跳转至主要内容
获得完全访问权限。
登录
创建账户
获得完全访问权限。
登录
创建账户
PowerFlex custom node image

PowerFlex custom node

PowerFlex custom node

文章

输入无效。请仅使用字母、数字和除 <>)(%/;,=#-/* 之外的任何特殊字符

已显示 30 个,共 285 个
已显示 285 个,共 285 个

本文包含有关 Dell Technologies VNX 和 VNXe 产品的客户可更换部件 (CRU) 视频的信息。
更新:  三月 04, 2026 ID: 000262248

戴尔为我们的许多硬件系统提供了客户可更换部件 (CRU) 计划。CRU 计划允许客户更换指定的硬件组件。有关为特定硬件系统指定为 CRU 的硬件组件的列表,请转至戴尔保修和维护页面。
更新:  二月 16, 2026 ID: 000187496

ScaleIO: While applying for a license getting Error: MDM failed command. Status: The current system configuration exceeds the license entitlements.
更新:  四月 17, 2026 ID: 000052096

The MDM reports device errors from an SDS, but the SDS or DAX device in question is being used by the cluster and is healthy.
更新:  四月 17, 2026 ID: 000049265

This article includes procedures for preparing and maintaining a node in an integrated PowerFlex management (non-KVM)
更新:  四月 17, 2026 ID: 000453472

This procedure covers how to perform a graceful reboot on a management node. This process ensures that the PowerFlex Management Platform (PFMP) stays running throughout the process. Maintenance is performed on one Management node at a time. In the scope of this procedure, MVM1 is the postgres Leader. It is drained and rebooted last.
更新:  四月 16, 2026 ID: 000225550

PowerFlex 网关安全套接字层 (SSL) 证书每 90 天到期一次。这会影响使用此证书的 Container Storage Interface (CSI) Driver for PowerFlex 部署。
更新:  四月 13, 2026 ID: 000226935

尝试升级 PowerFlex 生产或 MDS 网关资源失败,指出它无法连接到特定 IP 地址上的 LIA。
更新:  四月 13, 2026 ID: 000220304

所有 PowerFlex 节点的日期和时间都需要与 MVM 同步,mTLS 才能正常工作。
更新:  四月 13, 2026 ID: 000438823

Explore the Dell End of Service Life (EOSL) and End of Life (EOL) list for converged infrastructure, storage, and storage networking products. Access End-of-Life documents for hardware, software, and firmware release and service dates
更新:  四月 10, 2026 ID: 000185734

本文介绍了预测性驱动器故障(错误代码 PDR16)的含义、发生原因,并提供了故障排除和解决问题的逐步说明。它涵盖了建议的操作,例如备份数据、更新固件和更换磁盘(如有必要),以确保存储运行状况并防止数据丢失。
更新:  四月 10, 2026 ID: 000126418

This article explains the different reasons hard drives can fail in detail.
更新:  四月 08, 2026 ID: 000064317

Spontaneous reboot with error "The System board BP1 PG voltage is outside of range"
更新:  四月 07, 2026 ID: 000035374

无法应用 PowerFlex 许可证,收到错误代码 ASMCOMMONS.0070。
更新:  三月 23, 2026 ID: 000227818

从 PowerFlex Manager 平台 (PFMP) 申请许可证失败,并显示错误“许可证密钥无效或与此版本不匹配 (ASMCOMMONS.0049)”。
更新:  三月 23, 2026 ID: 000221565

Dell VxFlex Ready Node and PowerFlex Custom Node remediation is available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.
更新:  三月 17, 2026 ID: 000303519

Dell VxFlex Ready Node and PowerFlex Custom Node remediation is available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.
更新:  三月 17, 2026 ID: 000334768

本文将指导解决 MDS Powerflex 系统中由于缺少 MDM IP 地址(如 MDM 上的 MDS kubectl 日志和 LIA 日志所示)导致的清点问题。
更新:  三月 13, 2026 ID: 000220860

Since the introduction of Clustered VMDK on VMFS datastores, applications like Windows Server Failover Cluster (WSFC) no longer require Raw Device Mappings (RDMs) to use SCSI‑3 persistent reservations (SCSI3‑PR). Because of this, Broadcom does not offer RDM support for the NVMeoF protocol. Customers using RDMs with the SDC who want to move to NVMe/TCP must convert those disks to VMDKs on a VMFS datastore with the Clustered VMDK property. This conversion cannot be done with Storage vMotion, so applications such as WSFC will incur downtime. This KB explains how to perform the WSFC conversion at a high-level. It also covers converting an Oracle RAC environment from RDMs to shared VMDKs on NVMe/TCP, even though Oracle RAC does not require SCSI3‑PR. Oracle RAC can run on an SDC‑based VMFS datastore, but because PowerFlex does not support Clustered VMDK on SDC‑based VMFS, SCSI3‑PR‑dependent applications cannot use that configuration. Oracle RAC explanations are also high-level.
更新:  三月 10, 2026 ID: 000417124

PowerFlex Open Manage Enterprise (OpenManage Enterprise) 允许 PowerFlex 解决方案从节点收集遥测。本文列出了:支持的版本、文档、功能和特性资源以及 AIOps 支持的版本和文档。
更新:  三月 09, 2026 ID: 000412301

文件页面不会加载 NAS 服务器或 FS 详细信息,并以连接丢失状态结束。
更新:  三月 04, 2026 ID: 000202111

通过网关切换 MDM 所有权的 RestAPI 调用失败,并显示超时。
更新:  二月 23, 2026 ID: 000196837

本文详细介绍了在 ESXi 上未启用安全启动时在 TPM 上启用 ESXi 警报抑制的分步过程。
更新:  二月 18, 2026 ID: 000312040

在复制初始拷贝期间,卷传输的大小可能会报告为实际卷大小的 5-10 倍。
更新:  二月 15, 2026 ID: 000261389

在 PFxM UI 中,有一个警报,指出未检索来自 MDM 的事件。
更新:  二月 15, 2026 ID: 000221796

正常导航期间,UI 页面加载缓慢。
更新:  二月 06, 2026 ID: 000412335

本文介绍在触发 Dial Home (DH) SIO03.02.0000005 时,如何从 PowerFlex Manager 平台 (PFMP) 清除设备错误。
更新:  一月 28, 2026 ID: 000256801

本文介绍如何将内部 HTTP 共享用于 4.x PowerFlex Manager 版本认证矩阵 (RCM)、Intelligent Catalog (IC) 和 ISO 上传。
更新:  一月 28, 2026 ID: 000220681

PowerFlex CLI(SCLI 或命令行界面)作为 (Meta Data Manager (MDM)组件的一部分进行安装。PowerFlex CLI 适用于希望使用脚本中的命令自动执行日常任务的用户。登录到 SCLI 使用基于相互传输层安全性 (mTLS) 证书的登录。默认情况下,用于身份验证的证书是 /opt/emc/scaleio/mdm/cfg/mgmt_ca.pem 文件。与 PowerFlex 3.x 不同,用户名和密码与 PowerFlex 管理平台 (PFMP) WEB UI 相同。
更新:  一月 23, 2026 ID: 000350923

本文将介绍如何在 PowerFlex Manager 中删除 VLAN 或更改网络。
更新:  一月 23, 2026 ID: 000350685