本文详细介绍了在 PowerEdge 服务器上可能会出现的电源装置 (PSU) 问题的故障排除步骤。
更新: 三月 16, 2026
ID: 000127944
了解 PowerEdge 硬盘驱动器、RAID、PowerEdge RAID 控制器和其他存储硬件(如线缆、背板等)并对其进行故障处理。
更新: 三月 14, 2026
ID: 000110444
This KB is to provide information about Dell customized VMware ESXi support stance on the Dell 17th generation of PowerEdge servers. The 17th generation of PowerEdge servers is based on Intel® Xeon® 6500P/6700P (Granite Rapids SP) and AMD EPYC™ 9005 Series Processor (Turin).
更新: 三月 17, 2026
ID: 000334057
Dell Micron 7450 and 7500 Non-Volatile Memory Express solid state drives may encounter drive initialization failure due to a firmware issue, resulting in the solid state drives being unrecoverable.
更新: 三月 17, 2026
ID: 000368482
This article provides information about Intermittent High Fan Speeds on Dell 17G PowerEdge Servers with NVIDIA ConnectX-6 OCP Cards installed.
更新: 三月 16, 2026
ID: 000334522
本文档重点介绍 Dell Technologies PowerEdge 产品的最低代码版本、建议代码版本和最新版本。我们会仔细评估和监控代码部署数据,以确保产品版本符合我们严格的期望,为客户提供可靠的产品和解决方案。
更新: 三月 16, 2026
ID: 000227230
Dell PowerEdge Server remediation is available for a Tianocore EDK2 Vulnerability that could be exploited by malicious users to compromise the affected systems.
更新: 三月 16, 2026
ID: 000440351
本文介绍禁用或限制 iDRAC Direct 功能的 iDRAC 和 BIOS 设置
更新: 三月 16, 2026
ID: 000434735
本文概述了使用生命周期控制器准备系统以进行报废或重新调整用途所需的操作。
更新: 三月 14, 2026
ID: 000198190
本文可帮助您在戴尔支持站点上找到并下载较旧版本的适用于 ESXI 的戴尔自定义 ISO。
更新: 三月 14, 2026
ID: 000238184
Seagate Skybolt and SkyboltServoBP drive fails with medium format corrupted errors.
更新: 三月 13, 2026
ID: 000227930
本文提供了背板硬盘 LED 指示灯的说明。
更新: 三月 13, 2026
ID: 000413096
如果元数据格式大小未设置为 0,PowerEdge 服务器不支持操作系统安装或从直接连接 CPU 的 NVMe SSD 驱动器启动。
更新: 三月 13, 2026
ID: 000417881
报告显示配备 NVIDIA H100NVL GPU 和桥接的 R760XA 上的 NVLink 故障,18 条链路中有 12 条处于活动状态;由于最高 DCGM 版本 3.1.3.1 中的问题,备用链路被错误地标识为关闭。
更新: 三月 13, 2026
ID: 000420594
运行固件版本 xx.46.1006 的 NVIDIA 适配器(ConnectX NIC 和 DPU)可能会遇到 NC-SI 通信故障,从而导致 iDRAC 和 Redfish 等管理工具中的设备报告错误和可见性问题。
更新: 三月 13, 2026
ID: 000399996
PowerEdge:针对 2.5“ 15k RPM SAS 硬盘行业停产的戴尔服务支持
更新: 三月 13, 2026
ID: 000314166
Dell PowerEdge 第 17 代服务器:Delta 电源 (PSU) 存在导致 PSU 不匹配的罕见问题。
更新: 三月 13, 2026
ID: 000328861
Dell Enterprise NVMe 固态硬盘可用作 Dell Data Center NVMe 固态硬盘的替代品。
更新: 三月 13, 2026
ID: 000315161
On Dell PowerEdge 17G servers using Broadcom 5719 QP OCP NX1 cards (DPN M2PYY), firmware installation fails when Secure Boot is enabled on SUSE Linux Enterprise Server (SLES).
Additionally, the installed firmware version is not detected by the Operating System (OS). Disabling Secure Boot allows the firmware to install and be detected correctly.
更新: 三月 11, 2026
ID: 000388249
Dell PowerEdge Server remediation is available for NVIDIA Bluefield, ConnectX and DOCA vulnerabilities that could be exploited by malicious users to compromise the affected systems.
更新: 三月 11, 2026
ID: 000433020
文章介绍了PowerEdge服务器如何通过Linux系统更新硬盘固件-针对于ET005111。
更新: 三月 11, 2026
ID: 000240088
文章介绍了 PowerEdge 服务器开机卡在 POST has been paused 界面这一问题的解决方案。
更新: 三月 11, 2026
ID: 000215475
This article explains different methods to reset, power drain or perform a virtual AC cycle.
更新: 三月 11, 2026
ID: 000175625
This article provides information about key capabilities of Dell PowerEdge Rack and Tower servers, the types of servers offered based on usage purposes, and a brief introduction to the Systems Management tools to discover, manage, monitor, and upgrade server components.
更新: 三月 10, 2026
ID: 000203855
本文章提供BIOS设置中的引导模式选择和启动项顺序更改方法。引导模式选择提供了选项来指定引导模式(BIOS或者UEFI)。
更新: 三月 10, 2026
ID: 000191847
PowerEdge RAID 控制器(PERC11、PERC10)、人机接口基础架构 (HII) 配置实用程序和 iDRAC 不支持阵列扩展。
更新: 三月 10, 2026
ID: 000203958
Dell PowerEdge Server remediation is available for 2025.3 Intel Platform Update (IPU) components that could be exploited by malicious users to compromise the affected systems.
更新: 三月 10, 2026
ID: 000364913
本文介绍如何解决错误“系统在您的计算机上发现了问题,无法继续。无法还原系统配置。检测到安全违规”。紫屏/紫屏死机 (PSOD)
更新: 三月 09, 2026
ID: 000436068
本文章提供Dell 14G/15G PowerEdge服务器上的Full Power Cycle功能
更新: 三月 06, 2026
ID: 000208997
本文提供 PowerEdge 服务器的不能通电、无法开机自检、无法启动和无视频问题的故障处理方法。这包括刀片式、机架式和塔式服务器。
更新: 三月 06, 2026