This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated: August 24, 2026
ID: 000502480
This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated: August 24, 2026
ID: 000205512
PDF compliance report generation fails with a timeout and an ArrayIndexOutOfBoundsException error in PowerFlex Manager 5.1.0.0. To restore PDF functionality, PFMP must be upgraded.
Updated: August 24, 2026
ID: 000502475
This article explains the command switch_cluster_mode to change the MDM cluster to 1 or 3 or 5 node cluster
Updated: August 24, 2026
ID: 000502467
Dell PM1735a Non-Volatile Memory Express (NVMe) drive failing in PowerEdge servers.
Updated: August 24, 2026
ID: 000481601
This article provides a procedure to resolve the condition documented in Cisco bug CSCwa04181 that impacts the size of the bootflash partition on Nexus N9K-C92348GC-X switches.
Updated: August 24, 2026
ID: 000212965
This article lists the PowerFlex hardware End of expansion (EOexp) and Software End of Standard Support (EoSS) codes.
Updated: August 24, 2026
ID: 000305299
This article details how to collect logs from PowerFlex Manager (3.8, 4.x 5.x), iDRAC8\iDRAC9 SupportAssist, Get Info on MDM SDS, Gateway, CloudLink, and VMware ESXi hosts.
Updated: August 24, 2026
ID: 000205078
Running command svm status connection is showing both CloudLink nodes as Inaccessible due to blocked port UDP 1194.
Updated: August 24, 2026
ID: 000384973
This article has information about the KMIP CA Certificate is expired alarm.
Updated: August 24, 2026
ID: 000344961
Unable to apply PowerFlex license, receive error code ASMCOMMONS.0070.
Updated: August 20, 2026
ID: 000227818
This article explains how to renew the cluster node certificate when CloudLink is showing the alarm "Cluster node certificate is expired."
Updated: August 20, 2026
ID: 000233517
PowerFlex Manager 4.x may show false alerts—CONFIGURED_SPARE_CAPACITY_SMALLER_THAN_LARGEST_FAULT_UNIT, STORAGE_POOL_UNBALANCED, NOT_ENOUGH_FAULT_UNITS_IN_SP due to a known software issue pending fix.
Updated: August 20, 2026
ID: 000279687
This article shows the PowerFlex release matrix, and guidance on how to correlate the various packages.
Updated: August 19, 2026
ID: 000461757
Software Defined Storage (SDS) on a server panics, showing “data degraded”, losing Client (SDC) volume access and O. The panic is due to a kernel futex race‑condition issue, causing unavailability.
Updated: August 19, 2026
ID: 000281636
The system reports repeated SDS disconnection and possibly I/O errors appearing on the clients.
Updated: August 19, 2026
ID: 000058476
ASR0000 appears when the hardware watchdog timer expires after iDRAC Service Module communication ends, caused by loss of iDRAC‑host OS connectivity, such as a powered‑off host or a degraded module.
Updated: August 19, 2026
ID: 000219431
SDC is failing to start scini service with insmod error: "could not insert module ../scini.ko: Required key not available."
UEFI Secure Boot is enabled or the kernel parameter module.sig_enforce is set on the SDC host. This configuration is not supported for PowerFlex deployment.
Updated: August 18, 2026
ID: 000227045
During maintenance operations on the PowerFlex Management Cluster (PFMC), the SDS node fails to exit and remains in Protected Maintenance Mode (PMM), as MDM rejects the request and returns the error SDS_MAINTENANCE_MODE_EXIT_FAILED with the message "The wrong maintenance mode type was chosen for this SDS".
Updated: August 18, 2026
ID: 000501252
PowerFlex Rack remediation is available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.
Updated: August 18, 2026
ID: 000498657
This article explains the meaning of Dial Home Symptom code SIO02.04.0000009 and how to troubleshoot it.
Updated: August 17, 2026
ID: 000381561
Scli login fails with "Error: Failed to connect to MDM 127.0.0.1:8611"
Scenario
Updated: August 17, 2026
ID: 000203269
SupportAssist is connected; however AIOps (formerly known as CloudIQ (CIQ)) shows the 'Last Contacted' time as days or weeks ago.
Updated: August 17, 2026
ID: 000399850
This article explain how to replace a failed drive in a deployed node. PowerFlex Manager supports the replacement of SSD and NVMe drives for PowerFlex storage-only nodes and hyperconverged nodes.
Updated: August 17, 2026
ID: 000382343
This article explains the procedure to perform a clean Shut Down or Startup of a PowerFlex system running in ESXi or Two Tier Environment.
Updated: August 17, 2026
ID: 000021739
This article contains the initial steps to take on all PowerFlex performance-based issues when observing performance degradation, low Input Output Operations Per Second (IOPs), low MB per sec, or high latency.
Updated: August 17, 2026
ID: 000220627
This article explains how to Calculate Spare Capacity
Updated: August 17, 2026
ID: 000065593
This article explains the calculation for storage pool free capacity in PowerFlex.
Updated: August 17, 2026
ID: 000195170
There is a security vulnerability in the log4j files that are contained on both the PowerFlex Gateway and Presentation Server. This article describes the steps to take to work around the issue.
Updated: August 17, 2026
ID: 000194498
How to get the Firmware version and other details of any device on a Dell PowerEdge server using racadm.
Updated: August 17, 2026
ID: 000023762