This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated:  June 17, 2026 ID: 000205512

Missing PSNT serial number on nodes that shipped with VxRail version 7.0.450 or 8.0.100 cause issues with VxRail cluster creation or node expansion operations.
Updated:  May 19, 2026 ID: 000218616

VXR0140A1 alarm triggers when vSAN (vSAN) cluster storage space exceeds configured thresholds (vSAN 7.0 Update 2 onward). Check and reduce vSAN datastore usage per VMware KB 71003.
Updated:  June 17, 2026 ID: 000182229

Event code: VXR508RDU0003 This event code indicates "Fan redundancy is degraded."
Updated:  June 17, 2026 ID: 000011727

Event code: VXR508TMP0108 This event code indicates "The memory module <number> temperature is greater than the upper warning threshold."
Updated:  June 17, 2026 ID: 000011726

Event code: VXR508PWR1007 This event code indicates "The system performance degraded because power exceeds capacity."
Updated:  June 17, 2026 ID: 000011725

Event code: VXR508PDR69 This event code indicates "Rebuild not possible on <physical disk>."
Updated:  June 17, 2026 ID: 000011724

Event code: VXR508PDR75 This event code indicates "Copyback stopped for hot spare <physical disk> ."
Updated:  June 17, 2026 ID: 000011723

Failed to upload LCM bundle if the cluster has vLCM enabled and the VxRail Manager TLS certificate is not signed by VMCA.
Updated:  June 17, 2026 ID: 000202110

Error shown in iDRAC virtual console "LIC501: A required license is missing or expired."
Updated:  June 17, 2026 ID: 000189590

Node expansion stuck for hours, no progress, and no errors, due to the workflow encountered unexpected interruption.
Updated:  June 17, 2026 ID: 000225019

Expansion satellite node failed if the cluster is using VxRail manager internal Domain Name System (DNS), and node management traffic cidr is different between the new satellite node and existing nodes.
Updated:  June 17, 2026 ID: 000212788

VxRail cluster upgrade or node expansion failed at host setting M2M switch
Updated:  June 17, 2026 ID: 000206115

This KB article describes Event VXR034020 Remote connectivity lost.
Updated:  June 16, 2026 ID: 000194170

Event VXR034018 failed to enable remote connectivity.
Updated:  June 16, 2026 ID: 000193409

This KB article briefly discusses VxRail Event code: VXR508STOR0106
Updated:  June 16, 2026 ID: 000011410

Event code: VXR508STOR044 This event code indicates "All physical disks specified are not part of the same disk group."
Updated:  June 16, 2026 ID: 000011412

Event code: VXR508STOR040 This event code indicates "Invalid AttributeName <attribute name>."
Updated:  June 16, 2026 ID: 000011411

Event code: VXR508RFL2006 This event code indicates "Internal Dual SD Module <name> is write protected."
Updated:  June 16, 2026 ID: 000011409

Health-check returns an event indicating that VxVerify found vCenter Server Appliance (VCSA) 'storage' or 'storage-database' Application Programming Interface (API) check are not in status 'green'.
Updated:  June 16, 2026 ID: 000205760

Dell VxRail remediation is available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.
Updated:  June 16, 2026 ID: 000477957

Explore the Dell End of Service Life (EOSL) and End of Life (EOL) list for converged infrastructure, storage, and storage networking products. Access End-of-Life documents for hardware, software, and firmware release and service dates
Updated:  June 15, 2026 ID: 000185734

The Health-check returns an event indicating that VxVerify found a mismatch in the Network Time Protocol (NTP) settings.
Updated:  June 15, 2026 ID: 000204889

Health-check returns an event indicating that VxVerify found an issue with the vCenter VMware Certificate Authority (VMCA) mode.
Updated:  June 15, 2026 ID: 000204891

Health-check returns an event indicating that VxVerify found an issue with vCenters Fully Qualified Domain Name (FQDN) in VxRail Manager configuration set.
Updated:  June 15, 2026 ID: 000204892

On August 20, 2021, Dell Technologies announced the Next-Generation consolidated connectivity solution availability for Secure Connect Gateway 5.0 (servers, networking, data storage, data protection, hyperconverged and converged systems). It provides customers with a single solution for managing their entire Dell environment in the data center.
Updated:  June 12, 2026 ID: 000209853

HWC8010 or HWC8011 UEFI Errors in POST for iDRAC Hardware configuration validation typically occurs due to firmware updates, and the addition or removal of hardware components. It is recommended to review logs and investigate any recent changes before applying this solution.
Updated:  June 12, 2026 ID: 000464066

Temporarily enabling DRS to allow hands-off upgrade
Updated:  June 12, 2026 ID: 000020705

Event code: VXR508STOR0105 This event code indicates "No enclosures are displayed."
Updated:  June 11, 2026 ID: 000011408

Event code: VXR508STOR028 This event code indicates "Virtual disk not found."