Skip to main content
OEMR R360 image

OEMR R360

OEMR R360

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 177 shown
177 out of 177 shown

This article provides information about how to verify if a Network Interface Card (NIC) is compatible with a PowerEdge Server.
Updated:  May 23, 2026 ID: 000349619

This article provides information about CPU Machine Check errors and common causes and proper handling when errors are seen.
Updated:  May 23, 2026 ID: 000349127

Dell Micron 7450 and 7500 Non-Volatile Memory Express solid state drives may encounter drive initialization failure due to a firmware issue, resulting in the solid state drives being unrecoverable.
Updated:  May 23, 2026 ID: 000368482

Unsure about the procedure to update a specific component's firmware in a PowerEdge system? Learn how to in this specific article.
Updated:  May 23, 2026 ID: 000333712

R7725, R6725, R7715, and R6715 the number of CPU Cores is not recognized correctly.
Updated:  May 23, 2026 ID: 000321587

Dell Technologies advises against downgrading Hard Drive or SSD firmware, except in validated scenarios, due to unpredictable results and version reporting issues.
Updated:  May 23, 2026 ID: 000311902

The "Predictive failure reported for disk x" error continues to be logged every 24 hours, even after the identified drive has been replaced. The issue only affects drives connected to PERC Controllers in RAID configuration.
Updated:  May 23, 2026 ID: 000308774

During Windows Server 2025 installation by iDRAC virtual media, a disk with size 0 B is displayed on the drive selection page.
Updated:  May 22, 2026 ID: 000278171

PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
Updated:  May 22, 2026 ID: 000256907

CPUs can be perceived to be hot while server is idle.
Updated:  May 22, 2026 ID: 000250878

The Dell SS540 SAS solid state drive is reported as not correctly functioning.
Updated:  May 21, 2026 ID: 000237298

PowerEdge: Broadcom NXE devices with Driver 229.2.73 (SWB: Y7T4X) may report that the interfaces are missing in the operating system when secure boot is enabled.
Updated:  May 21, 2026 ID: 000236776

An "HWC1110" event was reported during the iDRAC Firmware update.
Updated:  May 21, 2026 ID: 000228298

This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server. It is also relevant for 100% fan speeds.
Updated:  May 21, 2026 ID: 000227912

PowerEdge T360, R360, R260, T160: CPU turbo boost cannot reach the theoretical max frequency.
Updated:  May 21, 2026 ID: 000226634

This article describes how to view and clear the system event log (SEL) in System Setup.
Updated:  May 21, 2026 ID: 000226396

This article describes how to find the iDRAC's current MAC address.
Updated:  May 21, 2026 ID: 000226214

Dell solid state drive (SSD) fails after system reports low environment operating temperature.
Updated:  May 20, 2026 ID: 000224458

PowerEdge R360 and T360 default iDRAC license is incorrect.
Updated:  May 20, 2026 ID: 000223542

Dell Intel E810-C adapters do not support disabling the Virtual Machine Device Queue (VMDQ) loopback feature using "Intnetcli" tool.
Updated:  May 20, 2026 ID: 000223462

Dell Samsung Serial Attached SCSI (SAS) PM1653 and PM1655 solid state drives may report excessive Sense Key faults 0x3, 0x11, 0x0, or 0x4, 0x29, 0x4. These faults have the potential to cause unexpected drive issues.
Updated:  May 20, 2026 ID: 000222201

Dell Enterprise SAS, SATA SSD: SMART predictive failures triggered by remaining write endurance falling below the threshold
Updated:  May 19, 2026 ID: 000221846

In some migration scenarios, the OpenManage Enterprise 4.0 target import operation may fail with an error 'Failed to decrypt backup archive' during migration. Use the following article to help in troubleshooting this scenario and various ways to address the failure.
Updated:  May 19, 2026 ID: 000221490

Network port enumeration on Windows Server 2022 with Dell network adapters may swap port designations.
Updated:  May 19, 2026 ID: 000221408

If the Life Cycle (LC) language is set to a non-English language, the system stops responding on the 'Loading BIOS Drivers' screen.
Updated:  May 19, 2026 ID: 000221245

After an update to 7.00.00.00 or higher, the iDRAC9 web server may become inaccessible where the user has uploaded a custom or CA signed web certificate.
Updated:  May 19, 2026 ID: 000220891

The iDRAC is unable to connect to a Server Message Block (SMB) share when the optional "SMB3 share encryption" is enabled.
Updated:  May 19, 2026 ID: 000219260

BIOS/CPLD or backplane firmware DUP may fail to update when attempted soon after iDRAC restart.
Updated:  May 18, 2026 ID: 000216521

This article describes what can happen while collecting SupportAssist logs using iDRAC9 UI. The operation may result in an error, or incomplete logs may be collected.
Updated:  May 17, 2026 ID: 000211904

BIOS, CPLD, Backplane, PSU, or few other firmware update on Red Hat Enterprise Linux (RHEL) 9 may report failure when update attempted using Dell Update Package (DUP).
Updated:  May 16, 2026 ID: 000208958