Skip to main content
PowerEdge R260 image

PowerEdge R260

PowerEdge R260

Articles

Select a category and then a related component to find articles about specific hardware and software.

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 559 shown
559 out of 559 shown

This article provides a step-by-step guide on how to remove and install a cooling fan on a Dell system. These instructions are applicable to both standard and high-performance fans. The guide covers the removal and installation of the cooling fan assembly.
Updated:  May 21, 2026 ID: 000234366

This article describes the different type of controllers and the ways in which they should be reseated.
Updated:  May 21, 2026 ID: 000228521

Seagate Summit SAS/SATA drives report medium errors or sense key 3/11 on PowerEdge and PowerVault systems due to a firmware issue causing weak writes to a drive sector.
Updated:  May 21, 2026 ID: 000239838

The BIOS setting changes may not appear in iDRAC if configured using the F11 Boot Manager on Dell PowerEdge 16G and 17G platforms.
Updated:  May 21, 2026 ID: 000238951

The Dell SS540 SAS solid state drive is reported as not correctly functioning.
Updated:  May 21, 2026 ID: 000237298

PowerEdge: Broadcom NXE devices with Driver 229.2.73 (SWB: Y7T4X) may report that the interfaces are missing in the operating system when secure boot is enabled.
Updated:  May 21, 2026 ID: 000236776

In some instances, the firmware update job may fail to initiate when performing a firmware update through available iDRAC interfaces.
Updated:  May 21, 2026 ID: 000234480

In Windows Server 2025, when leveraging CPUs with more than 256 cores, the Broadcom BCM5720 fails to retrieve a DHCP address, leading to no network connectivity.
Updated:  May 21, 2026 ID: 000233949

OpenManage Enterprise integration for VMware vCenter may fail to Unmanage hosts with error "UNMANAGE_REMOVE_MEL_FAILURE"
Updated:  May 21, 2026 ID: 000233873

When a PS1010 or PS1030 NVMe SSD is installed, a PSOD may occur during production or gathering Operating System (OS) logs.
Updated:  May 21, 2026 ID: 000228837

Warning messages regarding "icen_SetRxQueueFilter" and "Failed to add cloud filter" in ESXi 8 VMware VMkernel log.
Updated:  May 21, 2026 ID: 000228397

An "HWC1110" event was reported during the iDRAC Firmware update.
Updated:  May 21, 2026 ID: 000228298

The front hard drive slots 4 and 5 have a nonfunctional HDD4/HDD5 slot label with a 4x2.5 ChipSATA configuration.
Updated:  May 21, 2026 ID: 000228297

The article describes how to troubleshoot network connectivity issues for network cards.
Updated:  May 21, 2026 ID: 000227983

Seagate Skybolt and SkyboltServoBP drive fails with medium format corrupted errors.
Updated:  May 21, 2026 ID: 000227930

This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server. It is also relevant for 100% fan speeds.
Updated:  May 21, 2026 ID: 000227912

Dell has introduced significant updates to how PowerEdge servers manage coin-cell (CMOS) battery functionality and related event logging. Beginning with 14th Generation (14G) servers in August 2024 — through iDRAC and BIOS firmware updates — and extending to 15G and 16G platforms from February 2025 onward, several key changes have been implemented
Updated:  May 21, 2026 ID: 000227413

This article provides information about Fatal BUS errors seen with PCI1360 and PCI1318.
Updated:  May 21, 2026 ID: 000227163

How to create Cluster Shared Volumes by manually calculating the necessary disk space value.
Updated:  May 21, 2026 ID: 000227068

Dell Intel SATA SSD drives may report a not correctly functioning PDR3 event, potentially resulting in a drive failure condition.
Updated:  May 21, 2026 ID: 000226989

PowerEdge T360, R360, R260, T160: CPU turbo boost cannot reach the theoretical max frequency.
Updated:  May 21, 2026 ID: 000226634

This article describes how to view and clear the system event log (SEL) in System Setup.
Updated:  May 21, 2026 ID: 000226396

This article describes how to find the iDRAC's current MAC address.
Updated:  May 21, 2026 ID: 000226214

Updating 16G PowerEdge Server BIOS may result in Secure Boot database updates.
Updated:  May 21, 2026 ID: 000226055

The PowerEdge 16G 700 W Power supply, Dell Part Number (DPN): 3D09N, only supports high line voltage, the input voltage range is 200 V AC-240 V AC.
Updated:  May 21, 2026 ID: 000225989

Initiating a graceful restart or shutdown using Redfish APIs may fail for the Windows Server Operating System.
Updated:  May 21, 2026 ID: 000224986

Dell solid state drive (SSD) fails after system reports low environment operating temperature.
Updated:  May 20, 2026 ID: 000224458

Microsoft Hyper-V Virtual Machine (VM) Live Migration may fail or no LUNs are mapped after powering on VMs due to Windows architecture and hardware configuration limiting the number of vFC LUNs.
Updated:  May 20, 2026 ID: 000223671

PowerEdge server intermittently encounters a UEFI iSCSI Boot From SAN (BFS) fatal error 8 upon booting with the PowerStore appliance.
Updated:  May 20, 2026 ID: 000223454

VMware vCenter registration may fail in OMEVV 1.3 with a custom certificate chain installed in OpenManage Enterprise (OME) or vCenter.
Updated:  May 20, 2026 ID: 000223404