Skip to main content

VxRail Software

VxRail Software

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 1424 shown
1424 out of 1424 shown

On December 10, 2021, a critical remote code vulnerability was published concerning the Apache Log4j library. Later, CVE-2021-45046 was reported. VxRail is impacted by these vulnerabilities. Fixes and workarounds for CVE-2021-44228 and CVE-2021-45046 are documented in the tables included in this article.
Updated:  May 12, 2026 ID: 000194466

This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Datacenter Infrastructure products. We carefully evaluate and monitor code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated:  May 11, 2026 ID: 000205512

Event code: VXR500PCI2002 This event code indicates "A fatal IO error detected on a component at slot <number>."
Updated:  May 13, 2026 ID: 000013545

Event code: VXR500FAN0003 This event code indicates "Fan <number> RPM is greater than the upper critical threshold."
Updated:  May 13, 2026 ID: 000013543

Event code: VXR500PCI1320 This event code indicates "A bus fatal error was detected on a component at bus <bus> device <device> function <func>."
Updated:  May 13, 2026 ID: 000013542

Event code: VXR500CTL59 This event code indicates "<Controller name> SAS expander error: <args>"
Updated:  May 13, 2026 ID: 000013541

Event code: VXR500PCI1358 This event code indicates "A fatal error was detected on a component at slot <number>."
Updated:  May 13, 2026 ID: 000013539

Event code: VXR500PCI3006 This event code indicates "Failed to get Link Tuning or FlexAddress data from iDRAC."
Updated:  May 13, 2026 ID: 000013538

Event code: VXR500CTL90 This event code indicates "<controller name> is not operating in Fault Tolerant Mode because of an incompatible peer controller."
Updated:  May 13, 2026 ID: 000013536

Event code: VXR500PCI1354 This event code indicates "A bus correctable error was detected on a component at slot <number>."
Updated:  May 13, 2026 ID: 000013535

Event code: VXR500PCI3004 This event code indicates "Device option ROM on mezzanine card <number> failed to support Link Tuning or FlexAddress."
Updated:  May 13, 2026 ID: 000013534

Event code: VXR500PCI3000 This event code indicates "Device option ROM on embedded NIC failed to support Link Tuning or FlexAddress."
Updated:  May 13, 2026 ID: 000013533

This article provides several options to make a browser trust the VxRail Manager certificate.
Updated:  May 13, 2026 ID: 000197583

This knowledge base article provides a common list of Error messages and recommended solutions for CloudIQ Pre-Check, Download or Update operations.
Updated:  May 13, 2026 ID: 000197490

Event code: VXR500FAN1000 This event code indicates "<Fan Sensor Name> was removed."
Updated:  May 13, 2026 ID: 000013532

Event code: VXR500CTL44 This event code indicates "Diagnostic message <message> from <Controller name>"
Updated:  May 13, 2026 ID: 000013518

Event code: VXR500PCI3002 This event code indicates "Failed to program virtual MAC address on a component at bus <bus> device <device> function <func>."
Updated:  May 13, 2026 ID: 000013517

Event code: VXR500PDR63 This event code indicates "A bad disk block on <physical disk> cannot be reassigned during a write operation."
Updated:  May 13, 2026 ID: 000013516

Event code: VXR500PDR12 This event code indicates "<PD Name> initialization has failed."
Updated:  May 13, 2026 ID: 000013514

Event code: VXR500PST0254 This event code indicates "General failure after video."
Updated:  May 13, 2026 ID: 000013513

Event code: VXR500PDR85 This event code indicates "Security subsystem errors detected for <physical disk>."
Updated:  May 13, 2026 ID: 000013512

This article provides different methods to find the product-serial number tag (PSNT) of a node.
Updated:  May 13, 2026 ID: 000197326

When adding nodes to a cluster the operation fails on building the disk group, but the task is still running in vSphere.
Updated:  May 13, 2026 ID: 000196967

When spare capacity in PowerFlex is smaller than the size of the largest Fault Set, PowerFlex alerts the user. Increasing the spare capacity helps clear this alert.
Updated:  May 13, 2026 ID: 000223578

Different scenarios are applicable depending on the existing connectivity configuration when planning the upgrade to VxRail 7.0.350 or later. These scenarios should be discussed before the upgrade to ensure that the infrastructure is ready for a smooth transition.
Updated:  May 13, 2026 ID: 000196945

Ensure vCLS VMs are deleted before VxRail cluster shutdown operation.
Updated:  May 13, 2026 ID: 000196884

Dell Storage Simple Support Matrices on E-Lab Navigator provide the optimal interoperability for your storage solution.
Updated:  May 13, 2026 ID: 000126411

This article shows how to use the VxRail LCM (Lifecycle Management) retry‑from‑failed‑point feature through the Stoplight API available in versions 7.0.350+ and 4.7.540+. When triggering a retry from the User Interface, LCM reevaluates all previously upgraded components and hosts, which can be time‑consuming especially in larger environments. For VxRail 4.7.540 and above, the API workflow remains the same, although the UI refers to the API interface as Swagger rather than Stoplight.
Updated:  May 13, 2026 ID: 000196755

Dell VxRail upgrades from 4.x to 7.0.x or 8.0.x results in Multicast filtering mode reset. Broadcom vSphere Virtual Distributed Switch (VDS) upgrades affect Microsoft Network Load Balancing (NLB).
Updated:  May 13, 2026 ID: 000196307

This article outlines the response from VxRail Engineering to the security issue described in VMware Security Advisory VMSA-2022-0004 and recommendations to fix or mitigate against the issue.
Updated:  May 13, 2026 ID: 000196304