Articles
Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*
30 out of 960 shown
960 out of 960 shown
This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Datacenter Infrastructure products. We carefully evaluate and monitor code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated: April 27, 2026
ID: 000205512
This article is an accumulation of questions, answers, and information relating to VxRail upgrades.
Updated: April 21, 2026
ID: 000020129
Event code VXR508STOR373 is triggered due to a hot spare drive not supporting unmap when the virtual drive (VD) has it enabled.
Updated: May 01, 2026
ID: 000189232
This KB article briefly discusses Event code: VXR500FAN0016
Updated: May 01, 2026
ID: 000011651
Event Code VXR508STOR372 triggers due to unmap being disabled or not supported on the controller.
Updated: May 01, 2026
ID: 000189231
Event Code VXR508STOR371 indicates: Unable to use the physical drive arg1 because the drive selected is not unmap-capable for virtual drive configuration.
Updated: May 01, 2026
ID: 000189229
Event code: VXR500FAN0020
This event code indicates "The <fan name> is non-functional."
Updated: April 30, 2026
ID: 000011654
Event code: VXR500ENC23
This event code indicates "<enclosure name> - Issue with PHY <PHY data>."
Updated: April 30, 2026
ID: 000011653
Event code: VXR500AMP405
This event code indicates "The <sensor name> sensor state has changed to a failed state with a value of <current> A."
Updated: April 30, 2026
ID: 000011650
Event code: VXR500ENC3
This event code indicates "<Enclosure Name> is shutdown."
Updated: April 30, 2026
ID: 000011649
Event code: VXR500FAN8503
This event code indicates "The Chassis was turned off because more than two internal fans stopped functioning."
Updated: April 30, 2026
ID: 000011648
Event code: VXR500CBL0002
This event code indicates "Backplane <bay ID> signal cable disconnected."
Updated: April 30, 2026
ID: 000011647
Event code: VXR500CBL0006
This event code indicates "Unsupported backplane <bay ID> configuration: Multiple RAID controllers cannot be connected to the same backplane."
Updated: April 30, 2026
ID: 000011644
Event code: VXR500CBL0005
This event code indicates "Backplane <bay ID> <connector name> connector incorrectly connected to the motherboard SATA controller."
Updated: April 30, 2026
ID: 000011642
Event code: VXR500FAN0015
This event code indicates "<fan name> RPM is greater than the upper critical threshold."
Updated: April 30, 2026
ID: 000011641
VxRail: Event Code: VXR500ENC24
This event code indicates "Communication with <enclosure name> is intermittent."
Updated: April 30, 2026
ID: 000011639
Event code: VXR500CBL0007
This event code indicates "Backplane <bay ID> <cable name> cable and backplane <bay ID> <cable name> cable are swapped."
Updated: April 30, 2026
ID: 000011638
Event code: VXR500CBL8500
This event code indicates "SAS cable <cable id> to expander <expander id> is not connected."
Updated: April 30, 2026
ID: 000011637
Event code: VXR500CBL0001
This event code indicates "Backplane <bay ID> power cable disconnected."
Updated: April 30, 2026
ID: 000011625
VxRail: Event Code: VXR500ENC100
This event code indicates "<enclosure name> is sending inconsistent responses to the controller."
Updated: April 30, 2026
ID: 000011624
Event code: VXR500FAN0022
This event code indicates "The <sensor name> sensor has failed, and the last recorded value by the sensor was <fan speed> RPM."
Updated: April 30, 2026
ID: 000011622
Node expansion fails due to issues in the VxRail RADAR engine.
Updated: April 30, 2026
ID: 000222754
This document is an accumulation of questions, answers, and information relating to VCF on VxRail upgrades with RPS.
Updated: April 30, 2026
ID: 000021470
Event code: VXR500IOV118
This event code indicates "Fabric <fabric ID> is down."
Updated: April 30, 2026
ID: 000011592
Event code: VXR500ENC2
This event code indicates "<Enclosure Management Module Name> was removed."
Updated: April 29, 2026
ID: 000011617
Event code: VXR500IOV2008
This event code indicates "The Chassis Management Controller (CMC) is unable to communicate with the PCIe subsystem."
Updated: April 29, 2026
ID: 000011611
Event code: VXR500LNK0001
This event code indicates "Network share name unavailable."
Updated: April 29, 2026
ID: 000011609
Event code: VXR500IOV111
This event code indicates "Unable to update Chassis Infrastructure firmware."
Updated: April 29, 2026
ID: 000011608
Event code: VXR500NIC017
This event code indicates "Unable to delete vFlash pending one-time boot configuration"
Updated: April 29, 2026
ID: 000011601
Event code: VXR500LNK0004
This event code indicates "Unable to connect to FTP server."
Updated: April 29, 2026
ID: 000011596