Skip to main content
OEMR R5500 image

OEMR R5500

OEMR R5500

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 143 shown
143 out of 143 shown

This article provides guidance for the Dell System Update (DSU).
Updated:  June 01, 2026 ID: 000130590

This article explains how to create and import an iDRAC certificate.
Updated:  May 28, 2026 ID: 000120158

How to Identify the physical slot number in iDRAC based off the device name in vSphere/VSAN.
Updated:  June 01, 2026 ID: 000179543

The below article is a workaround mechanism to recover PowerEdge systems from critical log entry "SWC5008 Unable to access Front LED Panel because of a hardware error condition" for a few versions of the iDRAC.
Updated:  May 25, 2026 ID: 000205597

This article provides steps to troubleshoot a chassis intrusion, chassis open message for PowerEdge servers.
Updated:  May 25, 2026 ID: 000136481

Dell PowerEdge Toshiba MG08 and MG09 hard drives may encounter uninterruptible Background Media Scanning (BMS), causing I/O errors, or timeouts.
Updated:  May 24, 2026 ID: 000381662

This article provides information about how to verify if a Network Interface Card (NIC) is compatible with a PowerEdge Server.
Updated:  May 23, 2026 ID: 000349619

This article provides information about CPU Machine Check errors and common causes and proper handling when errors are seen.
Updated:  May 23, 2026 ID: 000349127

Unsure about the procedure to update a specific component's firmware in a PowerEdge system? Learn how to in this specific article.
Updated:  May 23, 2026 ID: 000333712

Dell Samsung PM893 SSDs with Firmware HJ55 or Earlier Experience Premature SMART Failures
Updated:  May 23, 2026 ID: 000333265

R7725, R6725, R7715, and R6715 the number of CPU Cores is not recognized correctly.
Updated:  May 23, 2026 ID: 000321587

The "Predictive failure reported for disk x" error continues to be logged every 24 hours, even after the identified drive has been replaced. The issue only affects drives connected to PERC Controllers in RAID configuration.
Updated:  May 23, 2026 ID: 000308774

PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
Updated:  May 22, 2026 ID: 000256907

DSU and SUU may not inventory any server components due to a crash caused in the invcol.exe module. Inventory Collector 24.09 and newer is no longer fully compatible with Windows Server 2016.
Updated:  May 22, 2026 ID: 000251806

CPUs can be perceived to be hot while server is idle.
Updated:  May 22, 2026 ID: 000250878

iDRAC Service Module (iSM) 5.4 and older versions fail to upload SupportAssist collections back to Dell. A "handshake API" error occurs. This upload feature has been deprecated due to the receiving servers at Dell had been decommissioned.
Updated:  May 21, 2026 ID: 000240336

The Dell SS540 SAS solid state drive is reported as not correctly functioning.
Updated:  May 21, 2026 ID: 000237298

Attempts to update the Broadcom NetXtreme 5719 and 5720 Network Interface Card (NIC) using the .bin file with sudo in Linux results in an 'Inventory Collection Failure' error.
Updated:  May 21, 2026 ID: 000228045

This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server. It is also relevant for 100% fan speeds.
Updated:  May 21, 2026 ID: 000227912

Viewing the VLAN details of a deployment template's network settings list devices that are not associated to the template.
Updated:  May 21, 2026 ID: 000227227

This article describes how to find the iDRAC's current MAC address.
Updated:  May 21, 2026 ID: 000226214

During the power counter roll-over for utilization, the power counter rolls over before the rollover counter. This leads to an erroneous power spike which may throttle the server.
Updated:  May 21, 2026 ID: 000225350

Dell solid state drive (SSD) fails after system reports low environment operating temperature.
Updated:  May 20, 2026 ID: 000224458

Dell Samsung Serial Attached SCSI (SAS) PM1653 and PM1655 solid state drives may report excessive Sense Key faults 0x3, 0x11, 0x0, or 0x4, 0x29, 0x4. These faults have the potential to cause unexpected drive issues.
Updated:  May 20, 2026 ID: 000222201

Dell Enterprise SAS, SATA SSD: SMART predictive failures triggered by remaining write endurance falling below the threshold
Updated:  May 19, 2026 ID: 000221846

In some migration scenarios, the OpenManage Enterprise 4.0 target import operation may fail with an error 'Failed to decrypt backup archive' during migration. Use the following article to help in troubleshooting this scenario and various ways to address the failure.
Updated:  May 19, 2026 ID: 000221490

Network port enumeration on Windows Server 2022 with Dell network adapters may swap port designations.
Updated:  May 19, 2026 ID: 000221408

After an update to 7.00.00.00 or higher, the iDRAC9 web server may become inaccessible where the user has uploaded a custom or CA signed web certificate.
Updated:  May 19, 2026 ID: 000220891

The iDRAC is unable to connect to a Server Message Block (SMB) share when the optional "SMB3 share encryption" is enabled.
Updated:  May 19, 2026 ID: 000219260

BIOS/CPLD or backplane firmware DUP may fail to update when attempted soon after iDRAC restart.
Updated:  May 18, 2026 ID: 000216521