文章
输入无效。请仅使用字母、数字和除 <>)(%/;,=#-/* 之外的任何特殊字符
已显示 30 个,共 1105 个
已显示 1105 个,共 1105 个
本文提供了 PowerFlex 软件文档的链接。
更新: 五月 13, 2026
ID: 000307994
本文提供了 PowerFlex 机架、PowerFlex 设备、PowerFlex 自定义节点、VxFlex 就绪型节点、PowerFlex 软件、PowerFlex for AWS、PowerFlex for Azure 和 CloudLink 的文档链接。
更新: 五月 13, 2026
ID: 000308007
夏令时已更改,导致无法访问 UI
更新: 五月 15, 2026
ID: 000252378
This section provides the PowerFlex Manager 3.X compatibility details for PowerFlex rack components.
更新: 五月 15, 2026
ID: 000251318
This procedure describes how to add another IP address subnet for use by the MDM cluster. This addresses scenarios where the MDM cluster uses a single network, or when an existing network must be replaced by a different one or to simply add another network (to an already multiple-network cluster). The MDM supports up to eight networks.
更新: 五月 15, 2026
ID: 000249617
清除设备错误。
更新: 五月 15, 2026
ID: 000249350
在配置了 NVMe 设备的基于 Linux 或基于 ESXi 的 SVM 服务器 PowerFlex 系统中检索操作系统设备路径。
更新: 五月 15, 2026
ID: 000249349
Retrieve the OS device path for a specific virtual drive (VD) in a Linux-based, Windows, or ESXi running PERCCLI server PowerFlex system with an H730p/H740p controller.
更新: 五月 15, 2026
ID: 000249346
Retrieve the OS device paths in a Linux-based or ESXi based Storage Virtual Machine (SVM) server PowerFlex system with an HBA330 controller.
更新: 五月 15, 2026
ID: 000249342
Configure network throttling to control the flow of traffic over the network.
更新: 五月 15, 2026
ID: 000249325
尝试将现有 HCI 资源组重新添加到 PowerFlex Manager 时,客户可能会遇到静态路由配置错误。此问题会阻止成功添加资源组,并可能阻止计划内升级
更新: 五月 15, 2026
ID: 000249264
get_info.sh - collect diagnostic information from a PowerFlex host and pack it into a support bundle
更新: 五月 15, 2026
ID: 000455324
After MDM switchover, SDSs cannot reconnect and MDMs crash.
更新: 五月 15, 2026
ID: 000203272
SDS gets decoupled - the system might experience DU occasionally if more than one SDS decouples concurrently or in case the SDS decouples during a rebuild.
更新: 五月 15, 2026
ID: 000203252
When a vMotion clone of a VM guest is submitted, it takes a lot longer than expected.
Scenario
Due to an environmental configuration issue, there was contention on the vMotion configured NICs that conflicted with iSCSI and VxFlex SDC traffic, causing reduced performance.
更新: 五月 15, 2026
ID: 000203240
SDS fails to start up.
更新: 五月 15, 2026
ID: 000203235
重新启动 ESXi/SVM 后,SDS 会启动,但在 UI/CLI 中处于断开连接状态。
更新: 五月 15, 2026
ID: 000203234
After following NDU flow and switching to 1_node MDM cluster, upgrading Secondary/TB MDMs and trying to put the back into the cluster, MDM throws an error.
更新: 五月 15, 2026
ID: 000203063
Upgrade will not start/finish the Finalize step, since the MDM is shown in an upgrade state in progress.
更新: 五月 15, 2026
ID: 000203061
When trying to create and map a volume to a Compute Node in OpenStack the operation is taking much more time (comparing to the other nodes) and the client is logging errors against the newly created device.
更新: 五月 15, 2026
ID: 000203060
网络连接问题导致辅助 MDM 状态变为“Not synchronized”。
更新: 五月 15, 2026
ID: 000203059
There is only one SDC that is having issues w/ performance.
更新: 五月 15, 2026
ID: 000203058
SDS reports sockets closed without any network events or evidence of networking issues.
更新: 五月 15, 2026
ID: 000203040
每当重新启动 SDC 时都会出现错误。PowerFlex 网关的 IO 超时。
更新: 五月 15, 2026
ID: 000203037
Issue Description
vSphere ESXi hosts hang and become inaccessible randomly after experiencing high latency within the datastores.
更新: 五月 15, 2026
ID: 000203027
Issue Description
Each SDS requires what appears to be a full rebuild when exiting maintenance mode.
更新: 五月 15, 2026
ID: 000203026
在 ESXi v7.x 上运行的 SDC 上使用 Installation Manager(网关)收集日志超时并失败。
更新: 五月 15, 2026
ID: 000203020
Applications that are using PowerFlex volumes are reporting corruption when RMcache is enabled.
更新: 五月 15, 2026
ID: 000202877
Unable to add dax device to an SDS node.
更新: 五月 15, 2026
ID: 000202755
In PowerFlex Manager 4.0, performing a Linux Compute Only deployment using a SLES 15 SP3 ISO gets stuck during the OS installation phase.
更新: 五月 15, 2026
ID: 000202410