Skip to main content
Connectrix B-Series Hardware image

Connectrix B-Series Hardware

Connectrix B-Series Hardware

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 252 shown
252 out of 252 shown

This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Datacenter Infrastructure products. We carefully evaluate and monitor code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated:  December 22, 2025 ID: 000205512

This KB provides steps to rename a zone object. You can use these steps for all zone object types, including cfgs, zones, and aliases.
Updated:  October 29, 2025 ID: 000217021

While configuring the Brocade switch for tacacs+ user authentication. User is then pointing to a tacacs+ server application called tacacs.net. User authentication passes but user is unable to run any commands.
Updated:  January 07, 2026 ID: 000022769

Connectrix B-Series and MDS-Series: How to check the link connectivity between a host and storage on SAN switches.
Updated:  December 12, 2025 ID: 000019070

Rx Power value of the SFP is less than 200
Updated:  December 11, 2025 ID: 000064661

Supportsave fails with "Error occurred in SSH."
Updated:  December 04, 2025 ID: 000361107

HOW TO configure the MAPS.
Updated:  December 04, 2025 ID: 000023159

How to get a rough indication of the severity of the delay of frames transmitted on an FC port and ISL trunk.
Updated:  December 03, 2025 ID: 000022822

Connectrix B-Series: SNMP management tool cannot communicate with the Brocade switch.
Updated:  November 27, 2025 ID: 000057282

DCX and DCX-4S directors and FC8-32E and FC8-48E Condor3 based 8G port blades.
Updated:  November 21, 2025 ID: 000009750

Cause for duplicate ACKs seen in the FCIP statistics.
Updated:  November 21, 2025 ID: 000022749

Flow monitors are configured to count the Initiator or Target (IT) flows to a device. Because of zoning and device activity, the number of flows has surpassed the threshold for the PIDs for which the alerts were triggered.
Updated:  November 21, 2025 ID: 000050147

What is a keepalive timeout in FCIP?
Updated:  November 21, 2025 ID: 000064015

Use the SHA512 authentication protocol instead of deprecated MD5 and SHA to resolve the SNMPv3 warning on Connectrix B-Series switches running FOS 9.2.x.
Updated:  November 21, 2025 ID: 000309272

Learn how the MyService360 services analytics dashboard integrates the Dell AIOps (formerly CloudIQ) Health Score into the Install Base views. This integration streamlines services and product health management by IT admins using the MyService360 and Dell AIOps portals. Verify supported products by portal and access helpful Dell AIOps resources.
Updated:  November 13, 2025 ID: 000206380

This article covers when a user is trying to add ISL to a long-distance enabled trunk that has VC init enabled.
Updated:  November 10, 2025 ID: 000018912

Procedures on how to Replace an SFP Transceiver for All Connectrix Brocade B-Series
Updated:  October 30, 2025 ID: 000021333

How to recover a password on a switch with Fabric OS v9.1.0 or later.
Updated:  October 29, 2025 ID: 000219204

The command output for sfpshow displays invalid output for online ports as "Cannot read Serial Data!" or "Does not use an SFP or is disabled" for online ports.
Updated:  October 29, 2025 ID: 000065649

Ports on MOD_Val
Updated:  October 28, 2025 ID: 000327719

Connectrix ED-DCX8510-8B: How to upgrade a replacement CP that is arrived with lower firmware version of other CP in the DCX 8510 directors.
Updated:  October 22, 2025 ID: 000022848

Connectrix B-Series: How to troubleshoot switch unreachable issues.
Updated:  October 22, 2025 ID: 000050346

Connectrix: Why does the port not come online after replacing faulty hardware that caused the port to enter a Port_Flt state?
Updated:  October 20, 2025 ID: 000065039

Using the measured light power levels displayed in the sfpshow (Brocade) and the show interface transceiver details (Cisco) to identify physical layer issues with switch to switch (ISL) and node to switch connections.
Updated:  October 07, 2025 ID: 000028053

SSH private/public key authentication fails.
Updated:  October 07, 2025 ID: 000064822

Continuous Link Reset events when you connect QLE266X HBA to the Brocade 16 Gb switch.
Updated:  September 23, 2025 ID: 000056338

Dell Connectrix (Brocade) remediation is available for an EZswitch vulnerability in Brocade Fabric OS (FOS) software that may be exploited by malicious users to compromise the affected system.
Updated:  September 18, 2025 ID: 000205092

Dell EMC Connectrix B-Series remediation is available for multiple security vulnerabilities that may be exploited by malicious users to compromise the affected system.
Updated:  September 18, 2025 ID: 000189972

Dell Connectrix (Brocade) remediation is available for multiple Fabric OS (FOS) security vulnerabilities that may be exploited by malicious users to compromise the affected system.
Updated:  September 18, 2025 ID: 000203396