Skip to main content
PowerEdge R770AP image

PowerEdge R770AP

PowerEdge R770AP

Articles

Select a category and then a related component to find articles about specific hardware and software.

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 292 shown
292 out of 292 shown

This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server. It is also relevant for 100% fan speeds.
Updated:  February 24, 2026 ID: 000227912

This article details the procedure to troubleshoot power supply unit (PSU) issues that may arise on a PowerEdge Server.
Updated:  February 16, 2026 ID: 000127944

Fans reporting FAN0000/FAN0001 errors (RPM below warning or critical) should be removed and swapped to another connector; if the error follows the fan, replace it.
Updated:  February 20, 2026 ID: 000391086

This article addresses an issue in which conversion of Windows Server from an evaluation to a fully licensed edition fails. The error that is returned appears to indicate a problem with the supplied product key, but the key is known to be valid.
Updated:  February 20, 2026 ID: 000204465

To replace a CMOS battery, remove the air shroud, disconnect and remove any expansion cards, locate the battery socket, and carefully pry out the CMOS battery. After installing a new CMOS battery, you must reinstall the expansion cards, install the air shroud, and restore the BIOS settings, ensuring the battery is operating properly and the correct data and time are set in the System Setup.
Updated:  February 19, 2026 ID: 000234357

PowerEdge connected Dell NVMe SSDs with the Limited Retry (LR) bit set may experience an increase in failures due to elevated media and data‑integrity error rates.
Updated:  February 19, 2026 ID: 000415896

Dell PowerEdge 17G servers added MEMHOT error monitoring in iDRAC10 firmware version 1.20.80.50 combined with supported Field-Programmable Gate Array (FPGA) firmware. Servers configured with Power Supply Cold Redundancy feature enabled can record random SYS565 memory temperature warning events.
Updated:  February 19, 2026 ID: 000388703

vCenter enables Active Directory (AD) and login by Active Directory users have notification "Password will expire in X days," customer must eliminate it.
Updated:  February 16, 2026 ID: 000192597

How to use the PowerEdge Server ePSA tools to stress test the CPU.
Updated:  February 16, 2026 ID: 000289909

This article provides information about how to use the LCC to deploy a supported OS.
Updated:  February 13, 2026 ID: 000334676

Dell Micron 7450 and 7500 Non-Volatile Memory Express solid state drives may encounter drive initialization failure due to a firmware issue, resulting in the solid state drives being unrecoverable.
Updated:  February 13, 2026 ID: 000368482

Dell PowerEdge Server remediation is available for Intel® Server Firmware Vulnerability that could be exploited by malicious users to compromise the affected systems.
Updated:  February 11, 2026 ID: 000426775

Dell PowerEdge Server remediation is available for 2026.1 Intel Platform Update (IPU) components that could be exploited by malicious users to compromise the affected systems.
Updated:  February 11, 2026 ID: 000426748

Dell PowerEdge Server remediation is available for 2026.1 Intel Platform Update (IPU) components that could be exploited by malicious users to compromise the affected systems.
Updated:  February 11, 2026 ID: 000426743

Dell PowerEdge Server remediation is available for 2025.4 Intel Platform Update (IPU) components that could be exploited by malicious users to compromise the affected systems.
Updated:  February 11, 2026 ID: 000426734

The PowerEdge embedded LifeCycle Controller provides a simplified method for installation of supported Windows Server and Linux server operating systems with the OS Deployment feature. This article explains how to use the iDRAC LifeCycle Controller to install a supported operating system on most Dell PowerEdge servers. Step-by-step instructions and OS installation videos for Windows Server, Ubuntu Server LTS, SUSE Linux Enterprise Server, or Red Hat Enterprise Linux installation with LifeCycle Controller
Updated:  February 10, 2026 ID: 000130160

This article provides a high‑level guide to downloading vendor‑specific firmware and drivers for common PowerEdge NICs such as NVIDIA, Broadcom, and Intel. These processes complement Dell Update Packages (DUPs) and are used when vendor‑specific firmware or drivers are required beyond Dell’s updates.
Updated:  February 09, 2026 ID: 000423756

This is the start-up page for a new Dell PowerEdge Server with an Integrated Dell Remote Access Controller (iDRAC). The article details system installation, use of the iDRAC, LifeCycle Controller (LCC) configuration, and installing an operating system.
Updated:  February 06, 2026 ID: 000123958

Dell Samsung PM893 SSDs with Firmware HJ55 or Earlier Experience Premature SMART Failures
Updated:  February 06, 2026 ID: 000333265

Reports show NVLink failures on an R760XA with NVIDIA H100NVL GPUs and bridges, with 12 of 18 links active; standby links are incorrectly flagged as down due to a issue in DCGM versions up to 3.1.3.1.
Updated:  February 06, 2026 ID: 000420594

The information below covers the steps involved in installing SLES 15 OS in Dell EMC PowerEdge Servers using HTTP Boot.
Updated:  January 30, 2026 ID: 000138011

NVIDIA adapters (ConnectX NICs and DPUs) running firmware version xx.46.1006 may encounter NC‑SI communication failures, resulting in incorrect device reporting and visibility issues within management tools such as iDRAC and Redfish.
Updated:  January 30, 2026 ID: 000399996

Dell PowerEdge servers with common design components are grouped into generations, for example PowerEdge 17th generation servers, 16th generation, 15th generation, or 14th generation. This article provides general guidance for PowerEdge server model naming convention to identify the generation and common components. This article also lists all PowerEdge servers by model including type, CPU, generation, and remote management components.
Updated:  January 29, 2026 ID: 000137343

On Dell PowerEdge 17G servers equipped with factory installed industry standard ConnectX 6 Dx cards, applying the Mellanox ConnectX 6 Dx firmware update from within the operating system may fail to detect all adapters. This can result in incomplete firmware updates in multi card configurations. This limitation does not apply to OEM Dell branded cards.
Updated:  January 28, 2026 ID: 000415145

Information about servicing and troubleshooting issues in your Dell PowerEdge Rack and Tower servers' hardware and System Management tools
Updated:  January 28, 2026 ID: 000203864

R7725, R6725, R7715, and R6715 the number of CPU Cores is not recognized correctly.
Updated:  January 27, 2026 ID: 000321587

Dell Intel SATA SSD drives may report a not correctly functioning PDR3 event, potentially resulting in a drive failure condition.
Updated:  January 26, 2026 ID: 000226989

Understand and troubleshoot PowerEdge hard disk drives, RAID, PowerEdge RAID Controller, and other storage hardware such as cables, backplane, so forth.
Updated:  January 26, 2026 ID: 000110444

Dell PowerEdge servers do not support operating system installation, or boot from direct CPU‑attached NVMe SSD drives if the metadata format size is not set to 0.
Updated:  January 26, 2026 ID: 000417881

Explore various RAID levels - RAID 0, 1, 5, 6, and 10 - implemented in Dell PowerEdge servers. Learn about their configurations, benefits, and how they impact data redundancy and performance.
Updated:  January 23, 2026 ID: 000128635