All products: Contaminants such as dust on fiber optic connector end face causes poor IO performance
Dust or chemical contamination at the endface of a fiber optic LC connector or transceiver module impedes signaling. Dell engineering teams have verified cases in which a fully functional port appears to be a bad port because dirty optical connectors manifest as a port failing loop testing with acceptable power measurement levels. Cable connectors should be cleaned and when stored must be protected from dust particle or chemical contamination.
Updated: May 22, 2026
ID: 000246018
This article provides a step-by-step guide on how to remove and install a cooling fan on a Dell system. These instructions are applicable to both standard and high-performance fans. The guide covers the removal and installation of the cooling fan assembly.
Updated: May 21, 2026
ID: 000234366
PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
Updated: May 22, 2026
ID: 000256907
CPUs can be perceived to be hot while server is idle.
Updated: May 22, 2026
ID: 000250878
Beginning with 15G PowerEdge, servers are offered in configurations that report more drive connections than are physically available.
Updated: May 22, 2026
ID: 000250643
PowerEdge T160, R260, T360, R360: Ubuntu 22.04.1 and 22.04.2 are not validated and may cause an out-of-memory error.
Updated: May 22, 2026
ID: 000245172
Seagate Summit SAS/SATA drives report medium errors or sense key 3/11 on PowerEdge and PowerVault systems due to a firmware issue causing weak writes to a drive sector.
Updated: May 21, 2026
ID: 000239838
The BIOS setting changes may not appear in iDRAC if configured using the F11 Boot Manager on Dell PowerEdge 16G and 17G platforms.
Updated: May 21, 2026
ID: 000238951
The Dell SS540 SAS solid state drive is reported as not correctly functioning.
Updated: May 21, 2026
ID: 000237298
PowerEdge: Broadcom NXE devices with Driver 229.2.73 (SWB: Y7T4X) may report that the interfaces are missing in the operating system when secure boot is enabled.
Updated: May 21, 2026
ID: 000236776
In some instances, the firmware update job may fail to initiate when performing a firmware update through available iDRAC interfaces.
Updated: May 21, 2026
ID: 000234480
In Windows Server 2025, when leveraging CPUs with more than 256 cores, the Broadcom BCM5720 fails to retrieve a DHCP address, leading to no network connectivity.
Updated: May 21, 2026
ID: 000233949
OpenManage Enterprise integration for VMware vCenter may fail to Unmanage hosts with error "UNMANAGE_REMOVE_MEL_FAILURE"
Updated: May 21, 2026
ID: 000233873
When a PS1010 or PS1030 NVMe SSD is installed, a PSOD may occur during production or gathering Operating System (OS) logs.
Updated: May 21, 2026
ID: 000228837
This article describes the different type of controllers and the ways in which they should be reseated.
Updated: May 21, 2026
ID: 000228521
Warning messages regarding "icen_SetRxQueueFilter" and "Failed to add cloud filter" in ESXi 8 VMware VMkernel log.
Updated: May 21, 2026
ID: 000228397
An "HWC1110" event was reported during the iDRAC Firmware update.
Updated: May 21, 2026
ID: 000228298
The front hard drive slots 4 and 5 have a nonfunctional HDD4/HDD5 slot label with a 4x2.5 ChipSATA configuration.
Updated: May 21, 2026
ID: 000228297
The article describes how to troubleshoot network connectivity issues for network cards.
Updated: May 21, 2026
ID: 000227983
Seagate Skybolt and SkyboltServoBP drive fails with medium format corrupted errors.
Updated: May 21, 2026
ID: 000227930
This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server.
It is also relevant for 100% fan speeds.
Updated: May 21, 2026
ID: 000227912
Dell has introduced significant updates to how PowerEdge servers manage coin-cell (CMOS) battery functionality and related event logging. Beginning with 14th Generation (14G) servers in August 2024 — through iDRAC and BIOS firmware updates — and extending to 15G and 16G platforms from February 2025 onward, several key changes have been implemented
Updated: May 21, 2026
ID: 000227413
This article provides information about Fatal BUS errors seen with PCI1360 and PCI1318.
Updated: May 21, 2026
ID: 000227163
How to create Cluster Shared Volumes by manually calculating the necessary disk space value.
Updated: May 21, 2026
ID: 000227068
Dell Intel SATA SSD drives may report a not correctly functioning PDR3 event, potentially resulting in a drive failure condition.
Updated: May 21, 2026
ID: 000226989
PowerEdge T360, R360, R260, T160: CPU turbo boost cannot reach the theoretical max frequency.
Updated: May 21, 2026
ID: 000226634
This article describes how to view and clear the system event log (SEL) in System Setup.
Updated: May 21, 2026
ID: 000226396
This article describes how to find the iDRAC's current MAC address.
Updated: May 21, 2026
ID: 000226214
Updating 16G PowerEdge Server BIOS may result in Secure Boot database updates.
Updated: May 21, 2026
ID: 000226055
The PowerEdge 16G 700 W Power supply, Dell Part Number (DPN): 3D09N, only supports high line voltage, the input voltage range is 200 V AC-240 V AC.
Updated: May 21, 2026
ID: 000225989