Skip to main content

PowerFlex Software

Connectivity:  Generate Access key
PowerFlex Software

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 1038 shown
1038 out of 1038 shown

This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Datacenter Infrastructure products. We carefully evaluate and monitor code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated:  February 09, 2026 ID: 000205512

This article details the procedure to troubleshoot power supply unit (PSU) issues that may arise on a PowerEdge Server.
Updated:  February 07, 2026 ID: 000127944

Since the introduction of Clustered VMDK on VMFS datastores, applications like Windows Server Failover Cluster (WSFC) no longer require Raw Device Mappings (RDMs) to use SCSI‑3 persistent reservations (SCSI3‑PR). Because of this, Broadcom does not offer RDM support for the NVMeoF protocol. Customers using RDMs with the SDC who want to move to NVMe/TCP must convert those disks to VMDKs on a VMFS datastore with the Clustered VMDK property. This conversion cannot be done with Storage vMotion, so applications such as WSFC will incur downtime. This KB explains how to perform the WSFC conversion at a high-level. It also covers converting an Oracle RAC environment from RDMs to shared VMDKs on NVMe/TCP, even though Oracle RAC does not require SCSI3‑PR. Oracle RAC can run on an SDC‑based VMFS datastore, but because PowerFlex does not support Clustered VMDK on SDC‑based VMFS, SCSI3‑PR‑dependent applications cannot use that configuration. Oracle RAC explanations are also high-level.
Updated:  February 10, 2026 ID: 000417124

PowerFlex allows authentication and authorization to be enabled for all SDCs connected to a cluster. Once authentication and authorization are enabled, older SDC clients and SDCs without a configured password are disconnected.
Updated:  February 09, 2026 ID: 000332124

Explore the Dell End of Service Life (EOSL) and End of Life (EOL) list for converged infrastructure, storage, and storage networking products. Access End-of-Life documents for hardware, software, and firmware release and service dates
Updated:  February 09, 2026 ID: 000185734

Running command svm status connection is showing both CloudLink nodes as Inaccessible due to blocked port UDP 1194.
Updated:  February 09, 2026 ID: 000384973

In the PFxM UI, there is an alert stating that events from the MDM are not being retrieved.
Updated:  February 09, 2026 ID: 000221796

Upgrading to PowerFlex Management Platform (PFMP) 4.8 may cause the UI to load with the error "Failed to initialize" or be accessible but unstable.
Updated:  February 09, 2026 ID: 000417603

PowerFlex Manager cannot interact with the PowerFlex system when a login banner is configured, disrupting automation tasks.
Updated:  February 07, 2026 ID: 000253256

This article provides a resolution when remote access for the ESXi local user account root is locked for 900 s after failed login attempts. Connect to the iDRAC console to access the ESXi shell then run the reset command.
Updated:  February 05, 2026 ID: 000071365

When performing many tasks related to CloudLink Agent on Linux machines, you use the SVM command. This command has several subcommands that are used to perform actions including registering, encrypting, reloading machines, and removing mount points.
Updated:  February 05, 2026 ID: 000421572

The upgrade fails when SupportAssist is configured before running the upgrade for version 4.6.2.
Updated:  February 04, 2026 ID: 000311707

Unable to unmap volumes from the SDC. "Error: MDM failed command. Status: The volume class provided does not match the expected volume class"
Updated:  February 04, 2026 ID: 000421825

This article explains how to split a large Resource Group (RG) into smaller RGs while using the same Protection Domain (PD) in PowerFlex Management Platform (PFMP) or to split a large Service into smaller Services in PowerFlex Manager (PFxM).
Updated:  February 04, 2026 ID: 000388444

For security reasons it might be necessary to change the password for the root user on a VMware ESXi host after installation. This article provides guidance to change the root password for the VMware ESXi host using VMware vSphere Client, VMware ESXi shell command, and VMware ESXi host System Customization menu.
Updated:  February 04, 2026 ID: 000324321

PowerFlex/PowerEdge: How to Sanitize NVDIMM - Video
Updated:  February 03, 2026 ID: 000221219

this article explains a rare occurrence if a bug were After Upgrade OS packages on MVMs still show old version and how to fix it
Updated:  February 03, 2026 ID: 000423205

This article provides links to PowerFlex software technical documentation.
Updated:  February 03, 2026 ID: 000314729

When PowerPath for Windows version 6.1 is installed on Windows Server 2016, validation alerts indicate that many drivers have dates earlier than the OS, because the PowerPath release predates the OS.
Updated:  February 03, 2026 ID: 000062991

This article explains how to Standardizing Data VLAN Tagging After PFxM Upgrade and OS Conversion.
Updated:  February 03, 2026 ID: 000406776

This article explains how to troubleshoot Resource Group (RG) in life cycle (LC) Mode because vCLS are not on shared storage.
Updated:  February 02, 2026 ID: 000325157

This article explains how to troubleshoot the PowerFlex create template error because of template already exists.
Updated:  February 02, 2026 ID: 000325160

This article explains how to troubleshoot being unable to upgrade Storage Only (SO) Resource Group (RG) after upgrading the PowerFlex Manager. This issue is because CloudLink must be upgraded before the Storage Only Node.
Updated:  February 02, 2026 ID: 000325262

This article explains how to troubleshoot being unable to add the management Resource Group (RG) as an existing RG due to PFMC gateway MDS pod failing to receive traffic from the MDM Cluster.
Updated:  February 02, 2026 ID: 000325280

Adding an existing Resource Group (RG) in PowerFlex Manager fails and reports that the RG is in a critical state.
Updated:  February 02, 2026 ID: 000325442

During deploying Storage Only (SO) Resource Group (RG), some SDSs fail due to MTU mismatch between SDS interface and switches
Updated:  February 02, 2026 ID: 000325650

This article explains how to understand the purple screen (PS) root cause.
Updated:  February 02, 2026 ID: 000327283

This guide explains the deployment types available, depending on your deployment requirements, go to one of the following parts:
Updated:  February 02, 2026 ID: 000417854

When deploying a Storage-Only Resource Group on PowerFlex 5.x, the deployment wizard fails at IP reservation with error IDENTITYPOOLMANAGER.3004. The root cause is IP pools sized only for the storage nodes, without accounting for the additional MDM virtual IPs required by the deployment.
Updated:  January 30, 2026 ID: 000412601

Use this procedure to upgrade both the PowerFlex software and the PowerFlex nodes. Perform the storage software update first.
Updated:  January 30, 2026 ID: 000323127