This article introduces the VxRail VxVerify tool and how to successfully run VxVerify in a VxRail environment.
Updated:  July 31, 2026 ID: 000021527

The rules for accounts and passwords implemented by VxRail are explained in this article. Recommendations for VxRail account naming including vCenter ESXi host, VxRail Manager, and Platform Services Controller (PSC) root accounts, general suggestions for accounts password best practices for use in Dell VxRail.
Updated:  July 24, 2026 ID: 000158231

Explore the Dell End of Service Life (EOSL) and End of Life (EOL) list for converged infrastructure, storage, and storage networking products. Access End-of-Life documents for hardware, software, and firmware release and service dates
Updated:  August 10, 2026 ID: 000185734

Remediation is available for a vulnerability that could be exploited by malicious users to compromise the affected systems.
Updated:  August 10, 2026 ID: 000497857

Dell Samsung Serial Attached SCSI (SAS) PM1653 and PM1655 solid state drives may report excessive Sense Key faults 0x3, 0x11, 0x0, or 0x4, 0x29, 0x4. These faults have the potential to cause unexpected drive issues.
Updated:  August 10, 2026 ID: 000222201

This document describes how to validate, install, and manage custom third-party components in VxRail environments using VxRail vLCM. It outlines supported upgrade scenarios, common misconfigurations, and best-practice workflows to ensure reliable VxRail life cycle operations.
Updated:  August 10, 2026 ID: 000419960

Event code: VXR508VDR53 This event code indicates "The consistency check logging of inconsistent parity data is disabled for <virtual disk>."
Updated:  August 07, 2026 ID: 000011684

Event code: VXR508PSU0914 This event code indicates "A predictive failure detected on power unit <number>."
Updated:  August 07, 2026 ID: 000011683

Event code: VXR508VDR99 This event code indicates "<virtual disk> is unavailable because of an ID conflict in the fault-tolerant pair."
Updated:  August 07, 2026 ID: 000011682

Event code: VXR508VLT0218 This event code indicates "The <name> voltage is less than the lower warning threshold."
Updated:  August 07, 2026 ID: 000011681

Event code VXR508TMP1001 This event code indicates "<tempsensor name> has crossed the minimum warning threshold."
Updated:  August 07, 2026 ID: 000011678

Event code: VXR508VLT0224 This event code indicates "The memory module <name> voltage is less than the lower warning threshold."
Updated:  August 07, 2026 ID: 000011677

Event code: VXR508BAT0030 This event code indicates "The system board battery is reading low."
Updated:  August 07, 2026 ID: 000011676

Event code: VXR508TMP503 This event code indicates "The <sensor name> sensor state has changed to a warning state with a value of <temperature> degrees Celsius."
Updated:  August 07, 2026 ID: 000011672

Event code: VXR508VLT0202 This event code indicates "The system board <name> voltage is greater than the upper warning threshold."
Updated:  August 07, 2026 ID: 000011671

Event code: VXR508VLT0300 This event code indicates "CPU <number> <name> voltage is less than the lower warning threshold."
Updated:  August 07, 2026 ID: 000011670

Micron 5x00 Series SSDs may experience read/write performance degradation after reaching approximately 65,535 power-on hours (POH) (~7.5 years of continuous operation). This issue is limited to performance impact only and does not cause data loss or drive failure.
Updated:  August 07, 2026 ID: 000464492

This article explains how to manually associate a vmnic interface with its corresponding uplink number on an ESXi host using the vSphere Client or SSH command line.
Updated:  August 06, 2026 ID: 000223069

This article explains how to modify an iDRAC (Integrated Dell Remote Access Controller) user’s permission to administrator by locating the user ID, logging in with the vxpsvc account via SSH, and executing RACADM commands.
Updated:  August 06, 2026 ID: 000221901

The primary storage provision API (rest/vxm/v1/system/primary-storage) can return a 504 gateway timeout when VM migration to external storage exceeds the default timeout, especially in constrained network environments.
Updated:  August 06, 2026 ID: 000219922

Validation fails on VxRail 8.0.300 and later when the cached discovery VLAN 3939 is not in use which causes a mismatch error.
Updated:  August 06, 2026 ID: 000228813

Event code: VXR508VLT0200 This event code indicates "The system board <name> voltage is less than the lower warning threshold."
Updated:  August 06, 2026 ID: 000011669

Event code: VXR508ENC6 This event code indicates "Communication timeout on <Enclosure Name>."
Updated:  August 05, 2026 ID: 000011665

The vSphere Client’s refresh icon never stops rotating because the system is enrolled in VMware Customer Experience Improvement Program while all external network access is blocked.
Updated:  August 05, 2026 ID: 000228894

User Guide for VxRail Troubleshooting Toolbox (VTT)
Updated:  August 05, 2026 ID: 000214621

Event code: VXR508ENC28 This event code indicates "Enclosure Management Module (EMM) firmware version mismatch detected in <enclosure name>.<EMM 0 version> <EMM 1 version>."
Updated:  August 04, 2026 ID: 000011664

Event code: VXR508ENC5 This event code indicates "Redundancy on <Enclosure Name> is degraded"
Updated:  August 04, 2026 ID: 000011663

Event code: VXR508CTL201 This event code indicates "The current driver version <major version number> (<minor version number>) is older than the required driver version <major version number> (<minor version number>) for <controller name>."
Updated:  August 04, 2026 ID: 000011661

Production VMs on VxRail fail to power on, showing out‑of‑space alerts because their .vmdk files are flat VMFS‑style files stored on a vSAN datastore, which vSAN does not support.
Updated:  August 04, 2026 ID: 000351347

The VxRail deployment page freezes and the VxRail Management Interface (VAMI) shows “Unable to get deployment status” because vCenter cannot reach the DNS server.
Updated:  August 04, 2026 ID: 000340653