Skip to main content
PowerEdge R960 image

PowerEdge R960

PowerEdge R960

Articles

Select a category and then a related component to find articles about specific hardware and software.

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 674 shown
674 out of 674 shown

The article describes how to troubleshoot network connectivity issues for network cards.
Updated:  May 21, 2026 ID: 000227983

This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server. It is also relevant for 100% fan speeds.
Updated:  May 21, 2026 ID: 000227912

OpenManage Enterprise version 4.1 entitlements feature will no longer work after October 2024 due to the decommissioning of legacy OAUTH APIs. Also, the standalone Dell License Manager application is end-of-life.
Updated:  May 21, 2026 ID: 000228401

Warning messages regarding "icen_SetRxQueueFilter" and "Failed to add cloud filter" in ESXi 8 VMware VMkernel log.
Updated:  May 21, 2026 ID: 000228397

NVIDIA Mellanox OpenFabrics Enterprise Distribution (OFED) 23.10-0.5.5.0 driver package does not show Red Hat Linux 9.3 as a supported Operating System (OS) version.
Updated:  May 21, 2026 ID: 000228364

When editing a deployment template the 'Edit Components' screen is stuck with the 'Loading' animation. Also, when editing a compliance template the 'Template Details' screen is blank.
Updated:  May 21, 2026 ID: 000228133

Seagate Skybolt and SkyboltServoBP drive fails with medium format corrupted errors.
Updated:  May 21, 2026 ID: 000227930

After installing the Windows Server 2022 Software RAID driver during installation, the Micron 7500 drive does not immediately appear. Wait approximately 20-30 s and press the Refresh button more than once for it to become visible.
Updated:  May 21, 2026 ID: 000227822

The "Memory Mapped I/O Base" option is not available in the BIOS Setup under 'Integrated Devices' on Dell 16G servers.
Updated:  May 21, 2026 ID: 000227626

Connection Status shows disconnected for all devices in OpenManage Enterprise Services (OMES) plugin 4.1.0 under the Site Health tab - Managed Devices page.
Updated:  May 21, 2026 ID: 000227514

Dell has introduced significant updates to how PowerEdge servers manage coin-cell (CMOS) battery functionality and related event logging. Beginning with 14th Generation (14G) servers in August 2024 — through iDRAC and BIOS firmware updates — and extending to 15G and 16G platforms from February 2025 onward, several key changes have been implemented
Updated:  May 21, 2026 ID: 000227413

Viewing the VLAN details of a deployment template's network settings list devices that are not associated to the template.
Updated:  May 21, 2026 ID: 000227227

This article provides information about Fatal BUS errors seen with PCI1360 and PCI1318.
Updated:  May 21, 2026 ID: 000227163

How to create Cluster Shared Volumes by manually calculating the necessary disk space value.
Updated:  May 21, 2026 ID: 000227068

Dell Intel SATA SSD drives may report a not correctly functioning PDR3 event, potentially resulting in a drive failure condition.
Updated:  May 21, 2026 ID: 000226989

PowerEdge 16G platform is stuck in an endless loop, continuously restarting during the POST at the "configure memory…" stage.
Updated:  May 21, 2026 ID: 000226735

Prerequisites of enabling Intel Trust Domain Extension (TDX) on Dell 16G Intel PowerEdge servers
Updated:  May 21, 2026 ID: 000226452

This article describes how to view and clear the system event log (SEL) in System Setup.
Updated:  May 21, 2026 ID: 000226396

A UEFI0074 warning is generated in the life cycle Log during Windows installation or after running Windows Update. Microsoft Windows operating systems can update the database and DBX entries to ensure that the platform is up to date per industry security standards.
Updated:  May 21, 2026 ID: 000226358

This article talks about the PERC H965 controller's supported virtual disk stripe sizes.
Updated:  May 21, 2026 ID: 000226265

This article describes how to find the iDRAC's current MAC address.
Updated:  May 21, 2026 ID: 000226214

Updating 16G PowerEdge Server BIOS may result in Secure Boot database updates.
Updated:  May 21, 2026 ID: 000226055

Initiating a graceful restart or shutdown using Redfish APIs may fail for the Windows Server Operating System.
Updated:  May 21, 2026 ID: 000224986

The server fails to power on after a system crash is encountered and LifeCycle Log (LC Log) records a watchdog event from iDRAC.
Updated:  May 21, 2026 ID: 000224883

Dell solid state drive (SSD) fails after system reports low environment operating temperature.
Updated:  May 20, 2026 ID: 000224458

This article provides information about PERC ECC messages that are seen due to firmware memory handling issues.
Updated:  May 20, 2026 ID: 000223832

PERC H750, H755, and H755N controllers may experience single or multi-bit ECC messages.
Updated:  May 20, 2026 ID: 000223831

Microsoft Hyper-V Virtual Machine (VM) Live Migration may fail or no LUNs are mapped after powering on VMs due to Windows architecture and hardware configuration limiting the number of vFC LUNs.
Updated:  May 20, 2026 ID: 000223671

The issue is cosmetic. There is no functional impact. The lspci -v command requires certain labels to read. Labels are missing from the current Basic Input Output System (BIOS) but are added to June block BIOS v2.2.4.
Updated:  May 20, 2026 ID: 000223577

PowerEdge customers using Broadcom NXE adapters in VMware ESXi may experience unexpected results when attempting to tune port parameters. Particularly in configurations with multiple NXE adapters present, understanding the port ordering from both a VMware (vmnicX) and serverPCI-e Slot-Bus-Device-Function (SBDF) may be helpful to select the appropriate commands.
Updated:  May 20, 2026 ID: 000223479