Skip to main content
PowerEdge R750xs image

PowerEdge R750xs

PowerEdge R750xs

Articles

Select a category and then a related component to find articles about specific hardware and software.

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 704 shown
704 out of 704 shown

The article describes how to troubleshoot network connectivity issues for network cards.
Updated:  May 21, 2026 ID: 000227983

This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server. It is also relevant for 100% fan speeds.
Updated:  May 21, 2026 ID: 000227912

Seagate Skybolt and SkyboltServoBP drive fails with medium format corrupted errors.
Updated:  May 21, 2026 ID: 000227930

After installing the Windows Server 2022 Software RAID driver during installation, the Micron 7500 drive does not immediately appear. Wait approximately 20-30 s and press the Refresh button more than once for it to become visible.
Updated:  May 21, 2026 ID: 000227822

Connection Status shows disconnected for all devices in OpenManage Enterprise Services (OMES) plugin 4.1.0 under the Site Health tab - Managed Devices page.
Updated:  May 21, 2026 ID: 000227514

Multiple SKHynix NVMe (PS1010) drives in the same server experienced PCIe link training failures during the deployment phase, resulting in the drives entering read-only mode.
Updated:  May 21, 2026 ID: 000227423

Dell has introduced significant updates to how PowerEdge servers manage coin-cell (CMOS) battery functionality and related event logging. Beginning with 14th Generation (14G) servers in August 2024 — through iDRAC and BIOS firmware updates — and extending to 15G and 16G platforms from February 2025 onward, several key changes have been implemented
Updated:  May 21, 2026 ID: 000227413

Viewing the VLAN details of a deployment template's network settings list devices that are not associated to the template.
Updated:  May 21, 2026 ID: 000227227

This article provides information about Fatal BUS errors seen with PCI1360 and PCI1318.
Updated:  May 21, 2026 ID: 000227163

How to create Cluster Shared Volumes by manually calculating the necessary disk space value.
Updated:  May 21, 2026 ID: 000227068

Dell Intel SATA SSD drives may report a not correctly functioning PDR3 event, potentially resulting in a drive failure condition.
Updated:  May 21, 2026 ID: 000226989

This is a new attribute that is seen in Server Configuration Profile exports. This attribute cannot be edited.
Updated:  May 21, 2026 ID: 000226963

This is seen when using direct attached storage with an Emulex LPe35002-M2-D and Red Hat Enterprise Linux, the server fails to boot.
Updated:  May 21, 2026 ID: 000226962

Intel Chipset Driver Build '477GN' failed to upgrade from Build 'VGX10' on 15G System Models with Windows Defender Application (WDAC) in Enforced Mode.
Updated:  May 21, 2026 ID: 000226451

This article describes how to view and clear the system event log (SEL) in System Setup.
Updated:  May 21, 2026 ID: 000226396

A UEFI0074 warning is generated in the life cycle Log during Windows installation or after running Windows Update. Microsoft Windows operating systems can update the database and DBX entries to ensure that the platform is up to date per industry security standards.
Updated:  May 21, 2026 ID: 000226358

This article describes how to find the iDRAC's current MAC address.
Updated:  May 21, 2026 ID: 000226214

PowerEdge 14/15G servers cannot downgrade to iDRAC9 firmware versions 4.40.10.00 and older once the iDRAC9 has installed the June 2024 firmware release.
Updated:  May 21, 2026 ID: 000225924

Observing frequent nmlx5_en_L2TableIndexAdd/Remove events generated by the Mellanox nmlx5 driver in the ESXi VMkernel log.
Updated:  May 21, 2026 ID: 000225826

During the power counter roll-over for utilization, the power counter rolls over before the rollover counter. This leads to an erroneous power spike which may throttle the server.
Updated:  May 21, 2026 ID: 000225350

This is a firmware catalog which contains validated and certified firmware stack for selected Dell VMware vSAN Ready Nodes based on Dell customized ESXi 8.X branch Images.
Updated:  May 21, 2026 ID: 000225254

This is a firmware catalog which contains validated and certified firmware stack for selected Dell VMware vSAN Ready Nodes based on Dell customized ESXi 7.x branch Images.
Updated:  May 21, 2026 ID: 000225253

Initiating a graceful restart or shutdown using Redfish APIs may fail for the Windows Server Operating System.
Updated:  May 21, 2026 ID: 000224986

When Dell Intel E810-CQDA2 part number 85F8F or DWNRF is used with FR1 transceiver part number PJ62G, it cannot link up. The maximum power consumption of the transceiver Dell Part Number (DPN) PJ62G is 4W, which exceeds the NIC device's power supply limit of 3.5W.
Updated:  May 21, 2026 ID: 000224793

Dell solid state drive (SSD) fails after system reports low environment operating temperature.
Updated:  May 20, 2026 ID: 000224458

This article provides information about PERC ECC messages that are seen due to firmware memory handling issues.
Updated:  May 20, 2026 ID: 000223832

PERC H750, H755, and H755N controllers may experience single or multi-bit ECC messages.
Updated:  May 20, 2026 ID: 000223831

Microsoft Hyper-V Virtual Machine (VM) Live Migration may fail or no LUNs are mapped after powering on VMs due to Windows architecture and hardware configuration limiting the number of vFC LUNs.
Updated:  May 20, 2026 ID: 000223671

PowerEdge customers using Broadcom NXE adapters in VMware ESXi may experience unexpected results when attempting to tune port parameters. Particularly in configurations with multiple NXE adapters present, understanding the port ordering from both a VMware (vmnicX) and serverPCI-e Slot-Bus-Device-Function (SBDF) may be helpful to select the appropriate commands.
Updated:  May 20, 2026 ID: 000223479

Dell PowerEdge server with a Broadcom BCM57414 PCIe adapter could encounter intermittent network-disconnected problem in a VMware NSX-T environment.
Updated:  May 20, 2026 ID: 000223469