Articles
Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*
30 out of 1415 shown
1415 out of 1415 shown
This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated: August 10, 2026
ID: 000205512
This article introduces the VxRail VxVerify tool and how to successfully run VxVerify in a VxRail environment.
Updated: July 31, 2026
ID: 000021527
Event code: VXR508TMP0100
This event code indicates "The system board <name> temperature is less than the lower warning threshold."
Updated: August 13, 2026
ID: 000011746
Software-Defined Data Center (SDDC) Manager precheck failure Multi-Site Service fails due to pantheon service in a failed state.
Service Availability: Check if the service is up and running using command "systemctl status pantheon." As root user, restart the service if required using command "systemctl restart pantheon" from SDDC Manager VM.
Updated: August 13, 2026
ID: 000420702
Event code: VXR508STOR5
This event code indicates "Redundancy lost.<VD/Enclosure Name>"
Updated: August 13, 2026
ID: 000011745
Event code: VXR508RDU0013
This event code indicates "Power supply redundancy is degraded."
Updated: August 13, 2026
ID: 000011744
Event code: VXR508PSU0002
This event code indicates "A predictive failure detected on power supply <number>."
Updated: August 13, 2026
ID: 000011743
Event code: VXR508SWC4004
This event code indicates "A firmware or software incompatibility detected between iDRAC in slot <number> and CMC."
Updated: August 13, 2026
ID: 000011742
Event code: VXR508VLT0302
This event code indicates "CPU <number> <name> voltage is greater than the upper warning threshold."
Updated: August 13, 2026
ID: 000011716
Event code: VXR508VLT0230
This event code indicates "The mezzanine card <number> <name> voltage is less than the lower warning threshold."
Updated: August 13, 2026
ID: 000011715
Event code: VXR508TMPS0100
This event code indicates "Inlet temperature is above warning level for extended duration."
Updated: August 13, 2026
ID: 000011712
Event code: VXR508VDR54
This event code indicates "<VD Name> initialization is terminated."
Updated: August 13, 2026
ID: 000011711
Event code: VXR508PDR211
This event code indicates "<physical disk name> has encountered storage medium error."
Updated: August 13, 2026
ID: 000011710
Event code: VXR508MEM6003
This event code indicates "Memory device status is non-critical. Memory device location: <location>, Possible memory module event cause: <cause>."
Updated: August 13, 2026
ID: 000011709
Event code: VXR508VLT0208
This event code indicates "The memory module <number> <name> voltage is greater than the upper warning threshold."
Updated: August 13, 2026
ID: 000011707
Event code: VXR508VLT0206
This event code indicates "The memory module <number> <name> voltage is less than the lower warning threshold."
Updated: August 13, 2026
ID: 000011706
Event code: VXR508AMP403
This event code indicates "The <sensor name> sensor state has changed to a warning state with a value of <current> A."
Updated: August 12, 2026
ID: 000011705
Event code: VXR508VLT0226
This event code indicates "The memory module <name> voltage is greater than the upper warning threshold."
Updated: August 12, 2026
ID: 000011704
Event code: VXR508VLT0212
This event code indicates "The disk drive bay <name> voltage is less than the lower warning threshold."
Updated: August 12, 2026
ID: 000011703
Event code: VXR508VDR31
This event code indicates "Controller cache is preserved for missing or offline <VD Name>."
Updated: August 12, 2026
ID: 000011701
Event code: VXR508BAT0000
This event code indicates "The system board battery is low."
Updated: August 12, 2026
ID: 000011700
Event code: VXR508TMP1000
This event code indicates "<tempsensor name> exceeded the maximum warning threshold."
Updated: August 12, 2026
ID: 000011699
Event code: VXR508RDU0021
This event code indicates "Unable to determine the redundancy status of the power supply units."
Updated: August 12, 2026
ID: 000011697
When configuring an upstream DNS server for a VxRail cluster through API or VxRail plugin-in UI, and the cluster is using VxRail manager as its internal DNS server, the DNS queries are not forwarded to the designated upstream DNS server.
Updated: August 11, 2026
ID: 000226207
Hosts show a Key Management Service (KMS) warning because attempts to reach the vCenter server on KMIP port 5696 fail; the native provider uses VPXA VPXD ports for trust management, not KMIP.
Updated: August 11, 2026
ID: 000223385
Remediation is available for a vulnerability that could be exploited by malicious users to compromise the affected systems.
Updated: August 11, 2026
ID: 000497857
Event code: VXR508VDR8
This event code indicates "<virtual disk> is degraded either because the physical disk drive in the drive group is removed or the physical disk drive added in a redundant virtual drive has failed."
Updated: August 10, 2026
ID: 000011696
Event code: VXR508FAN0025
This event code indicates "The <sensor name> sensor state has changed to a warning state with a value of <fan speed> RPM."
Updated: August 10, 2026
ID: 000011695
Event code: VXR508TMPS0101
This event code indicates "Inlet temperature is above critical level for extended duration."
Updated: August 10, 2026
ID: 000011693
Event code: VXR508VDR100
This event code indicates "<virtual disk> is unavailable because of incompatibilities with the current controller."
Updated: August 10, 2026
ID: 000011692