 000218572

When the BIOS is updated with TXT enabled, it installs it encrypted as a security measure. If TXT is ever later disabled, a BIOS update is not allowed until TXT is reenabled.
Updated:  July 14, 2026 ID: 000217776

Power supply was removed from a node and expected a dial-home case to be created.
Updated:  July 14, 2026 ID: 000216706

During boot the VM shows “An unrecoverable IOException occurred so the connection was closed” then stops, logging a PIIX4 PM Soft Off entry, indicating the guest OS triggered the power‑off.
Updated:  July 14, 2026 ID: 000212683

After cancelling a VxRail Manager upgrade, VxVerify flags a lcm_state failure with a 404 API error, empty bundle_state.json, no LCM task in the database and missing lock data, showing LCM webapp stopped.
Updated:  July 14, 2026 ID: 000213078

Migration stops with an Open Virtual Appliance (OVA) pre‑migration health‑check timeout, shown as an SSH failure to an IPv6 address. The source VxRM VM has IPv6 disabled, causing the check to fail.
Updated:  July 14, 2026 ID: 000213933

During an upgrade to 8.0.380, the upgrade may fail during Platform Service queries after its reboot and upgrade of the Platform Service VIB to 8.0.380.29572188. In 8.0.380 the iSM VIB is removed, with the Platform Service taking over the tasks that iSM previously handled. Please DO NOT install the iSM VIB on hosts after they upgraded to 8.0.380.
Updated:  July 14, 2026 ID: 000459409

This KB article briefly discusses Event code: VXR508PDR56
Updated:  July 14, 2026 ID: 000011737

This KB article discusses using the Linux Domain Information Groper (dig) to verify the customer Domain Name System (DNS) configuration when there are suspected name resolution issues.
Updated:  July 14, 2026 ID: 000009594

Event code: VXR508PDR86 This event code indicates "Bad block table on <physical disk> is full."
Updated:  July 13, 2026 ID: 000011738

Event code: VXR508PSU0032 This event code indicates "The temperature for power supply <number> is in a warning range."
Updated:  July 13, 2026 ID: 000011736

Event code: VXR508STOR1 This event code indicates "A device <device name> is in an unknown state."
Updated:  July 13, 2026 ID: 000011735

Event code: VXR508TMP0132 This event code indicates "The control panel temperature is greater than the upper warning threshold."
Updated:  July 13, 2026 ID: 000011734

Event code: VXR508TMP0200 This event code indicates "CPU <number> temperature is less than the lower warning threshold."
Updated:  July 13, 2026 ID: 000011733

Event code: VXR508RDU0018 This event code indicates "The storage power redundancy is degraded."
Updated:  July 13, 2026 ID: 000011732

VxRail Cluster is running out of capacity space on VSAN and has RecoverPoint for Virtual Machines.
Updated:  July 13, 2026 ID: 000200261

Event code: VXR508PDR1004 This event code indicates "Consistency check is in progress for drive <number> in disk drive bay <bay>."
Updated:  July 10, 2026 ID: 000011524

Event code: VXR508NIC024 This event code indicates "The set operation did not complete successfully as the attribute is read-only."
Updated:  July 10, 2026 ID: 000011523

Event code: VXR508PSU100 This event code indicates "Power supply <power supply unit> is offline."
Updated:  July 10, 2026 ID: 000011522

Event code: VXR508PDR1008 This event code indicates "Rebuild was aborted for drive <number> in disk drive bay <bay>."
Updated:  July 10, 2026 ID: 000011521

Event code: VXR508PSU8503 This event code indicates "The PSU in slot <slot number> detected 220 VAC input voltage and does not match chassis configuration."
Updated:  July 10, 2026 ID: 000011517

Event code: VXR508PWR201 This event code indicates "Selecting the Server Based Power Management Mode option sets your power cap to a maximum value, server priorities to a default priority, and then disables the Max Power Conservation Mode. Do you want to continue?"
Updated:  July 10, 2026 ID: 000011513

Event code: VXR508PWR2261 This event code indicates "Current Monitor initialization issue observed, IMON Revision <current monitor revision number>, CPLD IMON MFR Revision <CPLD revision number>."
Updated:  July 10, 2026 ID: 000011511

Event code: VXR508PWR213 This event code indicates "Cannot enable the Extended Power Performance (EPP) mode because the Max Power Conservation Mode (MPCM) is enabled."
Updated:  July 10, 2026 ID: 000011510

Event code: VXR508PWR2251 This event code indicates "Unable to turn on the server because the chassis cover is open."
Updated:  July 10, 2026 ID: 000011509

Event code: VXR508PSU8519 This event code indicates "Enhanced Dynamic Power Supply Engagement (DPSE) is not supported by the current power supply configuration and is suspended."
Updated:  July 10, 2026 ID: 000011508

Event code: VXR508PWR209 This event code indicates "Unable to change the redundancy policy to either Power Supply Redundancy or No Redundancy because the Extended Power Performance is enabled."
Updated:  July 10, 2026 ID: 000011506

Event code: VXR508PWR2400 This event code indicates "Power management firmware unable to maintain power limit."
Updated:  July 10, 2026 ID: 000011505