This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Datacenter Infrastructure products. We carefully evaluate and monitor code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated: May 18, 2026
ID: 000205512
Step-by-step guidance to replace with customer certificates for Dell VxRail environments. vSphere provides security by using certificates to encrypt communications, authenticate services, and sign tokens. (Customer Correctable)
Updated: May 15, 2026
ID: 000019755
This article explains where to find firmware files on the VxRail Manager for use after a node re-imaging operation or a component replacement on a node.
The firmware in the recovery bundle contains the correct versions for the running cluster code.
Updated: May 23, 2026
ID: 000331213
Dell VxRail Security Technical Implementation Guide (STIG) for VMware Cloud Foundation on VxRail v1.1.001.
Updated: May 23, 2026
ID: 000321689
vCLS Virtual machines (VM) will not deploy in a cluster, even after enabling and disabling retreat mode.
Updated: May 23, 2026
ID: 000318887
VxVerify upgrade precheck fails with "Failure to access all the necessary Python packages" and ModuleNotFoundError.
Updated: May 23, 2026
ID: 000312471
Event code VXR034011 is present on VxRail Manager.
Updated: May 22, 2026
ID: 000070696
The intent of this KB is to provide the proper course of action to take in the event that the notified mystic code takes place.
Updated: May 22, 2026
ID: 000165355
Event VXR108100 is reported when the VxRail cluster is still at a version lower than 8.0.330.
Updated: May 22, 2026
ID: 000328255
Event VXR0140A4 is reported when the Core and Inventory disk reaches 90% capacity.
Updated: May 22, 2026
ID: 000214541
Event VXR0140A3 is reported when the SEAT disk reaches 90% capacity.
Updated: May 22, 2026
ID: 000214540
Event VXR0140A2 is reported when the Log disk reaches 90% capacity.
Updated: May 22, 2026
ID: 000214539
Event VXR500UEFI0440 is reported when the client cannot access iDRAC due to reaching the maximum number of login attempts.
Updated: May 22, 2026
ID: 000213132
Event VXR500SUP0556 is reported when some of the components fail to start or complete the firmware update operation.
Updated: May 22, 2026
ID: 000213131
Support iDRAC events monitor: STOR704
Updated: May 22, 2026
ID: 000207000
Support iDRAC events monitor: SEKM098
Updated: May 22, 2026
ID: 000206999
Support iDRAC events monitor: CPU7114
Updated: May 22, 2026
ID: 000206992
Event code: VXR500AMP0319
This event code indicates "Chassis power level current is less than the lower critical threshold."
Updated: May 22, 2026
ID: 000189610
Event VXR508CTL139 indicates: The storage controller arg1 is unable to communicate to the BMC because of arg2 Error. iDRAC management for this device is unavailable.
Updated: May 22, 2026
ID: 000189227
Event VXR508TMP0153 indicates: Communication with one or more temperature sensors is not available and fan speeds may have increased to protect the system.
Updated: May 22, 2026
ID: 000189226
Event VXR500PSU8531 indicates: The Power Supply Unit <slotnum> reported input overcurrent fault and has been turned off.
Updated: May 22, 2026
ID: 000189225
Event VXR500PSU8530 indicates: The Power Supply Unit <slotnum> reported an input undervoltage fault and has been turned off.
Updated: May 22, 2026
ID: 000189224
Event VXR500PSU8529 indicates: The temperature of Power Supply Unit <slotnum> exceeded upper temperature threshold and has been turned off.
Updated: May 22, 2026
ID: 000189223
This health-check analyzes the /etc/hosts file for known issues which can cause upgrades to fail and can correct these if necessary.
Updated: May 22, 2026
ID: 000217240
vSAN plug-in missing in vSphere web client
Updated: May 22, 2026
ID: 000219820
This article explains a compatibility issue between the VxRail Node Image Management (NIM) tool and specific Windows versions.
Updated: May 22, 2026
ID: 000261072
This article explains how VxRail Manager File-based backups scheduled in a VxRail release prior to 7.0.520 or 8.0.300 can stop working after a code upgrade.
Updated: May 22, 2026
ID: 000260789
This article explains how enabling vSphere Lifecycle Manager (vLCM) for VxRail returns an unexpected internal error. This scenario happens when TCP port 5480 is closed between VxRail Manager and customer vCenter.
Updated: May 22, 2026
ID: 000258975
The Microsoft SQL Trace Flag 1800 is a setting that enables SQL Server 4k I/O alignment for the SQL transaction log volume.
In this article, we explore the cause of transaction log misaligned I/O and the benefits of using the trace flag 1800. This applies to Dell and other vendor storage solutions with virtualized SQL solutions.
Updated: May 22, 2026
ID: 000248395
Event VXR508PSU0917 indicates: The server is unable to communicate with Power Supply <number>.
Updated: May 21, 2026
ID: 000189222