All products: Contaminants such as dust on fiber optic connector end face causes poor IO performance
Dust or chemical contamination at the endface of a fiber optic LC connector or transceiver module impedes signaling. Dell engineering teams have verified cases in which a fully functional port appears to be a bad port because dirty optical connectors manifest as a port failing loop testing with acceptable power measurement levels. Cable connectors should be cleaned and when stored must be protected from dust particle or chemical contamination.
Updated: May 22, 2026
ID: 000246018
The article describes how to troubleshoot network connectivity issues for network cards.
Updated: May 21, 2026
ID: 000227983
CPUs can be perceived to be hot while server is idle.
Updated: May 22, 2026
ID: 000250878
NVIDIA L-series GPUs may fall offline during runtime operations when running vGPU Grid 17.2 drivers.
Updated: May 22, 2026
ID: 000250524
Performance drops after power supply unit (PSU) cable removal and does not recover upon reconnection, despite the A/B Grid Redundant policy being active in iDRAC10.
Updated: May 22, 2026
ID: 000247062
Racadm diagnostics "-m 2" switch returns express diagnostics results only.
Updated: May 22, 2026
ID: 000246053
Inband updates to Open Server Manager (OSM) with .bin DUP results in a watchdog soft lockup error. Update is successful.
Updated: May 22, 2026
ID: 000244474
Dell Update Package (DUP) can randomly fail in Red Hat Enterprise Linux (RHEL) or Ubuntu.
Updated: May 22, 2026
ID: 000242250
The Lifecycle Controller logs reports SPDM0001 and SPDM0003 warning messages after every iDRAC reset.
Updated: May 21, 2026
ID: 000242100
Observing system stop responding or Purple Screen Of Death (PSOD) during ESXi 8.0 U3 installation,
Updated: May 21, 2026
ID: 000241608
Seagate Summit SAS/SATA drives report medium errors or sense key 3/11 on PowerEdge and PowerVault systems due to a firmware issue causing weak writes to a drive sector.
Updated: May 21, 2026
ID: 000239838
The BIOS setting changes may not appear in iDRAC if configured using the F11 Boot Manager on Dell PowerEdge 16G and 17G platforms.
Updated: May 21, 2026
ID: 000238951
In Windows Server 2025, when leveraging CPUs with more than 256 cores, the Broadcom BCM5720 fails to retrieve a DHCP address, leading to no network connectivity.
Updated: May 21, 2026
ID: 000233949
OpenManage Enterprise integration for VMware vCenter may fail to Unmanage hosts with error "UNMANAGE_REMOVE_MEL_FAILURE"
Updated: May 21, 2026
ID: 000233873
When a PS1010 or PS1030 NVMe SSD is installed, a PSOD may occur during production or gathering Operating System (OS) logs.
Updated: May 21, 2026
ID: 000228837
OpenManage Enterprise version 4.1 entitlements feature will no longer work after October 2024 due to the decommissioning of legacy OAUTH APIs. Also, the standalone Dell License Manager application is end-of-life.
Updated: May 21, 2026
ID: 000228401
When editing a deployment template the 'Edit Components' screen is stuck with the 'Loading' animation. Also, when editing a compliance template the 'Template Details' screen is blank.
Updated: May 21, 2026
ID: 000228133
Seagate Skybolt and SkyboltServoBP drive fails with medium format corrupted errors.
Updated: May 21, 2026
ID: 000227930
This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server.
It is also relevant for 100% fan speeds.
Updated: May 21, 2026
ID: 000227912
Connection Status shows disconnected for all devices in OpenManage Enterprise Services (OMES) plugin 4.1.0 under the Site Health tab - Managed Devices page.
Updated: May 21, 2026
ID: 000227514
Multiple SKHynix NVMe (PS1010) drives in the same server experienced PCIe link training failures during the deployment phase, resulting in the drives entering read-only mode.
Updated: May 21, 2026
ID: 000227423
Viewing the VLAN details of a deployment template's network settings list devices that are not associated to the template.
Updated: May 21, 2026
ID: 000227227
This article provides information about Fatal BUS errors seen with PCI1360 and PCI1318.
Updated: May 21, 2026
ID: 000227163
How to create Cluster Shared Volumes by manually calculating the necessary disk space value.
Updated: May 21, 2026
ID: 000227068
Dell Intel SATA SSD drives may report a not correctly functioning PDR3 event, potentially resulting in a drive failure condition.
Updated: May 21, 2026
ID: 000226989
Dell Open Server Manager (OSM) Health Rollup remains critical status after error or warning condition is remediated.
Updated: May 21, 2026
ID: 000226514
After successful installation of NVIDIA GPU driver on Red Hat Enterprise Linux 9.3, performing nvidia-smi operations may report "no devices found."
Updated: May 20, 2026
ID: 000224586
Dell solid state drive (SSD) fails after system reports low environment operating temperature.
Updated: May 20, 2026
ID: 000224458
Microsoft Hyper-V Virtual Machine (VM) Live Migration may fail or no LUNs are mapped after powering on VMs due to Windows architecture and hardware configuration limiting the number of vFC LUNs.
Updated: May 20, 2026
ID: 000223671
PowerEdge customers using Broadcom NXE adapters in VMware ESXi may experience unexpected results when attempting to tune port parameters. Particularly in configurations with multiple NXE adapters present, understanding the port ordering from both a VMware (vmnicX) and serverPCI-e Slot-Bus-Device-Function (SBDF) may be helpful to select the appropriate commands.
Updated: May 20, 2026
ID: 000223479