691 out of 691 shown

Dell Unity software reports error in Unisphere when an internal SSD is fully worn; however, there are no reported Alerts or dial home errors.
Updated:  May 19, 2026 ID: 000189150

Unity 5.3 Seahawk brings some significant changes to the Unity product that will affect every customer. In the Seahawk release, the online drive firmware upgrade is periodically run on a physical Unity system to upgrade outdated drives.
Updated:  May 19, 2026 ID: 000218180

This document describes the objects and equipment used by Customer Engineers (CEs) when on-site. Please check and prepare in advance.
Updated:  May 20, 2026 ID: 000224128

This KB describes one of the causes of SupportAssist configuration failures.
Updated:  May 20, 2026 ID: 000223354

Newly added users are unable to access share in a multiprotocol file system.
Updated:  May 20, 2026 ID: 000223045

This KB explains how to manage VNX's unisphere using an LDAP user
Updated:  May 20, 2026 ID: 000019503

The Pre-Upgrade Health Check (PUHC) script fails. The tar reports 'This does not look like a tar archive' and header errors, caused by the browser incorrectly decompressing the tar.gz file.
Updated:  May 20, 2026 ID: 000052568

This KB describes one of the causes of the 0x900a008 error when creating an NFS share.
Updated:  May 20, 2026 ID: 000221956

Is LLDP supported on a Dell Unity array?
Updated:  May 19, 2026 ID: 000221910

This article discusses whether Unity is susceptible to CVE-2026-20833.
Updated:  May 19, 2026 ID: 000466883

When a system drive fails in a traditional pool, a hotspare is used to copy customer data luns. Once the system drive is replaced, the system drive does not become available as a hotspare. This could lead to a hotspare rule failure as there is one less hotspare available.
Updated:  May 19, 2026 ID: 000203123

When we cancel a pool expansion job using UEMCLI, the storage reports that the action was completed successfully although the operation continues in the background. This behavior is corrected in OE 5.1.
Updated:  May 19, 2026 ID: 000220002

Under certain out-of-space conditions, an upgrade to 5.1 may trigger file system offline or rolling SP reboots.
Updated:  May 19, 2026 ID: 000191205

When performing a Pre-Upgrade Health Check (PUHC) on Unity OE 5.1 or later code, it may report an error: dm::check_if_user_root_fs_has_enough_space_1
Updated:  May 19, 2026 ID: 000219186

After upgrading Unity some administrative issues regarding the VMFS datastore can be noticed. 1. Failure or partial failure adding or removing datastore access to ESXi hosts through Unisphere. 2. From vCenter, it is not possible to see datastore name changes made from Unisphere.
Updated:  May 19, 2026 ID: 000217696

Customers receiving daily alerts that their support contract is about to expire even after renewing the support contract. (Dell Correctable)
Updated:  May 19, 2026 ID: 000217685

Unisphere event log, SNMP, and remote syslog are not updated.
Updated:  May 19, 2026 ID: 000217629

This article discusses the method to get the file fullname path when you have the version 8.3 shortname path.
Updated:  May 18, 2026 ID: 000216879

Unity system dials home with a neo14:601f5 error.
Updated:  May 18, 2026 ID: 000216877

Unity arrays running 5.3.0.0.5.120 code with SupportAssist enabled may experience an SP panic after being up for approximately 2 months with a two SCG configuration or after approximately 4 months with a single SCG configuration, or direct connect.
Updated:  May 18, 2026 ID: 000216765

When uploading text files to Unity's FTP server, file formatting may become invalid due to the difference between Windows and Unix/Linux end-of-line (EOL) characters. Windows uses two characters, CR+LF while Unix/Linux only uses LF. By default, Unity's FTP server uses ASCII transfer mode and since Unity uses a Unix/Linux base, all EOL characters are converted to LF. This makes files appear to be broken when read from a Windows client. To avoid this behavior, files should be uploaded using bin transfer mode. This makes sure the file is transferred "as is" with no changes. This may also be helpful when transferring image, audio and video files as they also require binary mode to avoid corruption.
Updated:  May 18, 2026 ID: 000216708

It has been observed that some Solid-State Drive (SSD) models may have their End-of-Life (EOL) flag set after accumulating a total power-on time of approximately 6.8 years or more. This flag indicates that the drive has reached the end of its expected lifespan and may no longer be supported or guaranteed to function reliably.
Updated:  May 18, 2026 ID: 000216667

SPCv controller can hang in PHY_STOP (Physical Layer Stop) command with IOs. This can cause the SPCv controller to crash causing SP panic.
Updated:  May 18, 2026 ID: 000216606

Unisphere GUI and CLI via SSH are no longer accessible after attempting to change DNS settings. Restarting management services does not resolve the issue. It was also determined that ECOM does not start on either SP or stay running for more than 10 minutes.
Updated:  May 18, 2026 ID: 000216591

This KB describes one of the causes of the Unknown status of Replication.
Updated:  May 18, 2026 ID: 000216468

This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Datacenter Infrastructure products. We carefully evaluate and monitor code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated:  May 18, 2026 ID: 000205512

This article describes one of the causes of the 0x1000100 error that results from the uemcli command.
Updated:  May 18, 2026 ID: 000216071

Red Had Enterprise Linux client was unable to mount Unity NAS Server NFS Share. Receiving error NFS4ERR_MINOR_VERS_MISMATCH.
Updated:  May 18, 2026 ID: 000216055

Some IDs such as Fake, nobody, c4, log, nogroup, admin, service, ECOM etc were found while scanning the Unity Array.
Updated:  May 18, 2026 ID: 000215739

A system is either having its Management IP address configured during deployment or having the management IP address subnet changed. When a gateway is chosen, if the Subnet ID is used the Management IP configuration fails. This can occur either within Unisphere or at the command line. An error is seen about a failure to change the management IP configuration in Unisphere and also at the command line. Both Unisphere and the command line will be unable to be logged into. Access from ipmitool on either SP must be used to continue and resolve the issue.