Skip to main content

VxRail E660N

Connectivity:  Generate Access key
VxRail E660N

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 1509 shown
1509 out of 1509 shown

This article introduces the VxRail VxVerify tool and how to successfully run VxVerify in a VxRail environment.
Updated:  September 18, 2026 ID: 000021527

This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated:  September 15, 2026 ID: 000205512

This article provides guidance for assessing, planning, and installing ESXi Express Patches in VxRail environments. It outlines key considerations, recommended procedures, and operational best practices to help ensure a successful and supported patch deployment.
Updated:  September 19, 2026 ID: 000509330

VXR0140A1 alarm triggers when vSAN (vSAN) cluster storage space exceeds configured thresholds (vSAN 7.0 Update 2 onward). Check and reduce vSAN datastore usage per VMware KB 71003.
Updated:  September 18, 2026 ID: 000182229

This Knowledge Base article explains the steps to take when the VxRail (Virtual Extensible Infrastructure) alarm VXR01406E / MYSTIC01406E – Virtual SAN (Storage Area Network) Health Alarm ‘Advanced Virtual SAN configuration in sync’ is triggered.
Updated:  September 18, 2026 ID: 000038717

User Guide for VxRail Troubleshooting Toolbox (VTT)
Updated:  September 17, 2026 ID: 000214621

Explore the Dell End of Service Life (EOSL) and End of Life (EOL) list for converged infrastructure, storage, and storage networking products. Access End-of-Life documents for hardware, software, and firmware release and service dates
Updated:  September 16, 2026 ID: 000185734

While performing the "RCM" upgrade, it is recommended to set the I/O priority for Rebuild, Rebalance, and Maintenance Mode Policy to unlimited.
Updated:  September 16, 2026 ID: 000226257

PowerFlex Rebuild, Rebalance, and Maintenance policies that should be set before and after RCM upgrades.
Updated:  September 16, 2026 ID: 000186547

VxRail upgrade fails during the VxRail Manager post-upgrade stage with "Failed to reconfig the backup schedule" when an empty vxmbackup.json exists on VxRail Manager.
Updated:  September 16, 2026 ID: 000476283

This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated:  September 15, 2026 ID: 000502480

Dell VxRail Security Technical Implementation Guide (STIG) on VxRail.
Updated:  September 15, 2026 ID: 000023137

After upgrade to 8.0.x, vCenter cannot add the node by its Fully Qualified Domain Name (FQDN), handshake errors; IP works, and a firewall blocking SSL traffic between vCenter and ESXi host is cause.
Updated:  September 14, 2026 ID: 000227682

Event code: VXR508BAT0010 This event code indicates "The storage battery for disk drive bay <bay> is low."
Updated:  September 14, 2026 ID: 000011862

This article explains how to query and update the saved VxRail credentials in VxRail Manager in versions 7.0.x and 8.0.x.
Updated:  September 14, 2026 ID: 000157662

Event code: VXR508CTL72 This event code indicates "The foreign configuration overflow has occurred on <Controller name>."
Updated:  September 10, 2026 ID: 000011861

Event code: VXR508CPU0012 This event code indicates "Correctable Machine Check Exception detected on CPU <number>."
Updated:  September 10, 2026 ID: 000011860

Event code: VXR508CTL41 This event code indicates "Single-bit ECC error on <Controller name>."
Updated:  September 10, 2026 ID: 000011859

Event code: VXR508CTL61 This event code indicates "Physical disks found missing from configuration during boot time on <Controller name>."
Updated:  September 10, 2026 ID: 000011858

Event code: VXR508CTL74 This event code indicates "Preserved cache detected on <controller name>."
Updated:  September 10, 2026 ID: 000011857

Event code: VXR508CTL55 This event code indicates "<Controller name> event log: <args>"
Updated:  September 10, 2026 ID: 000011856

Event code: VXR508CTL79 This event code indicates "Controller in <controller slot> is not supported and will not be powered on."
Updated:  September 10, 2026 ID: 000011855

Event code: VXR508BAT1004 This event code indicates "The battery on <controller name> learn cycle has timed out."
Updated:  September 10, 2026 ID: 000011854

Event code: VXR508BAT1008 This event code indicates "Write policy on <controller name> was changed to Write Through."
Updated:  September 10, 2026 ID: 000011853

Event code: VXR508CTL63 This event code indicates "Previous configuration was found completely missing during boot time on <Controller name>."
Updated:  September 10, 2026 ID: 000011852

Event code: VXR508BAT1031 This event code indicates "The battery temperature on <controller name> is above normal."
Updated:  September 10, 2026 ID: 000011851

Event code: VXR508CTL92 This event code indicates "<controller name> is not operating in Fault Tolerant Mode because of an incompatible license setting on its peer controller."
Updated:  September 10, 2026 ID: 000011850

Event code: VXR508BAT1010 This event code indicates "Battery on <Controller name> requires reconditioning. Initiate a learn cycle."
Updated:  September 10, 2026 ID: 000011849

Event code: VXR508CPU0010 This event code indicates "CPU <number> is throttled."
Updated:  September 10, 2026 ID: 000011848

Event code: VXR508CTL49 This event code indicates "The NVRAM has corrupted data on <Controller name>."
Updated:  September 10, 2026 ID: 000011847