문서
Tooltip title
특정 하드웨어 및 소프트웨어에 대한 자료를 찾으려면 범주를 선택한 다음 관련 구성 요소를 선택합니다.
잘못된 입력입니다. 문자, 숫자 및 <>)(%/;,=#-/*을(를) 제외한 특수 문자만 사용하십시오.
30/722 표시
722/722 표시
이 문서에서는 IDRAC 라이선스를 가져올 때 표시되는 LIC008 오류에 대한 정보를 제공합니다.
업데이트됨: 5월 23, 2026
ID: 000353269
이 문서에서는 NIC(Network Interface Card)가 PowerEdge 서버와 호환되는지 확인하는 방법에 대한 정보를 제공합니다.
업데이트됨: 5월 23, 2026
ID: 000349619
NVIDIA has updated the signing certificate for its UEFI network driver from Microsoft UEFI CA 2011 to Microsoft UEFI CA 2023. PowerEdge 17G platforms already trust the CA 2023 certificate, but 15G/16G and earlier servers require a BIOS update released in December 2025. Systems without this updated certificate support may fail to initialize the NIC UEFI driver when Secure Boot is enabled.
업데이트됨: 5월 24, 2026
ID: 000420051
PowerEdge servers do not support operating system installation, or boot from direct CPU‑attached NVMe SSD drives if the metadata format size is not set to 0.
업데이트됨: 5월 24, 2026
ID: 000417881
PowerEdge connected Dell NVMe SSDs with the Limited Retry (LR) bit set may experience an increase in failures due to elevated media and data‑integrity error rates.
업데이트됨: 5월 24, 2026
ID: 000415896
Server BIOS Update Guidelines for Microsoft Secure Boot Certificates are provided in this article.
업데이트됨: 5월 24, 2026
ID: 000402373
PowerEdge 14G, 15G, 16G, and 17G servers skip Preboot eXecution Environment (PXE) boot when an "Unavailable" entry is last in the boot order.
업데이트됨: 5월 24, 2026
ID: 000396285
FAN0000/FAN0001 오류(경고 미만의 RPM 또는 위험)를 보고하는 팬은 제거한 후 다른 커넥터로 교체해야 합니다. 팬에서 오류가 발생하면 팬을 교체합니다.
업데이트됨: 5월 24, 2026
ID: 000391086
Dell PowerEdge Toshiba MG08 and MG09 hard drives may encounter uninterruptible Background Media Scanning (BMS), causing I/O errors, or timeouts.
업데이트됨: 5월 24, 2026
ID: 000381662
Encountering PR8 errors in the LifeCycle (LC) log when using a BlueField-3 (BF3) Data Processing Units (DPU) card (DPN: HFWRM).
업데이트됨: 5월 24, 2026
ID: 000379421
Dell Chicony power supply (X1HXF) reports an Under Voltage Fault event PSU0034.
업데이트됨: 5월 23, 2026
ID: 000353410
This article provides information about CPU Machine Check errors and common causes and proper handling when errors are seen.
업데이트됨: 5월 23, 2026
ID: 000349127
Unsure about the procedure to update a specific component's firmware in a PowerEdge system? Learn how to in this specific article.
업데이트됨: 5월 23, 2026
ID: 000333712
Dell Samsung PM893 SSDs with Firmware HJ55 or Earlier Experience Premature SMART Failures
업데이트됨: 5월 23, 2026
ID: 000333265
New deployments of OpenManage Enterprise 4.4.0 are experiencing service failures after configuring the time zone for GMT +02:00 Helsinki, Kyiv, Riga, Sofia, Tallinn, Vilnius. The issue is only seen on fresh deployment of OpenManage Enterprise (OME) 4.4.0 on Hyper-V. Deploying OpenManage Enterprise (OME) on other hypervisors is not impacted.
업데이트됨: 5월 23, 2026
ID: 000326459
R7725, R6725, R7715 및 R6715의 CPU 코어 수가 올바르게 인식되지 않습니다.
업데이트됨: 5월 23, 2026
ID: 000321587
PowerEdge: 2.5" 15k RPM SAS 하드 드라이브의 산업 종료 생산에 대한 Dell 서비스 지원
업데이트됨: 5월 23, 2026
ID: 000314166
Dell Technologies advises against downgrading Hard Drive or SSD firmware, except in validated scenarios, due to unpredictable results and version reporting issues.
업데이트됨: 5월 23, 2026
ID: 000311902
The "Predictive failure reported for disk x" error continues to be logged every 24 hours, even after the identified drive has been replaced. The issue only affects drives connected to PERC Controllers in RAID configuration.
업데이트됨: 5월 23, 2026
ID: 000308774
이벤트 후 PowerEdge 15G 서버가 응답하지 않거나 응답을 중지PST0210.
업데이트됨: 5월 22, 2026
ID: 000297851
During Windows Server 2025 installation by iDRAC virtual media, a disk with size 0 B is displayed on the drive selection page.
업데이트됨: 5월 22, 2026
ID: 000278171
Leveraging the 'Reboot Required' filter and selecting all items in this filtered view results in the 'make compliant' job applying all non-compliant firmware components. An unexpected reboot of the target is seen as components that do require a restart are deployed to the target. The issue is only seen if selecting all objects and using the 'Reboot Required' filter. All other filters work as designed.
업데이트됨: 5월 22, 2026
ID: 000270340
Performing a "yum update" check for Red Hat Enterprise Linux or SuSE Linux for Enterprise Servers updates may fail due to improper iDRAC RPM in the Dell YUM repository on linux.dell.com.
업데이트됨: 5월 22, 2026
ID: 000262378
PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
업데이트됨: 5월 22, 2026
ID: 000256907
DSU and SUU may not inventory any server components due to a crash caused in the invcol.exe module. Inventory Collector 24.09 and newer is no longer fully compatible with Windows Server 2016.
업데이트됨: 5월 22, 2026
ID: 000251806
CPUs can be perceived to be hot while server is idle.
업데이트됨: 5월 22, 2026
ID: 000250878
Various Dell enterprise products behave unexpectedly if IPMI is intentionally disabled from communicating between the operating system and iDRAC. This can be done by disabling the "In-band Management Interface" setting in BIOS System Security settings.
업데이트됨: 5월 22, 2026
ID: 000247770
All products: Contaminants such as dust on fiber optic connector end face causes poor IO performance
Dust or chemical contamination at the endface of a fiber optic LC connector or transceiver module impedes signaling. Dell engineering teams have verified cases in which a fully functional port appears to be a bad port because dirty optical connectors manifest as a port failing loop testing with acceptable power measurement levels. Cable connectors should be cleaned and when stored must be protected from dust particle or chemical contamination.
업데이트됨: 5월 22, 2026
ID: 000246018
ESXi 8.0 U3 설치 중에 시스템 응답 중지 또는 PSOD(Purple Screen Of Death)가 표시됨
업데이트됨: 5월 21, 2026
ID: 000241608
iDRAC Service Module (iSM) 5.4 and older versions fail to upload SupportAssist collections back to Dell. A "handshake API" error occurs. This upload feature has been deprecated due to the receiving servers at Dell had been decommissioned.
업데이트됨: 5월 21, 2026
ID: 000240336