Skip to main content
PowerEdge R7715 image

PowerEdge R7715

PowerEdge R7715

Articles

Select a category and then a related component to find articles about specific hardware and software.

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 419 shown
419 out of 419 shown

Unsure about the procedure to update a specific component's firmware in a PowerEdge system? Learn how to in this specific article.
Updated:  May 23, 2026 ID: 000333712

This article details the most recent firmware version for Integrated Dell Remote Access Controller 10 (iDRAC10), designed for Dell PowerEdge servers from the 17th generation onwards.
Updated:  May 22, 2026 ID: 000305325

This article provides information about Intermittent High Fan Speeds on Dell 17G PowerEdge Servers with NVIDIA ConnectX-6 OCP Cards installed.
Updated:  May 23, 2026 ID: 000334522

This KB is to provide information about Dell customized VMware ESXi support stance on the Dell 17th generation of PowerEdge servers. The 17th generation of PowerEdge servers is based on Intel® Xeon® 6500P/6700P (Granite Rapids SP) and AMD EPYC™ 9005 Series Processor (Turin).
Updated:  May 23, 2026 ID: 000334057

Dell PowerEdge 17th Generation Servers: A rare issue exists with Delta power supplies (PSU) that causes a PSU mismatch.
Updated:  May 23, 2026 ID: 000328861

New deployments of OpenManage Enterprise 4.4.0 are experiencing service failures after configuring the time zone for GMT +02:00 Helsinki, Kyiv, Riga, Sofia, Tallinn, Vilnius. The issue is only seen on fresh deployment of OpenManage Enterprise (OME) 4.4.0 on Hyper-V. Deploying OpenManage Enterprise (OME) on other hypervisors is not impacted.
Updated:  May 23, 2026 ID: 000326459

R7725, R6725, R7715, and R6715 the number of CPU Cores is not recognized correctly.
Updated:  May 23, 2026 ID: 000321587

Dell PowerEdge 17G servers that shipped before March 24, 2025 will prompt for Liquid Cooling capability after updating iDRAC10 firmware.
Updated:  May 23, 2026 ID: 000319232

Dell Enterprise NVMe solid state drives may be leveraged as a substitute for Dell Data Center NVMe solid state drives.
Updated:  May 23, 2026 ID: 000315161

PowerEdge: Dell service support for end of industry production of 2.5" 15k RPM SAS hard drives
Updated:  May 23, 2026 ID: 000314166

Dell Technologies advises against downgrading Hard Drive or SSD firmware, except in validated scenarios, due to unpredictable results and version reporting issues.
Updated:  May 23, 2026 ID: 000311902

Dell Micron 9550 E3.S NVMe Drive Activity-Led light turns off for a few seconds.
Updated:  May 23, 2026 ID: 000309831

Users attempting to exit Enhanced Pre-Boot System Assessment (ePSA) diagnostics may encounter a system stop upon selecting the Exit option.
Updated:  May 22, 2026 ID: 000291042

Leveraging the 'Reboot Required' filter and selecting all items in this filtered view results in the 'make compliant' job applying all non-compliant firmware components. An unexpected reboot of the target is seen as components that do require a restart are deployed to the target. The issue is only seen if selecting all objects and using the 'Reboot Required' filter. All other filters work as designed.
Updated:  May 22, 2026 ID: 000270340

PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
Updated:  May 22, 2026 ID: 000256907

CPUs can be perceived to be hot while server is idle.
Updated:  May 22, 2026 ID: 000250878

NVIDIA L-series GPUs may fall offline during runtime operations when running vGPU Grid 17.2 drivers.
Updated:  May 22, 2026 ID: 000250524

Performance drops after power supply unit (PSU) cable removal and does not recover upon reconnection, despite the A/B Grid Redundant policy being active in iDRAC10.
Updated:  May 22, 2026 ID: 000247062

Racadm diagnostics "-m 2" switch returns express diagnostics results only.
Updated:  May 22, 2026 ID: 000246053

Dust or chemical contamination at the endface of a fiber optic LC connector or transceiver module impedes signaling. Dell engineering teams have verified cases in which a fully functional port appears to be a bad port because dirty optical connectors manifest as a port failing loop testing with acceptable power measurement levels. Cable connectors should be cleaned and when stored must be protected from dust particle or chemical contamination.
Updated:  May 22, 2026 ID: 000246018

Inband updates to Open Server Manager (OSM) with .bin DUP results in a watchdog soft lockup error. Update is successful.
Updated:  May 22, 2026 ID: 000244474

Dell Update Package (DUP) can randomly fail in Red Hat Enterprise Linux (RHEL) or Ubuntu.
Updated:  May 22, 2026 ID: 000242250

The Lifecycle Controller logs reports SPDM0001 and SPDM0003 warning messages after every iDRAC reset.
Updated:  May 21, 2026 ID: 000242100

Observing system stop responding or Purple Screen Of Death (PSOD) during ESXi 8.0 U3 installation,
Updated:  May 21, 2026 ID: 000241608

Seagate Summit SAS/SATA drives report medium errors or sense key 3/11 on PowerEdge and PowerVault systems due to a firmware issue causing weak writes to a drive sector.
Updated:  May 21, 2026 ID: 000239838

The BIOS setting changes may not appear in iDRAC if configured using the F11 Boot Manager on Dell PowerEdge 16G and 17G platforms.
Updated:  May 21, 2026 ID: 000238951

In Windows Server 2025, when leveraging CPUs with more than 256 cores, the Broadcom BCM5720 fails to retrieve a DHCP address, leading to no network connectivity.
Updated:  May 21, 2026 ID: 000233949

OpenManage Enterprise integration for VMware vCenter may fail to Unmanage hosts with error "UNMANAGE_REMOVE_MEL_FAILURE"
Updated:  May 21, 2026 ID: 000233873

When a PS1010 or PS1030 NVMe SSD is installed, a PSOD may occur during production or gathering Operating System (OS) logs.
Updated:  May 21, 2026 ID: 000228837

OpenManage Enterprise version 4.1 entitlements feature will no longer work after October 2024 due to the decommissioning of legacy OAUTH APIs. Also, the standalone Dell License Manager application is end-of-life.
Updated:  May 21, 2026 ID: 000228401