This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated: August 31, 2026
ID: 000502480
This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated: August 31, 2026
ID: 000205512
PowerFlex SDSs with Samsung PM1733a NVMe SSDs running firmware 1.0.X or 1.1.X may experience intermittent drive dropouts. Elevated latency and slow I/O on affected drives can trigger cascading timeout failures, including Data Unavailability (DU) events, upgrade failures, and daily operation issues.
Updated: September 04, 2026
ID: 000455462
Powerflex Management server default port 8443 is blocked and the site cannot be reached.
Updated: September 04, 2026
ID: 000215692
When the PowerFlex Manager REST API gateway becomes unavailable, virtual machines running on Nutanix may start becoming inaccessible, resulting in client outages.
Updated: September 04, 2026
ID: 000385318
A single slow SSD device may cause endless rebuilds and eventually a Data Unavailability (DU).
Updated: September 03, 2026
ID: 000387366
The PowerFlex system reports frequent MDM disconnections.
The issue was observed in a PowerFlex Rack 15G cluster in this particular scenario.
Updated: September 03, 2026
ID: 000222235
Dell iDRAC Service Module (dcism) versions earlier than 6.1 contain a defect: when the OS-to-iDRAC pass-through is lost, iSM enters Limited Functionality Mode and retries the connection in an unbounded loop. Every retry runs firewall-cmd --reload twice. The result is thousands of full firewalld reloads per day on the affected node, causing MDM disconnects, SDS decouples, and SCLI login failures.
Updated: September 02, 2026
ID: 000495738
SSL Certificate Verify Failed - Failed to Bootstrap
Updated: September 01, 2026
ID: 000504990
The issue occurs during PowerFlex Manager Platform (PFMP) cluster deployments where the customer security standards do not allow to use of the default UMASK value to 0022 and it is changed to some other value. CMO needs UMASK 022 for the helm charts to be set up.
Updated: August 31, 2026
ID: 000217888
OOM killer (Out Of Memory Killer) was invoked by LIA while generating the getinfo logs causing the SDS service to crash.
Updated: August 31, 2026
ID: 000227538
Resource Group (RG) operations will complete and cause DU when an MDM cluster has fewer virtual IPs than MDM DATA IPs.
Updated: August 31, 2026
ID: 000446482
Resource Group (RG) operations will complete and cause DU when the system has fewer Standby Manager or Tie-Breaker MDMs than expected.
Updated: August 31, 2026
ID: 000446471
Resource Group (RG) operations will complete and cause DU when the system has fewer Standby Manager or Tie-Breaker MDMs than expected.
Updated: August 31, 2026
ID: 000446474
This article lists PowerFlex 5.1 compatibility, showing which VMware, Nutanix, Microsoft Hyper‑V, Citrix and Linux distributions and versions are validated, plus supported storage nodes.
Updated: August 31, 2026
ID: 000502768
Explore the Dell End of Service Life (EOSL) and End of Life (EOL) list for converged infrastructure, storage, and storage networking products. Access End-of-Life documents for hardware, software, and firmware release and service dates
Updated: August 28, 2026
ID: 000185734
This article explains how to reboot different node types for PowerFlex systems.
Updated: August 28, 2026
ID: 000491367
Running command svm status connection is showing both CloudLink nodes as Inaccessible due to blocked port UDP 1194.
Updated: August 27, 2026
ID: 000384973
Use this procedure to verify and upgrade the CPLD firmware version on PowerFlex nodes. PowerFlex Manager does not verify or upgrade CPLD.
Updated: August 27, 2026
ID: 000315068
Dell PM1735a Non-Volatile Memory Express (NVMe) drive failing in PowerEdge servers.
Updated: August 27, 2026
ID: 000481601
This article explains the meaning of Dial Home Symptom code SIO02.04.0000009 and how to troubleshoot it.
Updated: August 27, 2026
ID: 000381561
PowerFlex - After performing network maintenance, the write performance of certain Storage Data Servers (SDS) is degraded.
Updated: August 27, 2026
ID: 000223254
This article details step-by-step procedures to enable suppression of ESXi alarms on TPM when Secure Boot is not enabled on ESXi.
Updated: August 27, 2026
ID: 000312040
This article shows the PowerFlex release matrix, and guidance on how to correlate the various packages.
Updated: August 26, 2026
ID: 000461757
PowerFlex Manager: RKE2 upgrade fails repeatedly due to "405 Not Allowed" error while creating the upgrade payload
During the PowerFlex Management Platform (PFMP) upgrade, the process fails repeatedly, looping at the point of creating the upgrade payload folder in the http-share. The failure occurs with an HTTP 405 Not Allowed error.
Updated: August 26, 2026
ID: 000261179
This article describes a cause for hostd service on ESXi to be non-responsive, and cause the server to become unresponsive to management operations from vCenter. The particular scenarios where this happens is when NFC operations such as backup or replication jobs are performed on disks with an IO filter attached.
Updated: August 26, 2026
ID: 000219067
vSphere ESXi hosts hang and become inaccessible randomly after experiencing high latency within the datastores.
Updated: August 26, 2026
ID: 000203027
Dial home alert is logged when there is a disconnection between SDC multiple SDS.
Updated: August 26, 2026
ID: 000185174
During upgrade of PowerFlex using Installation Manager, unable to upgrade one SDS and unable to mark upgrade complete.
Updated: August 26, 2026
ID: 000167030
There are two options to configure events and alerts:
● Connect directly
● Connect using secure connect gateway
● If you connect directly, only the call home option is available
● If you connect through secure connect gateway, all options through secure connect gateway are enabled
Updated: August 26, 2026
ID: 000324438