In some migration scenarios, the OpenManage Enterprise 4.0 target import operation may fail with an error 'Failed to decrypt backup archive' during migration. Use the following article to help in troubleshooting this scenario and various ways to address the failure.
Updated:  May 19, 2026 ID: 000221490

The Dell HBA465e or HBA355e SAS host bus adapter (HBA) may be supplied as a drop in box (DIB) item alongside PowerEdge servers. This article provides direction on selecting an appropriate PCI-e slot.
Updated:  May 19, 2026 ID: 000220555

This article provides information about PERC ECC messages that are seen due to firmware memory handling issues.
Updated:  May 20, 2026 ID: 000223832

PERC H750, H755, and H755N controllers may experience single or multi-bit ECC messages.
Updated:  May 20, 2026 ID: 000223831

Microsoft Hyper-V Virtual Machine (VM) Live Migration may fail or no LUNs are mapped after powering on VMs due to Windows architecture and hardware configuration limiting the number of vFC LUNs.
Updated:  May 20, 2026 ID: 000223671

PowerEdge customers using Broadcom NXE adapters in VMware ESXi may experience unexpected results when attempting to tune port parameters. Particularly in configurations with multiple NXE adapters present, understanding the port ordering from both a VMware (vmnicX) and serverPCI-e Slot-Bus-Device-Function (SBDF) may be helpful to select the appropriate commands.
Updated:  May 20, 2026 ID: 000223479

Dell PowerEdge server with a Broadcom BCM57414 PCIe adapter could encounter intermittent network-disconnected problem in a VMware NSX-T environment.
Updated:  May 20, 2026 ID: 000223469

Dell Intel E810-C adapters do not support disabling the Virtual Machine Device Queue (VMDQ) loopback feature using "Intnetcli" tool.
Updated:  May 20, 2026 ID: 000223462

PowerEdge server intermittently encounters a UEFI iSCSI Boot From SAN (BFS) fatal error 8 upon booting with the PowerStore appliance.
Updated:  May 20, 2026 ID: 000223454

VMware vCenter registration may fail in OMEVV 1.3 with a custom certificate chain installed in OpenManage Enterprise (OME) or vCenter.
Updated:  May 20, 2026 ID: 000223404

Certain PCIe Slots are Gen4 only. A change in the Basic Input Output System (BIOS) has resolved an incorrect reporting in Peripheral Component Interconnect Express (PCIe) capabilities on Gen4 slots. This is not a functional change. The change is cosmetic in nature only.
Updated:  May 20, 2026 ID: 000223307

Slow insertion of a SAS or SATA drive in PowerEdge 15G or 16G Servers with a PERC or HBA controller configuration causes a "No Access" bit to be set, leading to an inability to blink and unblink drives.
Updated:  May 20, 2026 ID: 000222941

On an ESXi host, if the Flow Control setting on the BCM5720 is modified without a cable inserted, the network interface card (NIC) may fail to establish a link when a cable is later inserted. The issue does not occur if the setting is modified with a cable inserted in the NIC port.
Updated:  May 20, 2026 ID: 000222793

Dell Samsung Serial Attached SCSI (SAS) PM1653 and PM1655 solid state drives may report excessive Sense Key faults 0x3, 0x11, 0x0, or 0x4, 0x29, 0x4. These faults have the potential to cause unexpected drive issues.
Updated:  May 20, 2026 ID: 000222201

When installing or restarting the ISM 5.1.1 on an ESXi 8.x environment, the VMK interface for BMC_Network vSwitch gets configured with a DHCP assigned address instead of static.
Updated:  May 20, 2026 ID: 000221985

CPU enumeration change is noticed after BIOS update on 16G Dell PowerEdge AMD Servers.
Updated:  May 19, 2026 ID: 000221896

Dell Enterprise SAS, SATA SSD: SMART predictive failures triggered by remaining write endurance falling below the threshold
Updated:  May 19, 2026 ID: 000221846

This article explains why the Windows Boot Drive (hosting the C:\ volume) may show as removeable media in Windows and how to override the behavior when necessary.
Updated:  May 19, 2026 ID: 000221557

The link speed of a NVIDIA ConnectX-7 Single Port NDR200 may show as Single Data Rate (SDR) in the IDRAC.
Updated:  May 19, 2026 ID: 000221452

After a cold boot of the server, the Intel IPU E2100-CCQDA2 may present PR8 entries in the Lifecycle log.
Updated:  May 19, 2026 ID: 000221450

iDRAC user interface and LSPCI show multiple PCIe Functions for the Intel Infrastructure Processing Unit (IPU) E2100-CCQDA2.
Updated:  May 19, 2026 ID: 000221412

If a bond is created in Linux using the Intel Infrastructure Processing Unit (IPU) E2100-CCQDA2, the bond does not come online.
Updated:  May 19, 2026 ID: 000221411

Network port enumeration on Windows Server 2022 with Dell network adapters may swap port designations.
Updated:  May 19, 2026 ID: 000221408

When in a SNAPI enabled configuration, the Dell Mellanox Ethernet and InfiniBand NICs may display 0000:0000:0000:0000 as the virtual node GUID for the second partition.
Updated:  May 19, 2026 ID: 000221406

Firmware upgrades to Broadcom network devices may fail with a "libpci.so: Cannot open" error when run from a Smart Bootable ISO image created with Dell Repository Manager 3.x.
Updated:  May 19, 2026 ID: 000221180

This article provides three methods to confirm the SSD Piece Part Identification (PPID)
Updated:  May 19, 2026 ID: 000466928

After an update to 7.00.00.00 or higher, the iDRAC9 web server may become inaccessible where the user has uploaded a custom or CA signed web certificate.
Updated:  May 19, 2026 ID: 000220891

If "Automatically restart" under System Failure is disabled inside Windows Server 2019 and 2022, a manual reboot is needed after a bug check or crash, but the system is rebooting automatically.
Updated:  May 19, 2026 ID: 000220429

Increased fan spinning noise. PowerEdge 15G servers equipped with a Dell Intel X710 Open Compute Project (OCP3) Network card after upgrading the Integrated Dell Remote Access Controller (iDRAC) firmware to version 7.00.30.00
Updated:  May 19, 2026 ID: 000219529

The iDRAC is unable to connect to a Server Message Block (SMB) share when the optional "SMB3 share encryption" is enabled.
Updated:  May 19, 2026 ID: 000219260