문서
잘못된 입력입니다. 문자, 숫자 및 <>)(%/;,=#-/*을(를) 제외한 특수 문자만 사용하십시오.
30/188 표시
188/188 표시
이 문서에서는 가상 디스크에 디스크를 추가하거나 가상 디스크를 재구성하는 방법을 보여줍니다.
업데이트됨: 6월 02, 2026
ID: 000116592
이 문서에서는 DSU(Dell System Update)에 대한 지침을 제공합니다.
업데이트됨: 6월 01, 2026
ID: 000130590
This article provides guidance for Dell PowerEdge servers requiring remediation for the Microsoft Secure Boot certificate expiration (June 2026).
It applies to UEFI-based systems with Secure Boot enabled and older Secure Boot certificates affected by the Microsoft Secure Boot certificate expiration (June 2026). The operating system primarily manages Secure Boot certificate updates, and customers should ensure they update their systems using supported Microsoft update mechanisms.
It applies to Windows Server operating systems affected by this change, as defined by Microsoft, running on physical systems with customer-managed firmware and Secure Boot configuration.
It does not apply to cloud platforms or appliances where the provider manages firmware and Secure Boot keys, such as Microsoft Azure, AX, or APEX-Managed Cloud.
Systems already running BIOS versions that include the updated Secure Boot certificates may not require this procedure.
업데이트됨: 6월 04, 2026
ID: 000402373
This article explains what disk errors PDR1001 and PDR3 mean on Dell PowerEdge servers and the best practices to resolve these issues. By understanding these alerts and acting promptly, you can maintain storage health, prevent downtime, and protect critical data.
업데이트됨: 6월 02, 2026
ID: 000143247
How to Identify the physical slot number in iDRAC based off the device name in vSphere/VSAN.
업데이트됨: 6월 01, 2026
ID: 000179543
This document answers questions about SupportAssist Enterprise.
업데이트됨: 6월 01, 2026
ID: 000060848
이 문서에서는 Dell PowerEdge PERC12(H965) 및 최신 컨트롤러를 사용할 때 4Kn 엔드투엔드(E2E) 스토리지가 포함된 VMware ESXi 9 가상 머신을 배포하기 위한 요구 사항을 설명합니다. 또한 ESXi가 진정한 4Kn E2E 대신 4Kn SWE(Software Emulation)를 사용하는 경우를 식별하는 방법과 E2E를 방지하는 조건에 대해서도 설명합니다.
업데이트됨: 5월 29, 2026
ID: 000467282
This article explains how to create and import an iDRAC certificate.
업데이트됨: 5월 28, 2026
ID: 000120158
During Windows Server 2025 installation by iDRAC virtual media, a disk with size 0 B is displayed on the drive selection page.
업데이트됨: 5월 26, 2026
ID: 000278171
아래 문서는 iDRAC의 일부 버전에 대한 중요한 로그 항목 "하드웨어 오류 상태로 인해 전면 LED 패널에 액세스할 수 없는 SWC5008"에서 PowerEdge 시스템을 복구하는 해결 방법입니다.
업데이트됨: 5월 25, 2026
ID: 000205597
This article provides steps to troubleshoot a chassis intrusion, chassis open message for PowerEdge servers.
업데이트됨: 5월 25, 2026
ID: 000136481
PowerEdge servers do not support operating system installation, or boot from direct CPU‑attached NVMe SSD drives if the metadata format size is not set to 0.
업데이트됨: 5월 24, 2026
ID: 000417881
PowerEdge connected Dell NVMe SSDs with the Limited Retry (LR) bit set may experience an increase in failures due to elevated media and data‑integrity error rates.
업데이트됨: 5월 24, 2026
ID: 000415896
Dell PowerEdge Toshiba MG08 and MG09 hard drives may encounter uninterruptible Background Media Scanning (BMS), causing I/O errors, or timeouts.
업데이트됨: 5월 24, 2026
ID: 000381662
Dell Micron 7450 and 7500 Non-Volatile Memory Express solid state drives may encounter drive initialization failure due to a firmware issue, resulting in the solid state drives being unrecoverable.
업데이트됨: 5월 23, 2026
ID: 000368482
This article provides information about how to verify if a Network Interface Card (NIC) is compatible with a PowerEdge Server.
업데이트됨: 5월 23, 2026
ID: 000349619
This article provides information about CPU Machine Check errors and common causes and proper handling when errors are seen.
업데이트됨: 5월 23, 2026
ID: 000349127
Unsure about the procedure to update a specific component's firmware in a PowerEdge system? Learn how to in this specific article.
업데이트됨: 5월 23, 2026
ID: 000333712
R7725, R6725, R7715 및 R6715의 CPU 코어 수가 올바르게 인식되지 않습니다.
업데이트됨: 5월 23, 2026
ID: 000321587
Dell Enterprise NVMe solid state drives may be leveraged as a substitute for Dell Data Center NVMe solid state drives.
업데이트됨: 5월 23, 2026
ID: 000315161
Dell Technologies advises against downgrading Hard Drive or SSD firmware, except in validated scenarios, due to unpredictable results and version reporting issues.
업데이트됨: 5월 23, 2026
ID: 000311902
Some Dell PowerEdge 16th Generation (16G) servers may exhibit a 0V reading for Central Processing Unit (CPU) Voltage Regulator sensors within the Integrated Dell Remote Access Controller 9 (iDRAC9) user interfaces.
업데이트됨: 5월 23, 2026
ID: 000309893
The "Predictive failure reported for disk x" error continues to be logged every 24 hours, even after the identified drive has been replaced. The issue only affects drives connected to PERC Controllers in RAID configuration.
업데이트됨: 5월 23, 2026
ID: 000308774
PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
업데이트됨: 5월 22, 2026
ID: 000256907
CPUs can be perceived to be hot while server is idle.
업데이트됨: 5월 22, 2026
ID: 000250878
The HBA355i with Seagate 8 TB SAS hard drive fails to boot to Windows Server 2022 after a cold boot.
업데이트됨: 5월 22, 2026
ID: 000245194
The Dell SS540 SAS solid state drive is reported as not correctly functioning.
업데이트됨: 5월 21, 2026
ID: 000237298
PowerEdge: Broadcom NXE devices with Driver 229.2.73 (SWB: Y7T4X) may report that the interfaces are missing in the operating system when secure boot is enabled.
업데이트됨: 5월 21, 2026
ID: 000236776
This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server.
It is also relevant for 100% fan speeds.
업데이트됨: 5월 21, 2026
ID: 000227912
Multiple SKHynix NVMe (PS1010) drives in the same server experienced PCIe link training failures during the deployment phase, resulting in the drives entering read-only mode.
업데이트됨: 5월 21, 2026
ID: 000227423