This article explains the cause and resolution of alerts related to the Baseboard Management Controller (BMC), also known as iDRAC on Dell PowerEdge-based platforms. The BMC is an embedded controller that monitors system health parameters such as temperature, fan speeds, power status, and voltage. When the BMC becomes unresponsive or fails, the Data Domain system generates an alert.
Updated: December 16, 2025
ID: 000203937
VMware vSphere 6.7 Support for IDPA / PowerProtect DP Series Appliance Customers running IDPA / PowerProtect DP Series Software 2.5 -2.7.2
Updated: December 10, 2025
ID: 000204489
Broadcom released Knowledge Base (KB) article 369707 to work around CVE-2024-37085 for ESXi 7 system as part of their Security Advisory VMSA-2024-0013. This article provides a procedure to apply it on PowerProtect Data Protection (DP) Appliances or Integrated Data Protection Appliance (IDPA) Hypervisor (ESXi) system.
Updated: December 29, 2025
ID: 000409401
Dell PowerProtect DP Series Appliance (IDPA) remediation is available for multiple security vulnerabilities in Infrastructure that could be exploited by malicious users to compromise the affected system.
Updated: December 24, 2025
ID: 000368282
Dell Data Protection Central remediation is available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.
Updated: December 22, 2025
ID: 000406763
After upgrading the IDPA appliance model DP4400 to v2.7.9 (Data Domain Operating System 8.3.1), SupportAssist registration fails with "Access Key and Pin is not valid" due to a mismatch in serial number properties.
Updated: December 22, 2025
ID: 000387778
Upgrading IDPA to 2.7.7 or Griffin (Avamar and Data Domain) causes random backup failures due to rejected connections in Data Domain from Object Existence Check (OEC).
Updated: December 16, 2025
ID: 000253286
Dell Data Domain Virtual Edition (DDVE) based platforms (for example, DD3300) Alert for a failed, unknown, or predictive failure disk with the Error: EVT-STORAGE-00031 or EVT-STORAGE-00032
Updated: December 16, 2025
ID: 000203825
Issue reported in IDPA 2.3
IDPA system manager root password goes out of sync frequently after updating the correct password on ACM Dashboard.
Updated: December 15, 2025
ID: 000181995
This knowledge base (KB) article provides a solution to address the Exchange backup error "List of selected targets is empty."
Updated: December 11, 2025
ID: 000041008
This alert shows following an IDPA code upgrade to IDPA 2.7.6, and may or may not affect running services or system access.
Updated: December 10, 2025
ID: 000227457
(CVE-2021-21510) - Dell EMC iDRAC9 versions prior to IDPA 2.7.2 contain a host header injection vulnerability. A remote unauthenticated attacker may potentially exploit this vulnerability by injecting arbitrary 'Host' header values to poison a web-cache or trigger redirections.
After IDPA v.2.7.2 upgrade, connection to iDRAC using only Fully Qualified Domain Name (FQDN) will fail to connect. Connecting using IP works as intended.
Updated: December 09, 2025
ID: 000197115
During post 2.7 upgrade tasks, the Avamar and Appliance Configuration Manager (ACM) both trigger Avamar maintenance tasks which may cause one of them to fail.
Updated: December 03, 2025
ID: 000191190
How to properly shut down an IDPA appliance using Appliance Configuration Manager (ACM) Dashboard and integrated Dell Remote Access Controller (iDRAC) interface.
Updated: December 03, 2025
ID: 000184357
DPATOOLS utility is installed on ACM in a DP4400 appliance and this utility can be used to perform Firmware Upgrades on the IDPA. This KB walks you through an issue where IDPA would fail to enter service mode when you issue the command "dpacli -servicemode" due to DPA being in unconfigured state and DPACLI still issues a test connection query to DPA which fails. This is a known issue with the dpacli 2.0.0.16 version.
Updated: December 02, 2025
ID: 000168734
Dell Avamar, Dell Networker Virtual Edition (NVE) and Dell PowerProtect DP Series Appliance / Dell Integrated Data Protection Appliance (IDPA) remediation is available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.
Updated: November 28, 2025
ID: 000245131
This KB article discusses an issue where a parser error is seen while reading the InfrastructureComponents.xml file due to this file being corrupt or incorrectly populated.
Updated: November 28, 2025
ID: 000173593
The Dell EMC PowerProtect DP Series Appliance Info Hubs organize the documentation for all releases. Note that the “Integrated Data Protection Appliance (IDPA)” is rebranded to “PowerProtect DP Series Appliance”.
Updated: November 26, 2025
ID: 000183645
All Dell Data Domain (DD) systems use SAS connectivity to provide path redundancy (multipath) for attached enclosures and disks. If communication is interrupted along any part of the SAS path, the system generates alerts to notify administrators of potential issues. Prompt attention to these alerts is essential to maintain system health and data availability.
Updated: November 17, 2025
ID: 000204344
Dell Response to the May 25, 2021 VMware vCenter Vulnerability Disclosure
Updated: November 12, 2025
ID: 000188314
AVAMARESC-2383
There is a defect happening on all Avamar UI versions, it could cause the whole UI page to be stuck.
Updated: November 06, 2025
ID: 000227290
Dell EMC Integrated Data Protection Appliance (PowerProtect DP Series) remediation is available for the Apache Log4j Remote Code Execution Vulnerability that may be exploited by malicious users to compromise the affected system. Dell recommends implementing this remediation as soon as possible in light of the critical severity of the vulnerability.
Updated: November 06, 2025
ID: 000194532
Dell Avamar, Dell NetWorker Virtual Edition (NVE), and Dell PowerProtect DP Series Appliance: Dell Integrated Data Protection Appliance (IDPA) remediation is available for multiple vulnerabilities that may be exploited by malicious users to compromise the affected system.
Updated: November 06, 2025
ID: 000201576
Dell Avamar, Dell NetWorker Virtual Edition (NVE), and Dell PowerProtect DP Series Appliance or Dell Integrated Data Protection Appliance (IDPA) remediation is available for multiple vulnerabilities that may be exploited by malicious users to compromise the affected system.
Updated: November 06, 2025
ID: 000208261
Dell Avamar, Dell NetWorker Virtual Edition (NVE) and Dell PowerProtect DP Series Appliance /Integrated Data Protection Appliance (IDPA) remediation is available for multiple vulnerabilities that could be exploited by malicious users to compromise the affected system.
Updated: November 06, 2025
ID: 000213738
Dell Avamar, Dell NetWorker Virtual Edition (NVE) and Dell PowerProtect DP Series Appliance /Integrated Data Protection Appliance (IDPA) remediation is available for multiple vulnerabilities that could be exploited by malicious users to compromise the affected system.
Updated: November 06, 2025
ID: 000227573
Dell Avamar, Dell Networker Virtual Edition (NVE) and Dell PowerProtect DP Series Appliance /Integrated Data Protection Appliance (IDPA) remediation is available for multiple vulnerabilities that could be exploited by malicious users to compromise the affected system.
Updated: November 06, 2025
ID: 000283460
The NVRAM and its Battery Backup Unit (BBU) are critical components of the Data Domain Data Invulnerability Architecture. The Data Domain Operating System (DDOS) monitors these components. If a hardware fault occurs, DDOS generates an alert that must be addressed immediately to maintain system integrity.
Updated: October 31, 2025
ID: 000204334
Data Domain (DD) systems actively monitor hardware health. If a fan fails, is removed, or becomes unreachable, the system posts an alert to indicate a cooling fault. This article explains the symptoms, causes, and resolution steps for fan-related alerts.
Updated: October 31, 2025
ID: 000204300
This article explains the cause and recommended action for alert ENVIRONMENT-00032, which indicates a failure in the storage processor on a Data Domain system. The alert generally indicates a hardware fault on the system motherboard.
Updated: October 31, 2025
ID: 000203873