All products: Contaminants such as dust on fiber optic connector end face causes poor IO performance
Dust or chemical contamination at the endface of a fiber optic LC connector or transceiver module impedes signaling. Dell engineering teams have verified cases in which a fully functional port appears to be a bad port because dirty optical connectors manifest as a port failing loop testing with acceptable power measurement levels. Cable connectors should be cleaned and when stored must be protected from dust particle or chemical contamination.
Updated: March 23, 2026
ID: 000246018
This article details the procedure to troubleshoot power supply unit (PSU) issues that may arise on a PowerEdge Server.
Updated: March 16, 2026
ID: 000127944
After BIOS update on a 17G system, the Max Speed field in the System Management BIOS (SMBIOS) differs from the Central Processing Unit (CPU) spec because it reports capability, not turbo rating.
Updated: March 24, 2026
ID: 000443098
Dell PowerEdge servers with common design components are grouped into generations, for example PowerEdge 17th generation servers, 16th generation, 15th generation, or 14th generation. This article provides general guidance for PowerEdge server model naming convention to identify the generation and common components. This article also lists all PowerEdge servers by model including type, CPU, generation, and remote management components.
Updated: March 23, 2026
ID: 000137343
The BIOS processor settings on 17G PowerEdge servers do not have the option to disable virtualization technology.
Updated: March 23, 2026
ID: 000379653
R7725, R6725, R7715, and R6715 the number of CPU Cores is not recognized correctly.
Updated: March 23, 2026
ID: 000321587
This article provides a high‑level guide to downloading vendor‑specific firmware and drivers for common PowerEdge NICs such as NVIDIA, Broadcom, and Intel.
These processes complement Dell Update Packages (DUPs) and are used when vendor‑specific firmware or drivers are required beyond Dell’s updates.
Updated: March 18, 2026
ID: 000423756
PowerEdge 14G, 15G, 16G, and 17G servers skip Preboot eXecution Environment (PXE) boot when an "Unavailable" entry is last in the boot order.
Updated: March 18, 2026
ID: 000396285
Dell PowerEdge 17G servers record inaccurate CPU index within iDRAC10 life cycle Log (LCLOG) and System event log (SEL) when machine check event (MCE) is recorded.
Updated: March 18, 2026
ID: 000382576
Dell PowerEdge 17G Intel servers may record memory module temperature warning events in the Lifecycle Log and System Event Log during the server cold boot sequence.
Updated: March 18, 2026
ID: 000381690
Settings are not saved in UEFI Boot Settings if more than one setting is changed.
Updated: March 18, 2026
ID: 000366899
Dell iDRAC9 and iDRAC10 remediations are available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.
Updated: March 17, 2026
ID: 000434533
Dell PowerEdge Toshiba MG08 and MG09 hard drives may encounter uninterruptible Background Media Scanning (BMS), causing I/O errors, or timeouts.
Updated: March 17, 2026
ID: 000381662
Dell Micron 7450 and 7500 Non-Volatile Memory Express solid state drives may encounter drive initialization failure due to a firmware issue, resulting in the solid state drives being unrecoverable.
Updated: March 17, 2026
ID: 000368482
This article provides information about Intermittent High Fan Speeds on Dell 17G PowerEdge Servers with NVIDIA ConnectX-6 OCP Cards installed.
Updated: March 16, 2026
ID: 000334522
Dell PowerEdge Server remediation is available for a Tianocore EDK2 Vulnerability that could be exploited by malicious users to compromise the affected systems.
Updated: March 16, 2026
ID: 000440351
This article explains iDRAC and BIOS settings that disable or limit iDRAC Direct functionality
Updated: March 16, 2026
ID: 000434735
Seagate Skybolt and SkyboltServoBP drive fails with medium format corrupted errors.
Updated: March 13, 2026
ID: 000227930
On Dell PowerEdge 17G servers using Broadcom 5719 QP OCP NX1 cards (DPN M2PYY), firmware installation fails when Secure Boot is enabled on SUSE Linux Enterprise Server (SLES).
Additionally, the installed firmware version is not detected by the Operating System (OS). Disabling Secure Boot allows the firmware to install and be detected correctly.
Updated: March 11, 2026
ID: 000388249
Dell PowerEdge Server remediation is available for 2025.3 Intel Platform Update (IPU) components that could be exploited by malicious users to compromise the affected systems.
Updated: March 10, 2026
ID: 000364913
This article explains how to address the error "The system has found a problem on your machine and cannot continue. Unable to restore the system configuration. A security violation was detected". Purple screen / Purple screen of Death (PSOD)
Updated: March 09, 2026
ID: 000436068
This article outlines the actions required to prepare a system for retirement or repurposing using the LifeCycle controller.
Updated: March 09, 2026
ID: 000198190
Understand and troubleshoot PowerEdge hard disk drives, RAID, PowerEdge RAID Controller, and other storage hardware such as cables, backplane, so forth.
Updated: March 09, 2026
ID: 000110444
This article provides PowerEdge server troubleshooting for No Power, No POST, No Boot and No Video issues. This includes blade, rack, and tower servers.
Updated: March 06, 2026
ID: 000152161
This is the latest version of the Dell OpenManage Enteprise 4.0 Support Matrix.
Updated: March 06, 2026
ID: 000216821
This article provides an explanation of the backplane hard drive LED indicators.
Updated: March 05, 2026
ID: 000413096
PowerEdge servers do not support operating system installation, or boot from direct CPU‑attached NVMe SSD drives if the metadata format size is not set to 0.
Updated: March 05, 2026
ID: 000417881
NVIDIA adapters (ConnectX NICs and DPUs) running firmware version xx.46.1006 may encounter NC‑SI communication failures, resulting in incorrect device reporting and visibility issues within management tools such as iDRAC and Redfish.
Updated: March 05, 2026
ID: 000399996
PowerEdge servers equipped with Dell Micron 7500 NVMe solid state drives may exhibit elevated fan RPM speeds.
Updated: March 04, 2026
ID: 000350914
Dell Enterprise NVMe solid state drives may be leveraged as a substitute for Dell Data Center NVMe solid state drives.
Updated: March 04, 2026
ID: 000315161