DSA-2020-147: Dell Server Platform Security Advisory for the 2020.1 Intel Platform Updates (June 2020) - Intel SSD - CVE-2020-0527
Updated:  May 06, 2026 ID: 000177610

Dell EMC guidance to mitigate risk and resolution for the iDRAC multiple vulnerabilities. For specific information about affected iDRAC versions and next steps to apply the updates, see this guide.
Updated:  May 05, 2026 ID: 000177031

VxRail Manager Appliance View shows "No Hosts Available" when bandwidth throttling is changed from the default advanced setting to NONE.
Updated:  May 08, 2026 ID: 000182752

Multiple hosts seeing high CRC errors leading to vSAN latency.
Updated:  May 08, 2026 ID: 000182663

Event code: VXR500PDR1116 This event code indicates "Drive <number> is removed."
Updated:  May 07, 2026 ID: 000013476

Event code: VXR500PST0130 This event code indicates "Memory is configured, but not usable."
Updated:  May 07, 2026 ID: 000013475

Event code: VXR500PST0129 This event code indicates "Memory is detected, but is not configurable."
Updated:  May 07, 2026 ID: 000013474

Event code: VXR500PDR20 This event code indicates "SMART configuration change for <PD Name>."
Updated:  May 07, 2026 ID: 000013467

Event code: VXR500CTL12 This event code indicates "An invalid SAS configuration has been detected on <Controller name>. Details: <error message>"
Updated:  May 07, 2026 ID: 000011714

Event code: VXR500ENC18 This event code indicates "Communication with <enclosure name> was lost."
Updated:  May 07, 2026 ID: 000011713

Event code: VXR500PDR110 This event code indicates "The <PCIe solid state device name> reliability has degraded."
Updated:  May 07, 2026 ID: 000011698

Event code: VXR500FAN0026 This event code indicates "The <sensor name> sensor detected an error with a value of <fan speed> RPM."
Updated:  May 07, 2026 ID: 000011694

When the PS1010/PS1030 NVMe SSD or Samsung SATA 883/893 is installed, PSOD may occur during production or gathering operating system (OS) logs or TSR logs.
Updated:  May 07, 2026 ID: 000251344

The VxRail upgrade on a cluster with vLCM enabled fails when it begins to upgrade the nodes. The error message received is "Failed getting host recommendation from DRS to enter maintenance mode for cluster."
Updated:  May 07, 2026 ID: 000340543

Enabling Data-In-Transit Encryption on a vSAN Stretched Cluster causes the Witness Host to go into a partitioned state.
Updated:  May 07, 2026 ID: 000217266

After upgrading vCenter from 7.0U3 to 8.0U1c, Skyline Health triggers alert vSAN Cluster Configuration Consistency.
Updated:  May 07, 2026 ID: 000220633

Event VXR500BAT0021 indicates that the battery has reached the end of its life.
Updated:  May 07, 2026 ID: 000182374

CMOS Battery replacements for Basic Warranty contracts are under warranty through Dell for up to 1 year. This article outlines how to order and replace CMOS batteries once these batteries are no longer under warranty and replaced by Dell.
Updated:  May 07, 2026 ID: 000227359

How to find the installed Security Technical Implementation Guidelines (STIG) version in a VxRail cluster.
Updated:  May 07, 2026 ID: 000321694

VxRail license compliance prechecks before upgrading to 9.0.
Updated:  May 06, 2026 ID: 000310965

vSphere 7.x and later ESXi host experiences a Purple Screen of Death (PSOD) creates a Zdump core dump that is auto‑encrypted. This happens when the host is using Virtual Machine encryption.
Updated:  May 06, 2026 ID: 000393489

Dell PowerEdge Toshiba MG08 and MG09 hard drives may encounter uninterruptible Background Media Scanning (BMS), causing I/O errors, or timeouts.
Updated:  May 06, 2026 ID: 000414662

16G BOSS N1; logs VLT0204 (BOSS CPLD voltage out of range) or VLT0205. Affected Complex Programmable Logic Device (CPLD) versions: v1.2.6 on R660/R760 (VE-660 / VP/VS-760)
Updated:  May 06, 2026 ID: 000390189

This is a vMotion issue, which fails due to general error or source host vMotion network error, even though vMotion VMkernel port is properly configured.
Updated:  May 06, 2026 ID: 000225285

There are two common configuration changes that must be made to a VxRail cluster in order for virtual machines to be deployed with or upgraded to Windows 11.
Updated:  May 06, 2026 ID: 000390644

The HTML 5 VxRail plugin was introduced in 4.7.100. Under certain circumstances, the VxRail plugin must be reinstalled. This article has the official attachments from VxRail Escalation Engineering for the VxRail 4.7.x, 7.x, and 8.x releases.
Updated:  May 06, 2026 ID: 000182936

Dell VxRail remediation is available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.
Updated:  May 06, 2026 ID: 000456372

This article explains the different upgrade behaviors for various types of vSphere Distributed Switches (vDS) during VMware Cloud Foundation (VCF) on VxRail upgrade processes.
Updated:  May 05, 2026 ID: 000423028

This guide details how to collect Node Image Management (NIM) logs in order to troubleshoot NIM reimage failures.
Updated:  May 05, 2026 ID: 000389019

During initial cluster validation and host addition to an existing cluster, all affected nodes reported a NIC driver compliance error related to nic card.
Updated:  May 05, 2026 ID: 000431782