Skip to main content
VxRail E660F image

VxRail E660F

Connectivity:  Generate Access key
VxRail E660F

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 1393 shown
1393 out of 1393 shown

This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated:  August 10, 2026 ID: 000205512

This article introduces the VxRail VxVerify tool and how to successfully run VxVerify in a VxRail environment.
Updated:  July 31, 2026 ID: 000021527

Event code: VXR508TMP0100 This event code indicates "The system board <name> temperature is less than the lower warning threshold."
Updated:  August 13, 2026 ID: 000011746

Software-Defined Data Center (SDDC) Manager precheck failure Multi-Site Service fails due to pantheon service in a failed state. Service Availability: Check if the service is up and running using command "systemctl status pantheon." As root user, restart the service if required using command "systemctl restart pantheon" from SDDC Manager VM.
Updated:  August 13, 2026 ID: 000420702

Event code: VXR508STOR5 This event code indicates "Redundancy lost.<VD/Enclosure Name>"
Updated:  August 13, 2026 ID: 000011745

Event code: VXR508RDU0013 This event code indicates "Power supply redundancy is degraded."
Updated:  August 13, 2026 ID: 000011744

Event code: VXR508PSU0002 This event code indicates "A predictive failure detected on power supply <number>."
Updated:  August 13, 2026 ID: 000011743

Event code: VXR508SWC4004 This event code indicates "A firmware or software incompatibility detected between iDRAC in slot <number> and CMC."
Updated:  August 13, 2026 ID: 000011742

Event code: VXR508VLT0302 This event code indicates "CPU <number> <name> voltage is greater than the upper warning threshold."
Updated:  August 13, 2026 ID: 000011716

Event code: VXR508VLT0230 This event code indicates "The mezzanine card <number> <name> voltage is less than the lower warning threshold."
Updated:  August 13, 2026 ID: 000011715

Event code: VXR508TMPS0100 This event code indicates "Inlet temperature is above warning level for extended duration."
Updated:  August 13, 2026 ID: 000011712

Event code: VXR508VDR54 This event code indicates "<VD Name> initialization is terminated."
Updated:  August 13, 2026 ID: 000011711

Event code: VXR508PDR211 This event code indicates "<physical disk name> has encountered storage medium error."
Updated:  August 13, 2026 ID: 000011710

Event code: VXR508MEM6003 This event code indicates "Memory device status is non-critical. Memory device location: <location>, Possible memory module event cause: <cause>."
Updated:  August 13, 2026 ID: 000011709

Event code: VXR508VLT0208 This event code indicates "The memory module <number> <name> voltage is greater than the upper warning threshold."
Updated:  August 13, 2026 ID: 000011707

Event code: VXR508VLT0206 This event code indicates "The memory module <number> <name> voltage is less than the lower warning threshold."
Updated:  August 13, 2026 ID: 000011706

Event code: VXR508AMP403 This event code indicates "The <sensor name> sensor state has changed to a warning state with a value of <current> A."
Updated:  August 12, 2026 ID: 000011705

Event code: VXR508VLT0226 This event code indicates "The memory module <name> voltage is greater than the upper warning threshold."
Updated:  August 12, 2026 ID: 000011704

Event code: VXR508VLT0212 This event code indicates "The disk drive bay <name> voltage is less than the lower warning threshold."
Updated:  August 12, 2026 ID: 000011703

Event code: VXR508VDR31 This event code indicates "Controller cache is preserved for missing or offline <VD Name>."
Updated:  August 12, 2026 ID: 000011701

Event code: VXR508BAT0000 This event code indicates "The system board battery is low."
Updated:  August 12, 2026 ID: 000011700

Event code: VXR508TMP1000 This event code indicates "<tempsensor name> exceeded the maximum warning threshold."
Updated:  August 12, 2026 ID: 000011699

Event code: VXR508RDU0021 This event code indicates "Unable to determine the redundancy status of the power supply units."
Updated:  August 12, 2026 ID: 000011697

When configuring an upstream DNS server for a VxRail cluster through API or VxRail plugin-in UI, and the cluster is using VxRail manager as its internal DNS server, the DNS queries are not forwarded to the designated upstream DNS server.
Updated:  August 11, 2026 ID: 000226207

Hosts show a Key Management Service (KMS) warning because attempts to reach the vCenter server on KMIP port 5696 fail; the native provider uses VPXA VPXD ports for trust management, not KMIP.
Updated:  August 11, 2026 ID: 000223385

Remediation is available for a vulnerability that could be exploited by malicious users to compromise the affected systems.
Updated:  August 11, 2026 ID: 000497857

Event code: VXR508VDR8 This event code indicates "<virtual disk> is degraded either because the physical disk drive in the drive group is removed or the physical disk drive added in a redundant virtual drive has failed."
Updated:  August 10, 2026 ID: 000011696

Event code: VXR508FAN0025 This event code indicates "The <sensor name> sensor state has changed to a warning state with a value of <fan speed> RPM."
Updated:  August 10, 2026 ID: 000011695

Event code: VXR508TMPS0101 This event code indicates "Inlet temperature is above critical level for extended duration."
Updated:  August 10, 2026 ID: 000011693

Event code: VXR508VDR100 This event code indicates "<virtual disk> is unavailable because of incompatibilities with the current controller."
Updated:  August 10, 2026 ID: 000011692