Skip to main content
PowerEdge R770AP image

PowerEdge R770AP

PowerEdge R770AP

Articles

Select a category and then a related component to find articles about specific hardware and software.

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 297 shown
297 out of 297 shown

This article provides information about the LIC008 error seen when importing the IDRAC License.
Updated:  May 23, 2026 ID: 000353269

This article provides information about how to verify if a Network Interface Card (NIC) is compatible with a PowerEdge Server.
Updated:  May 23, 2026 ID: 000349619

Kioxia CM6 NVMe SSDs on 17‑generation servers experience I2C (Inter‑Integrated Circuit) communication issues. The fan speed stays locked at 100 % after OS boot. This behavior is observed on 17G servers only running Integrated Dell Remote Access Controller (iDRAC) 10 firmware version 1.20.80.51 or older.
Updated:  May 24, 2026 ID: 000430558

This article provides a high‑level guide to downloading vendor‑specific firmware and drivers for common PowerEdge NICs such as NVIDIA, Broadcom, and Intel. These processes complement Dell Update Packages (DUPs) and are used when vendor‑specific firmware or drivers are required beyond Dell’s updates.
Updated:  May 24, 2026 ID: 000423756

PowerEdge servers do not support operating system installation, or boot from direct CPU‑attached NVMe SSD drives if the metadata format size is not set to 0.
Updated:  May 24, 2026 ID: 000417881

PowerEdge connected Dell NVMe SSDs with the Limited Retry (LR) bit set may experience an increase in failures due to elevated media and data‑integrity error rates.
Updated:  May 24, 2026 ID: 000415896

PowerEdge 14G, 15G, 16G, and 17G servers skip Preboot eXecution Environment (PXE) boot when an "Unavailable" entry is last in the boot order.
Updated:  May 24, 2026 ID: 000396285

Fans reporting FAN0000/FAN0001 errors (RPM below warning or critical) should be removed and swapped to another connector; if the error follows the fan, replace it.
Updated:  May 24, 2026 ID: 000391086

Dell PowerEdge 17G servers added MEMHOT error monitoring in iDRAC10 firmware version 1.20.80.50 combined with supported Field-Programmable Gate Array (FPGA) firmware. Servers configured with Power Supply Cold Redundancy feature enabled can record random SYS565 memory temperature warning events.
Updated:  May 24, 2026 ID: 000388703

Dell PowerEdge 17G Intel servers may record memory module temperature warning events in the Lifecycle Log and System Event Log during the server cold boot sequence.
Updated:  May 24, 2026 ID: 000381690

Encountering PR8 errors in the LifeCycle (LC) log when using a BlueField-3 (BF3) Data Processing Units (DPU) card (DPN: HFWRM).
Updated:  May 24, 2026 ID: 000379421

Dell Micron 7450 and 7500 Non-Volatile Memory Express solid state drives may encounter drive initialization failure due to a firmware issue, resulting in the solid state drives being unrecoverable.
Updated:  May 23, 2026 ID: 000368482

Settings are not saved in UEFI Boot Settings if more than one setting is changed.
Updated:  May 23, 2026 ID: 000366899

This article provides information about CPU Machine Check errors and common causes and proper handling when errors are seen.
Updated:  May 23, 2026 ID: 000349127

When encryption is enabled on BOSS-N1, the system may stop during POST with the message: "No Boot Device Available or Operating System Detected."
Updated:  May 23, 2026 ID: 000342517

Dell Samsung PM893 SSDs with Firmware HJ55 or Earlier Experience Premature SMART Failures
Updated:  May 23, 2026 ID: 000333265

New deployments of OpenManage Enterprise 4.4.0 are experiencing service failures after configuring the time zone for GMT +02:00 Helsinki, Kyiv, Riga, Sofia, Tallinn, Vilnius. The issue is only seen on fresh deployment of OpenManage Enterprise (OME) 4.4.0 on Hyper-V. Deploying OpenManage Enterprise (OME) on other hypervisors is not impacted.
Updated:  May 23, 2026 ID: 000326459

R7725, R6725, R7715, and R6715 the number of CPU Cores is not recognized correctly.
Updated:  May 23, 2026 ID: 000321587

PowerEdge: Dell service support for end of industry production of 2.5" 15k RPM SAS hard drives
Updated:  May 23, 2026 ID: 000314166

This article details the most recent firmware version for Integrated Dell Remote Access Controller 10 (iDRAC10), designed for Dell PowerEdge servers from the 17th generation onwards.
Updated:  May 22, 2026 ID: 000305325

PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
Updated:  May 22, 2026 ID: 000256907

Dust or chemical contamination at the endface of a fiber optic LC connector or transceiver module impedes signaling. Dell engineering teams have verified cases in which a fully functional port appears to be a bad port because dirty optical connectors manifest as a port failing loop testing with acceptable power measurement levels. Cable connectors should be cleaned and when stored must be protected from dust particle or chemical contamination.
Updated:  May 22, 2026 ID: 000246018

The BIOS setting changes may not appear in iDRAC if configured using the F11 Boot Manager on Dell PowerEdge 16G and 17G platforms.
Updated:  May 21, 2026 ID: 000238951

In Windows Server 2025, when leveraging CPUs with more than 256 cores, the Broadcom BCM5720 fails to retrieve a DHCP address, leading to no network connectivity.
Updated:  May 21, 2026 ID: 000233949

The article describes how to troubleshoot network connectivity issues for network cards.
Updated:  May 21, 2026 ID: 000227983

Seagate Skybolt and SkyboltServoBP drive fails with medium format corrupted errors.
Updated:  May 21, 2026 ID: 000227930

This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server. It is also relevant for 100% fan speeds.
Updated:  May 21, 2026 ID: 000227912

This article provides information about Fatal BUS errors seen with PCI1360 and PCI1318.
Updated:  May 21, 2026 ID: 000227163

How to create Cluster Shared Volumes by manually calculating the necessary disk space value.
Updated:  May 21, 2026 ID: 000227068

Dell Intel SATA SSD drives may report a not correctly functioning PDR3 event, potentially resulting in a drive failure condition.
Updated:  May 21, 2026 ID: 000226989