Articles
Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*
30 out of 1354 shown
1354 out of 1354 shown
DSA-2020-147: Dell Server Platform Security Advisory for the 2020.1 Intel Platform Updates (June 2020) - Intel SSD - CVE-2020-0527
Updated: May 06, 2026
ID: 000177610
Dell EMC guidance to mitigate risk and resolution for the iDRAC multiple vulnerabilities. For specific information about affected iDRAC versions and next steps to apply the updates, see this guide.
Updated: May 05, 2026
ID: 000177031
VxRail Manager is not properly handling resources, and may cause a vCenter crash.
Updated: May 08, 2026
ID: 000182856
VxRail Manager Appliance View shows "No Hosts Available" when bandwidth throttling is changed from the default advanced setting to NONE.
Updated: May 08, 2026
ID: 000182752
Multiple hosts seeing high CRC errors leading to vSAN latency.
Updated: May 08, 2026
ID: 000182663
Due to a virtual machine (VM) Guest OS setting for the VxRail Manager VM in VxRail releases 7.0.010 and the way vCenter identifies the Guest OS a list of VM warnings is triggered while performing compute vMotion. The warnings do not prevent manual or automated DRS vMotion.
Updated: May 08, 2026
ID: 000182655
Disk replacement might fail as new disk was not discovered.
Updated: May 08, 2026
ID: 000182264
Due to a known VMware issue in the virtual storage area network (vSAN) Witness, the internal OEM license of the vSAN Witness becomes unavailable. This leaves the Virtual Witness host in an eval/expired licensing state. This affects VxRail stretched clusters upgrading from 4.5.xxx and 4.7.xxx to 7.0.xxx, no known VMware and VxRail release contains a fix.
Updated: May 07, 2026
ID: 000181908
When a Dell VxRail system was previously upgraded from 4.5.xxx to 4.7.xxx to 7.0.0xx. There is a known VMware vCenter upgrade issue causing upgrade failure to 7.0.10x. The VMware fix is incorporated in 7.0.130 enabling this upgrade path.
Updated: May 07, 2026
ID: 000181898
Event code: VXR500PDR1116
This event code indicates "Drive <number> is removed."
Updated: May 07, 2026
ID: 000013476
Event code: VXR500PST0130
This event code indicates "Memory is configured, but not usable."
Updated: May 07, 2026
ID: 000013475
Event code: VXR500PST0129
This event code indicates "Memory is detected, but is not configurable."
Updated: May 07, 2026
ID: 000013474
Event code: VXR500PDR20
This event code indicates "SMART configuration change for <PD Name>."
Updated: May 07, 2026
ID: 000013467
Event code: VXR500CTL12
This event code indicates "An invalid SAS configuration has been detected on <Controller name>. Details: <error message>"
Updated: May 07, 2026
ID: 000011714
Event code: VXR500PDR110
This event code indicates "The <PCIe solid state device name> reliability has degraded."
Updated: May 07, 2026
ID: 000011698
Event code: VXR500FAN0026
This event code indicates "The <sensor name> sensor detected an error with a value of <fan speed> RPM."
Updated: May 07, 2026
ID: 000011694
When the PS1010/PS1030 NVMe SSD or Samsung SATA 883/893 is installed, PSOD may occur during production or gathering operating system (OS) logs or TSR logs.
Updated: May 07, 2026
ID: 000251344
The VxRail upgrade on a cluster with vLCM enabled fails when it begins to upgrade the nodes. The error message received is "Failed getting host recommendation from DRS to enter maintenance mode for cluster."
Updated: May 07, 2026
ID: 000340543
Enabling Data-In-Transit Encryption on a vSAN Stretched Cluster causes the Witness Host to go into a partitioned state.
Updated: May 07, 2026
ID: 000217266
This is an informative article describing how to test Secure Remote Services or Secure Connect Gateway dial-home functionality available on VxRail 4.7.520 and later versions' plug-in UI.
Updated: May 07, 2026
ID: 000181584
After upgrading vCenter from 7.0U3 to 8.0U1c, Skyline Health triggers alert vSAN Cluster Configuration Consistency.
Updated: May 07, 2026
ID: 000220633
The intent of this KB is to provide the proper course of action to take when the notified mystic code MYSTIC014062/VXR014062 takes place.
Updated: May 07, 2026
ID: 000032455
Code upgrade may fail due to missing var/db/payloads/boot/useropts. This issue can also affect vLCM enablement in VxRail 8.0.31x.
Updated: May 07, 2026
ID: 000271989
Event VXR500BAT0021 indicates that the battery has reached the end of its life.
Updated: May 07, 2026
ID: 000182374
CMOS Battery replacements for Basic Warranty contracts are under warranty through Dell for up to 1 year. This article outlines how to order and replace CMOS batteries once these batteries are no longer under warranty and replaced by Dell.
Updated: May 07, 2026
ID: 000227359
Power Supply Unit (PSU) or Disk cannot be contacted on physical view of the VxRail Manager plug-in, but it is present and working everywhere else.
Updated: May 07, 2026
ID: 000180409
How to find the installed Security Technical Implementation Guidelines (STIG) version in a VxRail cluster.
Updated: May 07, 2026
ID: 000321694
VxRail license compliance prechecks before upgrading to 9.0.
Updated: May 06, 2026
ID: 000310965
vSphere 7.x and later
ESXi host experiences a Purple Screen of Death (PSOD) creates a Zdump core dump that is auto‑encrypted. This happens when the host is using Virtual Machine encryption.
Updated: May 06, 2026
ID: 000393489
Dell PowerEdge Toshiba MG08 and MG09 hard drives may encounter uninterruptible Background Media Scanning (BMS), causing I/O errors, or timeouts.
Updated: May 06, 2026
ID: 000414662