Correctable and uncorrectable memory errors on PowerEdge Server with DDR4 and changes to troubleshooting steps
Updated: September 11, 2026
ID: 000053203
Information about how Troubleshooting and Diagnose PowerEdge servers and CPU issues.
Updated: September 10, 2026
ID: 000179752
Legacy Summit drives with Product Part ID (PPID) revision A03 or earlier run SxS9 firmware and can be upgraded to SxSA, but the upgrade is not recommended because SxSA is intended for drives with the updated preamp hardware; drives with PPID revision A04 or later must use SxSA or later and downgrading is unsupported.
Updated: September 18, 2026
ID: 000502414
Toshiba AL15SE HDDs may enter a Drive Not Ready (DNR) state and report repeated seek retries associated with sense codes 04-4C-91, 04-4C-95, 04-4C-E0, or 04-44-82.
Updated: September 18, 2026
ID: 000495316
This document highlights minimum, recommended, and latest code versions for Dell Technologies PowerEdge products. We carefully evaluate and monitor code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated: September 15, 2026
ID: 000227230
The iDRAC provides a web interface and a command-line interface that allows administrators to perform remote management tasks.
Updated: September 14, 2026
ID: 000179517
Dell iDRAC9 and iDRAC10 remediations for an OpenSSH security vulnerability that could be exploited by malicious users to compromise the affected system.
Updated: September 14, 2026
ID: 000509006
Hardware Diagnostics are embedded tools installed in the pre-OPERATING SYSTEM of your server to check hardware is working as designed.
Updated: September 14, 2026
ID: 000132726
Dell OpenManage Enterprise (OME) uses a multi-step process to discover and onboard servers through iDRAC. The discovery process begins with a basic network reachability check (ICMP ping) followed by protocol-level communication (Redfish or WS-Man). If any step in this chain fails, the discovery will not succeed.
Updated: September 14, 2026
ID: 000507806
This article identifies which Operating System (OS) files the iDRAC Service Module (iSM) replicates the Lifecycle Controller (LC) logs to.
Updated: September 10, 2026
ID: 000064204
This article provides information about how to create a bootable USB drive from and OS ISO file for manual installation.
Updated: September 10, 2026
ID: 000334285
The Dell Nautilus Firmware Update Utility is flexible and simple to use as it contains all the latest, relevant firmware updates for hard drives in your Dell server.
Updated: September 10, 2026
ID: 000141811
Dell OS and Applications Solutions on Dell TechCenter - Project Sputnik, Microsoft Windows, Red Hat Linux, SUSE, Ubuntu, and more
Updated: September 10, 2026
ID: 000145895
In the HPC world today, an introduction to AMD’s latest generation EPYC processor code-named Rome.
Updated: September 10, 2026
ID: 000137696
How to Identify the physical slot number in iDRAC based off the device name in vSphere/VSAN.
Updated: September 09, 2026
ID: 000179543
This blog discusses the performance of CONVERGE, a computational Fluid Dynamics (CFD) application from Convergent Science on the Dell Ready Solution for HPC Digital Manufacturing with AMD EPYC™ 7002 series processors.
Updated: September 09, 2026
ID: 000137286
Firmware updates using the iDRAC or LifeCycle Controller does not work on any Emulex 8 Gb fiber channel adapter.
Updated: September 09, 2026
ID: 000144615
This article describes how to reenable the Lifecycle Controller (LCC) when it goes into recovery mode.
Updated: September 09, 2026
ID: 000136186
Micron 5x00 Series SSDs may experience read/write performance degradation after reaching approximately 65,535 power-on hours (POH), which equates to roughly 7.5 years of operation. This issue affects performance only and does not result in data loss or drive failure.
Updated: September 09, 2026
ID: 000464492
This article provides information about how to update your system's firmware from the Lifecycle Controller on Dell servers.
Updated: September 09, 2026
ID: 000128133
Dell PowerEdge Server remediation is available for Nuvoton NPCT7xx Trusted Platform Module (TPM) 2.0 firmware versions that could be exploited by malicious users to compromise the affected system.
Updated: September 08, 2026
ID: 000477639
Dell PowerEdge Server remediation is available for Nuvoton NPCT7xx Trusted Platform Module (TPM) 2.0 firmware versions that could be exploited by malicious users to compromise the affected system.
Updated: September 08, 2026
ID: 000502288
This article shows How To determine why a virtual machine powered off or rebooted by reviewing log files and host details to identify guest shutdowns, user or API requests, HA resets or system faults.
Updated: September 07, 2026
ID: 000205778
This article explains how to perform a driver or firmware update directly from the operating system (OS) using a Dell Update Packages (DUP).
Updated: September 04, 2026
ID: 000130467
Dell iDRAC9 and iDRAC10 remediations for a Command Injection security vulnerability that could be exploited by malicious users to compromise the affected system.
Updated: September 03, 2026
ID: 000504998
If the LifeCycle Controller (LCC) is enabled but it is missing in the menu during the POST, it is possible that you must import the iDRAC license to enable it again.
Updated: September 03, 2026
ID: 000205309
This article explains how to find supported memory configuration for your PowerEdge server.
Updated: September 02, 2026
ID: 000135681
There are special considerations for GPU firmware updates outlined in this article.
Updated: September 02, 2026
ID: 000291566
To replace a CMOS battery, remove the air shroud, disconnect and remove any expansion cards, locate the battery socket, and carefully pry out the CMOS battery. After installing a new CMOS battery, you must reinstall the expansion cards, install the air shroud, and restore the BIOS settings, ensuring the battery is operating properly and the correct data and time are set in the System Setup.
Updated: September 02, 2026
ID: 000234357
This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server.
It is also relevant for 100% fan speeds.
Updated: September 02, 2026