893 out of 893 shown

This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Datacenter Infrastructure products. We carefully evaluate and monitor code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated:  April 21, 2026 ID: 000205512

This article is an accumulation of questions, answers, and information relating to VxRail upgrades.
Updated:  April 21, 2026 ID: 000020129

Error shown in iDRAC virtual console "LIC501: A required license is missing or expired."
Updated:  April 24, 2026 ID: 000189590

A guide for Dell customers on how to change or reset the passwords for VxRail Service VMs.
Updated:  April 24, 2026 ID: 000200881

Step-by-step guide using vCenter to identify failed disk, remove disk or disk group, physically replace the faulted disk, mark the new disk as local, and add a new disk or disk group.
Updated:  April 24, 2026 ID: 000019481

VxRail upgrade failed from 7.0.410 to 8.0.201 with error "Internal Server Error."
Updated:  April 24, 2026 ID: 000224161

Event code: VXR500PCI1321 This event code indicates "A high-severity issue is detected in a component of the bus <bus ID>, device 0, function
Updated:  April 23, 2026 ID: 000011563

Event code: VXR500PCI1319 This event code indicates "A high-severity issue is detected in the SSD bay <bay id>, Slot <slot id>."
Updated:  April 23, 2026 ID: 000011562

Event code: VXR500PST0138 This event code indicates "SuperIO failed."
Updated:  April 23, 2026 ID: 000011561

The "Create NSX Transport Node Collection" task fails when adding a cluster to a workload domain.
Updated:  April 23, 2026 ID: 000249941

VxVerify health-check 'ntp_reach' finds non-reach NTP servers which are configured at vCenter Guest OS level, which could cause vCenter upgrades to fail.
Updated:  April 23, 2026 ID: 000296462

Event code: VXR500PST0192 This event code indicates "Shut-down test failed."
Updated:  April 23, 2026 ID: 000011559

Event code: VXR500PST0144 This event code indicates "Unable to load required BIOS files."
Updated:  April 23, 2026 ID: 000011557

Event code: VXR500PCI1300 This event code indicates "A front panel diagnostic interrupt was detected."
Updated:  April 23, 2026 ID: 000011552

Event code: VXR500PCI5008 This event code indicates "The Chassis Management Controller (CMC) is unable to communicate with the PCIe switch board."
Updated:  April 23, 2026 ID: 000011551

Event code: VXR500PDR1024 This event code indicates "Drive mismatch detected for drive <number> in disk drive bay <bay>."
Updated:  April 23, 2026 ID: 000013473

Event code: VXR500PST0196 This event code indicates "Incorrect memory configuration."
Updated:  April 23, 2026 ID: 000013472

Event code: VXR500PDR117 This event code indicates "The <PCIe solid state device name> has turned off because the critical temperature threshold is exceeded."
Updated:  April 23, 2026 ID: 000013469

This article details how to check the system BIOS for enabled or disabled physical ports and enabled or disabled ports within the ESXi hypervisor.
Updated:  April 23, 2026 ID: 000211370

Dell VxRail remediation is available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.
Updated:  April 23, 2026 ID: 000456372

Software Defined Datacenter (SDDC) Manager requires one Transport Zone to be tagged for VMware Cloud Foundation (VCF) to handle it. Multiple tagged zones cause this failure; removing tags from unused transport zones resolves this issue.
Updated:  April 21, 2026 ID: 000223783

VxRail does not support the route based on IP hash load-balancing policy. The day2 node add validation fails if the management port group chooses that policy.
Updated:  April 21, 2026 ID: 000236639

This KB article discusses how to enable TRIM/UNMAP on all ESXi hosts on the vSAN cluster to reclaim space on the vSAN datastore.
Updated:  April 21, 2026 ID: 000194883

Event code: VXR500PST0128 This event code indicates "No memory is detected."
Updated:  April 21, 2026 ID: 000013468

The Physical view is not working, or nodes are missing from the host page due to incorrect vmk layout.
Updated:  April 21, 2026 ID: 000202434

Node health-check fails for test dcism. Test 'dcism' is a health-check that runs on each VxRail node to attempt to validate the status of the dcism service.
Updated:  April 21, 2026 ID: 000193300

Unable to place any host in the cluster into maintenance mode or vMotion due to certificate issues.
Updated:  April 21, 2026 ID: 000185384

The 'df_service' test checks the local Service datastore available capacity on each node.
Updated:  April 21, 2026 ID: 000181119

Event code: VXR500PDR215 This event code indicates "Copyback task to <physical disk name> has failed."
Updated:  April 21, 2026 ID: 000011549

Event code: VXR500PCI1312 This event code indicates "An EISA fail-safe time-out was detected."
Updated:  April 21, 2026 ID: 000011548