Skip to main content

VxRail Software

VxRail Software

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 1367 shown
1367 out of 1367 shown

The dockr_ver health check found that running docker images are not up to date with expected versions or missing.
Updated:  May 11, 2026 ID: 000189813

Guide to resolve disk and power supply shown as N/A with VxRail 7.0.x Physical View.
Updated:  May 10, 2026 ID: 000189161

Support new iDRAC events monitor: SEKM075. Event VXR508SEKM075 iDRAC is unable to switch from Local Key Management (iLKM) to Secure Enterprise Key Manager (SEKM)
Updated:  May 11, 2026 ID: 000190286

iDRAC Service Module (iSM) versions 4.0.1 and earlier for VMware ESXi may stop functioning and the dcism service stop if the core hostd service of the ESXi host was recently restarted.
Updated:  May 11, 2026 ID: 000190265

The intent of this KB is to provide the proper course of action to take in the event that the notified mystic code takes place.
Updated:  May 11, 2026 ID: 000189612

Error shown in iDRAC virtual console "LIC501: A required license is missing or expired."
Updated:  May 11, 2026 ID: 000189590

VxRail 7.0.130 or 4.7.525 or later graceful reboot and power on not completed successfully, vSAN cluster loses vSAN tag on VMkernel.
Updated:  May 10, 2026 ID: 000189539

This article details how to confirm the build version of various VxRail components. This includes ESXi, vCenter Server Appliance, and VxRail Manager.
Updated:  May 10, 2026 ID: 000189488

Event code: VXR508MEM0802 - DIMM degradation detected
Updated:  May 10, 2026 ID: 000189457

One or more VxRail Manager checks returns an event code 1 or 2, representing yellow or red alerts, respectively. These must be investigated before conducting cluster activities (for example node expansion or upgrade).
Updated:  May 10, 2026 ID: 000189003

On VxRail, false NIC100 and NIC101 events may be logged in Lifecycle Controller logs with Intel X710 family of adapters running firmware (FW) v19.5.12.
Updated:  May 10, 2026 ID: 000188812

One or more VxRail Manager health-checks returns event code 1 or 2, representing yellow or red alerts, respectively. These must be investigated prior to upgrading the cluster.
Updated:  May 10, 2026 ID: 000187739

This article outlines the response from VxRail Engineering to the security issue described in VMware Security Advisory VMSA-2021-0010 and recommendations to fix or mitigate the issue.
Updated:  May 10, 2026 ID: 000187489

Do not Remove disks during vSAN resync as it can result in a Data Loss.
Updated:  May 09, 2026 ID: 000186364

If clusters have shared witness configured, the vSAN disk format must be upgraded manually after all clusters and witness hosts get upgraded.
Updated:  May 09, 2026 ID: 000186100

This article describes an issue where an initial configuration or first run of VxRail may fail when using an External vCenter 7.0 Update 2.
Updated:  May 09, 2026 ID: 000185996

This article provides a video and troubleshooting options for iDRAC connectivity issues.
Updated:  May 09, 2026 ID: 000185547

LCM from 4.7.x to 7.0.132 failed at extracting the upgrade bundle, progress ended at 10%.
Updated:  May 09, 2026 ID: 000185222

The "Write" Endurance of solid state drive (SSD) arg1 is less than the threshold value of Remaining Write Rated Endurance.
Updated:  May 09, 2026 ID: 000184532

Network connectivity issues in ESXi with 25G or above bandwidth NICs when jumbo MTU: 9000 is enabled.
Updated:  May 08, 2026 ID: 000184342

Event code: VXR500PST0142 This event code indicates "MRC fatal error."
Updated:  May 08, 2026 ID: 000013497

Event code: VXR500PST0140 This event code indicates "System management interrupt initialization failed."
Updated:  May 08, 2026 ID: 000013495

Event code: VXR500PST0195 This event code indicates "CPU configuration failed."
Updated:  May 08, 2026 ID: 000013493

Event code: VXR500PST0194 This event code indicates "Remote access controller configuration failed."
Updated:  May 08, 2026 ID: 000013490

Event code: VXR500PCI5005 This event code indicates "An auxiliary power fault issue is detected in the PCIe adapter that was turned on in PCIe slot<slot number>."
Updated:  May 08, 2026 ID: 000013489

Event code: VXR500PCI3016 This event code indicates "Device option ROM on mezzanine card failed to support Link Tuning or FlexAddress."
Updated:  May 08, 2026 ID: 000013488

Event code: VXR500PDR29 This event code indicates "Rebuild on <PD Name> completed with error(s)."
Updated:  May 08, 2026 ID: 000013487

Event code: VXR500PCI5004 This event code indicates "A power fault issue is detected in the PCIe adapter that was turned on in PCIe slot<slot number>."
Updated:  May 08, 2026 ID: 000013485

Event code: VXR500PDR61 This event code indicates "The rebuild of <physical disk> failed due to errors on the source physical disk."
Updated:  May 08, 2026 ID: 000013484

Event code: VXR500PST0256 This event code indicates "POST fatal error detected."
Updated:  May 08, 2026 ID: 000013483