Skip to main content
PowerEdge R960 image

PowerEdge R960

PowerEdge R960

Articles

Select a category and then a related component to find articles about specific hardware and software.

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 674 shown
674 out of 674 shown

This article describes how to view and clear the system event log (SEL) in System Setup.
Updated:  May 21, 2026 ID: 000226396

This article describes how to find the iDRAC's current MAC address.
Updated:  May 21, 2026 ID: 000226214

Viewing the VLAN details of a deployment template's network settings list devices that are not associated to the template.
Updated:  May 21, 2026 ID: 000227227

This article provides information about Fatal BUS errors seen with PCI1360 and PCI1318.
Updated:  May 21, 2026 ID: 000227163

How to create Cluster Shared Volumes by manually calculating the necessary disk space value.
Updated:  May 21, 2026 ID: 000227068

Dell Intel SATA SSD drives may report a not correctly functioning PDR3 event, potentially resulting in a drive failure condition.
Updated:  May 21, 2026 ID: 000226989

PowerEdge 16G platform is stuck in an endless loop, continuously restarting during the POST at the "configure memory…" stage.
Updated:  May 21, 2026 ID: 000226735

Prerequisites of enabling Intel Trust Domain Extension (TDX) on Dell 16G Intel PowerEdge servers
Updated:  May 21, 2026 ID: 000226452

A UEFI0074 warning is generated in the life cycle Log during Windows installation or after running Windows Update. Microsoft Windows operating systems can update the database and DBX entries to ensure that the platform is up to date per industry security standards.
Updated:  May 21, 2026 ID: 000226358

This article talks about the PERC H965 controller's supported virtual disk stripe sizes.
Updated:  May 21, 2026 ID: 000226265

Updating 16G PowerEdge Server BIOS may result in Secure Boot database updates.
Updated:  May 21, 2026 ID: 000226055

Initiating a graceful restart or shutdown using Redfish APIs may fail for the Windows Server Operating System.
Updated:  May 21, 2026 ID: 000224986

The server fails to power on after a system crash is encountered and LifeCycle Log (LC Log) records a watchdog event from iDRAC.
Updated:  May 21, 2026 ID: 000224883

Dell solid state drive (SSD) fails after system reports low environment operating temperature.
Updated:  May 20, 2026 ID: 000224458

This article provides information about PERC ECC messages that are seen due to firmware memory handling issues.
Updated:  May 20, 2026 ID: 000223832

PERC H750, H755, and H755N controllers may experience single or multi-bit ECC messages.
Updated:  May 20, 2026 ID: 000223831

Microsoft Hyper-V Virtual Machine (VM) Live Migration may fail or no LUNs are mapped after powering on VMs due to Windows architecture and hardware configuration limiting the number of vFC LUNs.
Updated:  May 20, 2026 ID: 000223671

The issue is cosmetic. There is no functional impact. The lspci -v command requires certain labels to read. Labels are missing from the current Basic Input Output System (BIOS) but are added to June block BIOS v2.2.4.
Updated:  May 20, 2026 ID: 000223577

PowerEdge customers using Broadcom NXE adapters in VMware ESXi may experience unexpected results when attempting to tune port parameters. Particularly in configurations with multiple NXE adapters present, understanding the port ordering from both a VMware (vmnicX) and serverPCI-e Slot-Bus-Device-Function (SBDF) may be helpful to select the appropriate commands.
Updated:  May 20, 2026 ID: 000223479

Dell PowerEdge server with a Broadcom BCM57414 PCIe adapter could encounter intermittent network-disconnected problem in a VMware NSX-T environment.
Updated:  May 20, 2026 ID: 000223469

Dell Intel E810-C adapters do not support disabling the Virtual Machine Device Queue (VMDQ) loopback feature using "Intnetcli" tool.
Updated:  May 20, 2026 ID: 000223462

PowerEdge server intermittently encounters a UEFI iSCSI Boot From SAN (BFS) fatal error 8 upon booting with the PowerStore appliance.
Updated:  May 20, 2026 ID: 000223454

VMware vCenter registration may fail in OMEVV 1.3 with a custom certificate chain installed in OpenManage Enterprise (OME) or vCenter.
Updated:  May 20, 2026 ID: 000223404

Dell PowerEdge 16G: VMware vSphere Error: Skipping interrupt routing entry with bad device number: 176
Updated:  May 20, 2026 ID: 000223051

Slow insertion of a SAS or SATA drive in PowerEdge 15G or 16G Servers with a PERC or HBA controller configuration causes a "No Access" bit to be set, leading to an inability to blink and unblink drives.
Updated:  May 20, 2026 ID: 000222941

On an ESXi host, if the Flow Control setting on the BCM5720 is modified without a cable inserted, the network interface card (NIC) may fail to establish a link when a cable is later inserted. The issue does not occur if the setting is modified with a cable inserted in the NIC port.
Updated:  May 20, 2026 ID: 000222793

Dell Samsung Serial Attached SCSI (SAS) PM1653 and PM1655 solid state drives may report excessive Sense Key faults 0x3, 0x11, 0x0, or 0x4, 0x29, 0x4. These faults have the potential to cause unexpected drive issues.
Updated:  May 20, 2026 ID: 000222201

Dell PowerEdge Server: 15G and 16G Intel-based systems may fail with bugcheck 0x139 after installing the Intel chipset drivers or Matrox video driver.
Updated:  May 20, 2026 ID: 000222177

When installing or restarting the ISM 5.1.1 on an ESXi 8.x environment, the VMK interface for BMC_Network vSwitch gets configured with a DHCP assigned address instead of static.
Updated:  May 20, 2026 ID: 000221985

No option to disable Virtualization Technology or x2APIC in F2 system setup under processor settings. This occurs when a system is populated with four processors.
Updated:  May 20, 2026 ID: 000221937